background image

09/17 | 

Franke 036865-002

1

A. INSPECTION

Inspect the water cooler, water fountain and cartons for evidence of rough handling and concealed damage. Damage claims should be 

filed with the carrier.

B. TO PUT WATER COOLER AND FOUNTAIN INTO SERVICE

1.  

NOTE:

 Provincial and local plumbing code may prohibit the use of saddle tapping valves for water line connection in some applica-

tions. All connections must conform to applicable plumbing codes.

2.  The KEP8ACSL is composed of a water cooler and a water fountain. The water cooler contains the refrigeration system and is 

always mounted on the right side. This unit can be configured with the water cooler high or low. Refer to the proper roughing in 

drawing for location of plumbing and electrical service.

3.  FLUSH BUILDING WATER SUPPLY BEFORE INSTALLING UNIT.

4.   Install wall hangers as shown on the desired roughing in drawing. Wall hangers are shipped fastened to the backs of the unit. Units 

with factory installed filters have additional instructions on a label inside of the access panel. Read these before installing the unit.

5.   This unit has been factory assembled for right side high installation. 

To convert for right side low installation:

a)   Remove the patch plate from the left side panel of the water cooler and install on the right side panel of the water 

fountain reusing the two mounting screws. The two bottom screws from each side panel may be temporarily removed 

to improve access.

b)   Remove the screws holding the waste drain tubes from the cooler tops. The shorter drain will be used on the water 

cooler and the longer drain will be used on the water fountain. Make sure that the waste drain gaskets are properly 

installed.

6.   Mount the water cooler on the right hanger.
7.   Straighten the inlet “Water In” tube in the water fountain. Mount the water fountain on left side hanger while routing the “Water 

In” tube through the access hole to the water cooler. Remove the plug from the “Drain/Remote Cold Water” connection and insert 

the “Water In” tube.

8.  

All provided waste drain parts for field installation are packed in the water fountain. Assemble the drain per the appro-

priate roughing in drawing. The short leg of the crossover piece will be on the water cooler side. When the unit has an 

internal waste trap, the trap should be wrapped with insulating tape to prevent sweating. The use of the 1 3/4" knockout 

for a waste line is not recommended because of a potential conflict with ADA* toe space requirements. Check with your 

local building code inspector for approval.

9.  Install a shut off valve in water supply line. Remove the strainer from the cooler “Water Supply” tube. Solder 3/8" inlet tube exten-

sion (furnished) with lead free solder to “Water Supply” tube and insert the strainer in open end of extension. Connect extension 

to shut off valve to allow access to strainer for service, this connection should not be a solder or flare joint. To ease removal of the 

strainer, a sheet metal screw may be lightly threaded into the open end.

10. Rotate the fan blade by hand to see that it is free of obstructions.
11. Check the available power supply against the water cooler data plate to assure correct electrical service. This drinking water 

cooler is intended to be connected to a 20A minimum ground fault circuit interrupting (GFCI) device to meet UL requirements. 

Plug power supply cord into wall outlet. The rear most 1 3/8" diameter knockout in the frame bottom is for an externally located 

electrical supply. Make sure the knockout hole edge is smooth and free of any burrs. Use of a Heyco busing #2184 in the knocked 

out hole is recommended in order to prevent damage to the service cord and to close up excess opening around the cord. Route 

the cord so it does not interfere with ADA* space requirements.

12. To fill the cold water tank on the water cooler, open the water supply line shut-off and push any one of the front pushbuttons to 

allow water to flow to the bubbler. 

13. To adjust bubbler stream:
  All pushbutton models are equipped with a cartridge regulator. The KEP8ACSL and KEPACSL have a slot in the shelf below the 

pushbuttons. Insert a screwdriver in this slot to adjust  regulator. Turn adjustment clockwise to increase stream height. To access 

the KEPV8ACSL adjustment, remove the bezel and button from the front of the cooler.

DRINKING FOUNTAIN INSTALLATION

For all universal split level KEP( )ACSL series

Summary of Contents for 2000102904

Page 1: ...untain Assemble the drain per the appro priate roughing in drawing The short leg of the crossover piece will be on the water cooler side When the unit has an internal waste trap the trap should be wra...

Page 2: ...protector which will disconnect the motor from the line in case of an overload E LUBRICATION water cooler This unit is equipped with a hermetically sealed compressor and requires no additional lubrica...

