7. FIRST COMMISSIONING

         

READ CAREFULLY

Before the first commissioning of the RF module curtain, check the following points:

• 

Did you not leave a tool or other object in the unit that could damage it?

• 

The power supply corresponding to the required value and water heating is necessary?

• 

Did you close the curtain properly?

Read the following instructions carefully before connecting the curtain.

8. CONTROLS

8.1 DESCRIPTION OF THE REGULATION AND ITS CONTROLS

Air curtain without heating:

Turn on the curtain by pressing the  

  button on the remote control. As a result, you can use the speed button to increase  

  or 

decrease  

  the ventilation speed. The selected degree is indicated by the illuminated LEDs on the integrated control panel. To 

turn off the curtain, press the  

  button. 

Air curtain with electric heating:

Turn on the curtain by pressing the 

 button on the remote control. As a result, you can use the speed button to increase 

 or 

decrease 

 the ventilation speed. Use the 

 button to select whether to switch the heating on or off. The operation of the fan 

and heater is indicated by the LEDs on the integrated control panel. To turn off the curtain, press the 

 button. One time turns the 

curtain off, activates a cooling function automatically and cools the electric heater for 30 seconds, then automatically turns off. The 
cooling of the current electric heating is indicated by a flashing speed 1 on the integrated panel.

Programming (pairing):

This function is activated 30 seconds after the curtain is turned on (if the curtain was not connected to the front main power sup-
ply). Simultaneously press all four buttons on the control and hold for at least 4 seconds. If the fan 1 and fan 2 speed LEDs flash 
simultaneously, the units are well paired. On the contrary, if the LEDs flash one after the other, the control is already paired or the 
control limit has been reached (maximum 60 curtains per remote control). This function is activated 30 seconds after the curtain 
has just been turned on (if the curtain was not connected to the main power supply before).

Unpairing:

This function is activated 30 seconds after the curtain has just been turned on (if the curtain was not connected to the main
power supply before). Simultaneously press the 

 

 

 buttons and hold for at least 4 seconds. If fan 1 and fan 2 speed LEDs 

flash simultaneously, 
the units are connected. On the contrary, if the LEDs flash one after 
the other, the control was not linked to the electronic system, and therefore it is not necessary to unpair them.

ON/OFF

ON/OFF

ON/OFF

Summary of Contents for Harmony One Evo Series

Page 1: ...Harmony One Evo EN Harmony One Evo 600 Harmony One Evo 900 NT 1583 A 07 2019 ...

Page 2: ...n installation according to this manual the product can be used safely For product evaluation the harmonised standards specified in the current EC Declaration of Conformity have been used To read the full EC Declaration of Conformity in force please visit www france air com This manual contains important instructions and safety instructions To ensure proper operation and user safety read and obser...

Page 3: ...r unpacking check that 1 The designation on the packaging corresponds to the label on the unit heater 2 The unit heater is not damaged The electric unit heater can be used in many different ways Thus it can be placed above the door windows or on the wall For installation please observe the instructions below As this is a heating unit it is necessary to comply with the basic heating rules To calcul...

Page 4: ...t supplied with the deliv ery 4 pieces of M8 screws for fixing not supplied with the delivery 1 Attach the brackets to the wall 2 Screw the unit heater curtain onto the brackets using the screws supplied with the delivery Detail of the connection of the unit heater to the brackets TECHNICAL SUPPORT To install the brackets use the size 5 Allen key READ CAREFULLY Please ensure that the exhaust pipe ...

Page 5: ...nnot be connected with an extension cord The maximum curve of the power cable is 30mm 6 3 CONTROL PANEL Remote control connection The remote control does not need to be adjusted it is supplied pre set by the manufacturer The control is powered by a 12V electric battery LR23A the electric batteries are included with the delivery It is possible to link up to 60 units to one control The perimeter of ...

Page 6: ...ne time turns the curtain off activates a cooling function automatically and cools the electric heater for 30 seconds then automatically turns off The cooling of the current electric heating is indicated by a flashing speed 1 on the integrated panel Programming pairing This function is activated 30 seconds after the curtain is turned on if the curtain was not connected to the front main power sup ...

Page 7: ...ol does not work The air curtain does not receive any control signal from the remote control Check if the batteries are dead Check the polarity of the batteries in the remote control Check if the remote control is too far from the curtain and if there is any signal intervention The heating switches off spontaneously The heater is overheated The electric heater overheats because the air flow is not...

Page 8: ...cessory used Place of installation Serial number Installation conditions including electrical conditions Operating time Detailed error description 10 2 DEACTIVATION OF THE PRODUCT BEFORE DISPOSING OF IT Even old products contain reusable materials Transport this type of material to the secondary material collection centre It is pref erable to allow the product to be disposed of in the specialised ...

Reviews: