6 - Operating Instructions
This equipment is designed for use out of doors, in free air. Never place anything on or cover
the searchlight when in use as this may present a hazard.
Switch On
The panel is activated using the PANEL button. This will illuminate brightly when the panel is
active. Alternate operations of the PANEL button will switch the panel on and off.
Lamp Control
When the panel is active pressing the LAMP, button will switch the lamp on or off.
If the control panel is switched off with the PANEL button the lamp will switch off.
Focus Control
The lamp focus can be adjusted using the FOCUS button. Lamp focus will adjust continuously
whilst FOCUS is pressed.
Beam Direction
The beam direction can be adjusted using the joystick when the panel is active. Moving the
joystick left or right will pan the beam clockwise or anticlockwise.
Moving the joystick up or down will move the beam up or down. The speed of movement is
proportional to the movement of the joystick. It is possible to move the beam in both directions
at once by moving the joystick diagonally.
Home
The lamp can be returned to a pre-set home position. By default, this is dead ahead with the
beam level although different positions can be programmed as described below.
To send the lamp to the home position switch the panel off then press the LAMP button.
Set New Home Position
To set a new home position move the lamp to the new desired home position. Switch the panel
off then press the joystick down to its limit and press the lamp button. The current position will
now be the new home position.
Set Motion Limit
(only available when Remote Focus is fitted)
The lamp travel can be limited in either axis and either direction. To set a new limit switch the
panel on and move the lamp to the desired limit position. Switch the panel off then press and
hold the focus button whilst moving the joystick full travel in the direction of the desired limit.
Hold in this position for 4 seconds. For example, to set a limit to the tilt up motion; -