2.8. External / remote tank
Figure 8
•
A barometric fuel tank should not be positionned where
it will be in the direct rays of the sun or adjacent to a
source of intense heat.
•
If the tank is more than 8 ft (2,5 m) higher than the
stove a pressure reducer must be installed on the oil
line (max. working pressure : 300 mbar).
•
If the tank is lower than the stove a lift pump will have
to be utilized.
•
A clearance of 6 “ (15 cm) must be maintained between
the external/remote tank and the stove.
2.9. Pre-utilization check
-
Check that the glasses are not damaged.
-
Check that the door closes correctly.
-
Check that all removable parts (baffle, catalyser, ring,
etc.) are correctly installed.
-
Check that the seals of the smoke-line are in good
condition.
-
Check that the seals of the feed-line are in good
condition.
-
Light the appliance by referring to the operating
instructions.
2.10. Oil flow adjustment
The float regulator has been adjusted at the factory and
should not need further adjustment.
The eventual re-fit must be realized by a qualified
engineer.
If the burner does not work correctly, check possible
causes before readjusting the settings :
-
Chimney draught
-
Fresh air inlet
-
Oil supply.
Minimum speed (# 3, fig. 9) :
-
Set the regulating knob on minimum speed (# 3) and
let the burner run for a few minutes. The flame must
completely cover the bottom of the burner and the
catalyser body must be glowing red hot.
-
If the flame is too small, the stove will soot up
quickly ; increase the flame by turning the setting
screw (# 3) clockwise.
-
If the flame is too high, reduce the flame by turning the
setting screw (# 3) counter clockwise.
Maximum speed (# 2, fig. 9) :
-
Set the regulating knob on maximum speed (# 2) and
let the burner run for a few minutes. The flame must be
shaped like a cone and reach the upper part of the
door.
-
If the flame is too low, increase the flame by turning the
setting screw (# 2) counter clockwise.
-
If the flame is too high, reduce the flame[ by turning the
setting screw (# 2) clockwise.
Figure 8 - Gravity oil supply
Pumped oil supply
1 - Max. 2,5 m
2 - Min. 0,25 m
3 - Tank
4 - Filter
5 - Suction pomp with
reserve and filter
6 - Pipe 3/8 in. O.D.
5
1
2
6
3
1
3
6
4
2
1
2
3
4
5
Figure 9 - Adjustment devices
1 - A d ju s tment of the
draught regulator
2 - Adjustment screw for
high setting
3 - Adjustment screw for
low setting
4 - Safety pressure door
5 - Draught control
Installation instructions
Savoie - ref. 174 08 02 Y
6
Technical manual "1038"
Summary of Contents for Savoie 174 08 02 Y
Page 12: ...Spare parts Savoie ref 174 08 02 Y 12 Technical manual 1038...
Page 13: ...Notes Savoie ref 174 08 02 Y Technical manual 1038 13...
Page 26: ...Figur 16 Reservedeler Reservedeler Savoie Modell 174 08 02 Y 12 Teknisk manual 1038...
Page 27: ...Notes Savoie Modell 174 08 02 Y Teknisk manual 1038 13...