background image

„

 

Never touch the quartz bulb with bare hands, as fingerprints will make the glass cloudy 

and cause a severe loss of light. This may also cause recrystallisation and thus 
weaken the bulb material. Should the bulb be inadvertently touched, remove 

fingerprints with methylated spirit and a clean, soft paper towel. The bulb should then 
be wiped with distilled water. NOTE: ALWAYS WEAR MASK AND GLOVES DURING 

CLEANING);

 

 

In all circumstances the lamp manufacturers data should be referred to when dealing with 
lamps. 

 
 

When fitting the lamp: 
 

-

 

Always isolate the equipment from the supply when inserting a lamp; 

-

 

Ensure the circuit is suitably fused; 

-

 

Ensure the lamp is of the correct power rating and type; 

-

 

Check lampholder is in good condition. If the contacts show any sign of corrosion, replace the 

lampholder; 

-

 

Check the lampholder is in a good dry condition. Never allow water to collect in the lamp fitting 

or come into contact with the lamp. 

 

To fit the lamp: 
 

-

 

Loosen all the thumbscrews on the front of the searchlight, remove the bezel and glass and 
store in a safe place; 

-

 

For easier access the light shield/spill ring may be removed by undoing the fasteners; 

-

 

Cut open one end of the protective sleeve surrounding the lamp; 

-

 

Using the sleeve to prevent the fingers coming into contact with the lamp, position the two pins 
above the holes in the lampholder; 

-

 

Gently push the lamp into the lampholder and remove the protective sleeve; 

-

 

Replace the light shield/spill ring and front bezel assembly, ensuring the thumbscrews are 

securely fastened.  

 

 
 

 
 

 
 

 
 

 
 

 
 

 
 

Summary of Contents for FR560

Page 1: ...ht Product Reference Number A2474 FR560RC 115 240v 1Kw Manufacturers details Distributor details Francis Searchlights Ltd Union Road Bolton Lancashire BL2 2HJ UK Tel 44 0 1204 558960 Fax 44 0 1204 558...

Page 2: ...ty Precautions 3 Technical Information 4 Unpacking and Installation Instructions 5 Electrical Installation 6 Operating Instructions 7 Fault Finding 8 Maintenance and Servicing 9 Wiring Diagrams Genera...

Page 3: ...ptimum performance and service life The Francis FR range combines features proven over many years service in the most hazardous conditions in both marine and land installations In order to prolong the...

Page 4: ...re a safe working environment Never attempt to clean a lamp whilst in use Searchlights get hot Never touch the unit when lit and always allow 15 to 20 minutes for cooling down after turning the search...

Page 5: ...internal heater Optional Toughened front glass The searchlight also performs to the following optical data 1000 Watt T H Supply voltage 220 240v or 110 115v Peak Beam Candlepower 2 450 000 lux Range 1...

Page 6: ...pply before being installed Installation procedures should be adhered to in order to ensure a safe working environment and reduce the risk of damage or personal injury Preparing the Mounting Position...

Page 7: ...be made in the cable size in order to overcome the voltage drop The following table should be used for indication purposes only Searchlight FR 115v 1Kw 230v 1Kw Cable Size mm Distance Max Distance Ma...

Page 8: ...from the gearbox to junction box provided Cables required to be connected by the customer 5 core 1 5mm cable from the Junction Box to the Control Panel 12 core 0 5mm cable from the Junction Box to the...

Page 9: ...ich it was designed Any modifications to the product should not be undertaken without consulting the manufacturer Setting to Work Safe service in use necessitates the strict observance of the followin...

Page 10: ...orrect power rating and type Check lampholder is in good condition If the contacts show any sign of corrosion replace the lampholder Check the lampholder is in a good dry condition Never allow water t...

Page 11: ...with leads Ammeter Using the equation P VI the approximate power output of the equipment can be calculated in the following way Using the multi meter take a voltage reading Using the ammeter take an...

Page 12: ...amp will have failed The lamp can also be checked for continuity using a multi meter Replace lamp ensuring all precautions and instructions previously outlined in this manual are adhered to Failure of...

Page 13: ...g a proprietary glass cleaner or metal polish Clean the reflector if required Check the reflector mounting gaskets If signs of corrosion or damage are evident replace as necessary Ensure that the lamp...

Page 14: ...ng Diagrams and General Assembly Drawing Number Description C22606 Wiring Diagram 1Kw RC V S 10 Amp A2474 FR560RC 1Kw General Assembly drawing Control Panel Assembly C23604 Junction Box Assembly Back...

Page 15: ......

Page 16: ......

Page 17: ......

Page 18: ...Back To Top...

Page 19: ...V Mount C20281 00 Bellows Motor Gearbox Spares C22403 01 Pan Motor S Assy C22287 00 Tilt Motor C22380 00 Microswitch no leaver C22382 00 Microswitch with leaver C24030 01 I Drive Pan Speed Controller...

Reviews: