SET PAN ANGLE
For system development and testing, this command sends a move to pan
position command to the currently selected lamp. The pan angle is set using
the arrow keys. Pressing ENT will move the lamp to the displayed angle.
SET TILT ANGLE
For system development and testing, this command sends a move to tilt
position command to the currently selected lamp. The tilt angle is set using
the arrow keys. Pressing ENT will move the lamp to the displayed angle.
FOCUS
For system development and testing, this function is not implemented on all
searchlights. Focus displays the current focus position with a value of 0-100.
A value of 50 should represent the most focused beam with the beam
diverging above and below 50. Note that the value will ascend from 0-100
then reset back to 0. Pressing the arrow up button will operate the focus
motor.
LIMITS
Displays any faults or limit switch activation relating to the selected lamp.
Multiple faults will be displayed sequentially.
LAMP SOFTWARE
Displays the currently selected lamp software version.
LAMP TYPE No
Displays the lamp type number. FBUS Lamp control cards are generic and
are programmed to the correct lamp type during lamp assembly. This setting
facilitates verification of the lamp type setting.
EXT COMMS DATA
Included to aid external interface development. The display bottom line will
show any valid received commands preceded by the lamp number to which
the command is sent. The system also indicates data errors.
FBUS SUPPLY
This just indicates the FBUS supply voltage. FBUS operates at 24V. Values
above 30 or below 18 indicate something is wrong.
NOTE
– The remining menu items can only be selected when
communications is set to UDP.
REMOTE ADDRESS (UDP Only)
A diagnostic tool to display the IP address of the last remote system to
communicate with the FBUS Interface.
The following menu items will select once the system has read the Ethernet
interface parameters.