56
SI30-00004-56/C
Help guide
4125126F/C
02/10/2003
Documents ejected above/below envelope
CAUSES
1. Envelopes incorrectly
loaded
2. Envelope out of
specification
REMEDIES
1. Correctly position the
envelopes in their tray,
see "Loading the
envelopes"
2. See specification
Insufficient moistening
CAUSES
1. Moistening tray empty
2. Wrong envelope selection,
open/closed
3. Dirty moistening brushes
4. Worn moistening brushes
5. Envelope out of specification
6. Poor quality envelope
7. Wrong moistening settings
REMEDIES
1. Fill the moistening tray, see
"Installation and Start-up"
2. Select "SEAL" in the line
"ENVELOPE"
3. Clean the brushes, see
Section "Cleaning"
4. Replace the moistening
brushes, see Section
"Cleaning"
5. Check the specifications
6. Check quality of seal by
sealing the envelope
manually
7. See section "Advanced
Functions"
Jamming
CAUSES
1. Wrong job selected for
application
REMEDIES
1. Select the job
corresponding to your
documents/application