Page 3: ...16 8 HANGER MOUNTING HOLES 4 PLCS ELECTRONIC EYE MODELS ONLY PUSH PAD WATER COOLER AND FOUNTAIN KEPV8ACSL PUSH BUTTON OPTIONAL GLASSFILLER LOCATION WATER COOLER 1 1 4 O D TAILPIECE AIR FLOW 1 1 4 IPS...

Page 4: ...459 21 1 4 540 33 838 ORIFICE 29 5 16 744 27 686 21 1 4 540 13 9 32 337 7 1 16 179 6 7 32 158 1 3 4 44 1 1 4O D TAILPIECE 3 8O D WATER INLET WITH STRAINER 8 1 4 209 38 3 16 970 18 29 32 480 6 152 37 1...

Page 5: ...inking Water Temperature Specifications subject to change without notice 115 VAC 10 1 PH 60 Hertz 35 1 4 W 18 5 8 D 24 29 32 H 84 lbs 8 GPH 1 4 hp 4 4 amps 134a 3 95 OZ 90 F 80 F 50 F SPECIFICATIONS C...

Page 6: ...flat blade screwdriver into the slotted hole as shown The screwdriver will engage the stream height adjuster in the cartridge plunger Turn clockwise to increase stream height or counter clockwise to r...

Page 7: ...control 027040 039 027040 039 Not applicable 23 Relay 036056 003 036056 003 Not applicable 24 Overload 036055 003 036055 003 Not applicable 25 Start capacitor 60 MFD 027956 008 027956 008 Not applica...

Page 8: ...e Kindred Road Midland ON L4R 4K9 Tel 1 855 446 5663 Fax 1 866 227 3050 www franke commercial com 09 17 Franke 036865 002 WIRING DIAGRAM Single KEP __ series Split Level KEP __ series WIRING DIAGRAM D...

Page 9: ...pi ces servant la tuyauterie d vacuation pour installation sur place sont emball es dans la fontaine Assembler la tuyauterie d vacuation selon les indications du dessin de raccordement La partie la pl...

Page 10: ...ET DE LA FONTAINE 1 Fermer le robinet d arriv e d eau 2 R cup rer l eau de vidange dans un contenant 3 D brancher la conduite d alimentation en eau au niveau du tuyau D ARRIV E D EAU du refroidisseur...

Page 11: ...REMPLISSAGE DE VERRE REFROIDISSEUR D EAU EMBOUT DE D E 1 PO COULEMENT D AIR VACUATION DE 1 1 4 IPS EMPLACEMENT OPTIMAL DE LA TUBULURE DE SORTIE 1 25 1 1 2 13 2 ENDROITS NOTES 1 SIPHON ROBINET D ARR T...

Page 12: ...7 1 16 179 6 7 32 158 1 3 4 44 EMBOUT DE D E 11 4 PO ARRIV E D EAU DE D E 3 8 AVEC FILTRE 8 1 4 209 38 3 16 970 18 29 32 480 6 152 37 1 32 941 1 2 13 2 ENDROITS 3 5 16 84 12 3 4 324 2 ENDROITS 6 3 8 1...

Page 13: ...ation Temp rature d eau boire 115 VAC 10 1 PH 60 Hertz 35 1 4 L 18 5 8 P 24 29 32 H 84 lbs 8 GPH 1 4 hp 4 4 amps 134a 3 95 OZ 90 F 80 F 50 F 115 VAC 10 1 PH 60 Hertz 17 5 8 W 18 5 8 D 18 29 32 H 59 lb...

Page 14: ...e 1 8 po dans le trou avec fente tel qu illustr Le tournevis p n tre dans le dispositif de r glage de la hauteur du jet situ dans le plongeur de la cartouche Tourner dans le sens horaire pour augmente...

Page 15: ...issement isol 035469 055 SP 035469 055 SP Ne pas applicable 22 R glage du refroidissement 027040 039 027040 039 Ne pas applicable 23 Relais 036056 003 036056 003 Ne pas applicable 24 Surcharge 036055...

Page 16: ...dred Road Midland ON L4R 4K9 T l 1 855 446 5663 T l copie 1 866 227 3050 www franke commercial com 09 17 Franke 036865 002 SCH MA LECTRIQUE FONTAINE BOIRE WIRING DIAGRAM Single KEP __ series Split Lev...