6
ZMI
_001_
2000
1037
93-A
Q
CT0025
_#SE
N
_#AQ
U
_#V
1.f
m
7. Scope of delivery
8. Dimensions
9. Installation example
10. Assembly
Warning!
Only operate the fitting with non-return valves and the specified filters.
Failure to observe this instruction can result in an increased germ load in the
drinking water and thus pose a health or mortality risk.
Warning!
• Operate the product only with safety extra low voltage (SELV). The components
do not have to be earthed.
• Secure the electrical connection with a residual current circuit breaker (RCD).
Failure to observe this instruction can result in death or material damage due to
electric shock or fire, for example.
☞
Important!
Prior to the assembly process, flush the pipework in accordance with DIN 1988.
10.1
Remove the wall protection.
10.2
Use a hexagonal wrench to close the water volume regulators.
a: closed
b: open
☞
Important!
When removing the cap nut, use an open-ended wrench to hold the water volume
regulator (c).
10.3
Remove the flush connector (c).
10.4
Remove the existing seals.
10.5
Insert the solenoid valve (d) with new seals.
10.6
Open the water volume regulators (see
).
10.7
Fit the frame (e) in a horizontal position.
10.8
Where necessary, shorten the spacer sleeves (f) to the distance between the front
edge of the wall unit and the front edge of the tiles.
Simplified drawing without fitting
☞
Important!
The solenoid valve must be connected before the power supply is connected.