background image

2 - Safety Precautions 

 
 

The following instructions must be adhered to, in order to ensure a safe working environment and 

the safety of the user. 
 

Note: When unpacking or manoeuvring the searchlight into its fixing position, suitable 
lifting points must be used in order to prevent damage to the equipment or personal injury.  

 
 

„

 

Prevent rain, snow, condensation and water droplets from contacting the lamp as this may 
cause bulb failure and possible shattering; 

„

 

Quartz halogen bulbs run with a high internal pressure in excess of atmospheric. Whilst the 
construction is inherently strong, there is a slight risk of the bulb shattering; 

„

 

Never look directly into an illuminated searchlight as this may cause severe damage to 
eyesight. If it is necessary to inspect a lamp whilst in operation, always wear suitable protective 

goggles; 

„

 

Should it be necessary to examine the lamp with the front bezel removed, always use a 

protective shield and wear goggles to ensure a safe working environment; 

„

 

Never attempt to clean a lamp whilst in use; 

„

 

Searchlights get hot. Never touch the unit when lit and always allow 15 to 20 minutes for 
cooling down after turning the searchlight off; 

„

 

Never place anything on or cover the searchlight when in use; 

„

 

Ensure the lamp has cooled sufficiently before removal; 

„

 

If undue force appears necessary to remove the lamp, the equipment should be inspected by a 
competent person or contact the manufacturer; 

„

 

When breaking a lamp for disposal, care must be taken to ensure the glass fragments are 

safely contained. This operation must be performed out of doors in free air. In all 
circumstances refer to the lamp manufacturers instructions packed with the lamp; 

„

 

Due to the vast range of lamps available it may appear possible that more powerful lamps can 
be used in the equipment than for which it was designed. Even when the unit will physically 

accept a higher wattage or voltage lamp, this substitution is not recommended and is 
dangerous. This action will also void any warranties on the equipment. 

 
Always refer to the lamp manufacturers technical data when dealing with lamps. 

 

 
 
 
 
 
 
 

 

Back To Top

Summary of Contents for FR560

Page 1: ...ht Product Reference Number A2474 FR560RC 115 240v 1Kw Manufacturers details Distributor details Francis Searchlights Ltd Union Road Bolton Lancashire BL2 2HJ UK Tel 44 0 1204 558960 Fax 44 0 1204 558...

Page 2: ...ty Precautions 3 Technical Information 4 Unpacking and Installation Instructions 5 Electrical Installation 6 Operating Instructions 7 Fault Finding 8 Maintenance and Servicing 9 Wiring Diagrams Genera...

Page 3: ...ptimum performance and service life The Francis FR range combines features proven over many years service in the most hazardous conditions in both marine and land installations In order to prolong the...

Page 4: ...re a safe working environment Never attempt to clean a lamp whilst in use Searchlights get hot Never touch the unit when lit and always allow 15 to 20 minutes for cooling down after turning the search...

Page 5: ...internal heater Optional Toughened front glass The searchlight also performs to the following optical data 1000 Watt T H Supply voltage 220 240v or 110 115v Peak Beam Candlepower 2 450 000 lux Range 1...

Page 6: ...pply before being installed Installation procedures should be adhered to in order to ensure a safe working environment and reduce the risk of damage or personal injury Preparing the Mounting Position...

Page 7: ...be made in the cable size in order to overcome the voltage drop The following table should be used for indication purposes only Searchlight FR 115v 1Kw 230v 1Kw Cable Size mm Distance Max Distance Ma...

Page 8: ...from the gearbox to junction box provided Cables required to be connected by the customer 5 core 1 5mm cable from the Junction Box to the Control Panel 12 core 0 5mm cable from the Junction Box to the...

Page 9: ...ich it was designed Any modifications to the product should not be undertaken without consulting the manufacturer Setting to Work Safe service in use necessitates the strict observance of the followin...

Page 10: ...orrect power rating and type Check lampholder is in good condition If the contacts show any sign of corrosion replace the lampholder Check the lampholder is in a good dry condition Never allow water t...

Page 11: ...with leads Ammeter Using the equation P VI the approximate power output of the equipment can be calculated in the following way Using the multi meter take a voltage reading Using the ammeter take an...

Page 12: ...amp will have failed The lamp can also be checked for continuity using a multi meter Replace lamp ensuring all precautions and instructions previously outlined in this manual are adhered to Failure of...

Page 13: ...g a proprietary glass cleaner or metal polish Clean the reflector if required Check the reflector mounting gaskets If signs of corrosion or damage are evident replace as necessary Ensure that the lamp...

Page 14: ...ng Diagrams and General Assembly Drawing Number Description C22606 Wiring Diagram 1Kw RC V S 10 Amp A2474 FR560RC 1Kw General Assembly drawing Control Panel Assembly C23604 Junction Box Assembly Back...

Page 15: ......

Page 16: ......

Page 17: ......

Page 18: ...Back To Top...

Page 19: ...V Mount C20281 00 Bellows Motor Gearbox Spares C22403 01 Pan Motor S Assy C22287 00 Tilt Motor C22380 00 Microswitch no leaver C22382 00 Microswitch with leaver C24030 01 I Drive Pan Speed Controller...