ZMI
_001_
2000
1038
00-A
Q
CT0031
_#SDE
_#AQ
U
_#V
2_EN.
fm
- 10 -
18. Setting Cleaning Switch-off
Cleaning switch-off can be set either with the remote control (not included, see
Accessories
) or it can be activated directly on the fitting.
Cleaning switch-off on the fitting
18.1
Allow your hand to approach the sensor at a distance of about 10 cm for 3 seconds.
18.2
Move your hand away from the sensor detection range between the 3rd and 5th
flash of the LED.
• LED does not flash.
18.3
After 3 to 10 seconds, allow your hand to approach the sensor again at a distance of
approx. 10 cm.
18.4
After the third LED flash, move your hand back out of the sensor detection range.
• The fitting is switched off for 3 minutes.
• The LED flashes with a 10 second cycle.
☞
When you allow your hand to approach the sensor at a distance of about 10 cm for
at least 3 seconds, the fitting is reactivated before the end of 3 minutes.
19. Maintenance and Servicing
Depending on the quality of the water, the local conditions and the rules and regula-
tions applicable on site, the fitting must be maintained and serviced at regular
intervals.
Perform maintenance on the following components:
• Filters (see
Properly use suitable cleaning agents that are not harmful to the fittings and rinse
with water after use. High-pressure cleaners must not be used for cleaning.
Removing the shower panel
Some maintenance work requires that the shower panel must be removed.
Caution!
Never let the shower panel hang by the connecting hoses.
!