ZMI
_001_
2000
1038
00-A
Q
CT0031
_#SDE
_#AQ
U
_#V
2_EN.
fm
- 12 -
21. Cleaning the Jet Plate
21.1
Loosen the screw with a hollow hexagon wrench.
21.2
Using a screwdriver, carefully lift out the jet plate.
21.3
Clean the jet-plate.
21.4
Reassemble in the reverse order.
22. Replacing the Filter
Filters in water volume regulator
22.1
Remove the shower panel (see
22.2
Unscrew the locking screw (a) on the flow volume regulator.
22.3
Replace the filter (b).
☞
Important!
Be careful to insert the grit filters the right way round.
22.4
Reassemble in the reverse order.
23. Replacing the Flow Rate Regulator
23.1
Loosen the grub screw using an Allen key.
23.2
Pull the shower head from the connection spigot.
23.3
Remove the circlip with an appropriate pliers for inward circlips.
23.4
Pull out the flow rate regulator with a flat nose pliers.
23.5
Replace the flow rate regulator. Note details provided in the table.
☞
Important!
Ensure correct installation position of the flow rate controller. The brace must face in
the direction of the head piece.
23.6
Insert the flow rate regulator and secure with the circlip.
a: Brace
b: Direction of flow
23.7
Reassemble in the reverse order.
Flow rate
Flow rate regulator
0.15 l/s (orange)
FAR Order No. 2000104782
0.20 l/s (red)
FAR Order No. 2000104783