FBUS INTERFACE UNIT (if supplied)
OVERVIEW
Francis Searchlights FBUS data system facilitates control of up to 30 search-
lights from multiple control stations. To provide the required control response
whilst maintaining a low data rate for extended transmission distance, the
FBUS data system involves precisely timed control signals.
The FBUS interface offers a simplified communication interface to the FBUS
data system over a number of different physical layer communication stand-
ards and data rates. The system also facilitates long range communications
over LAN / Internet.
When used with Francis searchlights FBUS Control software the FBUS inter-
face can control networks of lamps over local communication systems or
globally via the internet.
POWER / FBUS CONNECTION
The FBUS interface obtains a supply from the FBUS data system, no external
power supply is required. The interface connects to the four wire FBUS sys-
tem like any FBUS system component. The four-wire interface provides 24V
supply and RS485 communications with FBUS.
EXTERNAL INTERFACE AND CONNECTIONS
The FBUS interface supports RS422 (4 wire), RS485 (2 wire), USB (VCP)
and UDP.
Connections are detailed below; -
RS485
0 Common 0V
+ Data +
- Data
–
RS422
0 Common 0V
Out + Data + out from interface
Out - Data
– out from interface
In + Data + into interface
In - Data
– into interface
USB
Type B Socket
Ethernet (UDP)
RJ45