background image

 

 27 

 

 

1. 

Setting conditions of this appliance is indicated in tag or data plate. 

 

2. 

Your  appliance  should  be  plugged  in  a  fuse  appropriate  for  electric  power.  If  necessary,  it  is 

recommended that installation is done by authorized service. 

 

3. 

Your  appliance  is  configured  in  accordance  with  electrical  supply  of  220-240V  50/60Hz. 

4. 

If  main  electrical  network  is  different  from  these  values,  contact  with  your  authorized  service. 

5. 

Electrical  connections  of  your  appliance  should  only  be  made  to  the  fuses  having  suitably  wired 

grounding (grounded) system. If no convenient fuse is available in the place where your appliance is to be 
installed, contact with authorized service immediately. Manufacturing firm is not responsible definitely for 
the damages that fuses whose grounding is not made and connected to the appliance can cause.  
6. 

Plug of the appliance should be close  to be accessed easily to the fuse whose grounding is made 

without use of extension cord.   
7. 

Do not allow contacting the power cable of your appliance with hot regions. Similarly, keep away it 

from sharp edges and corners.   
8. 

If feeder cord is damaged, this cord should be replaced either by manufacturer or its service agency 

or same degree qualified personnel in order to hinder a dangerous situation. 

 

9. 

Wrong  electrical  connection  may  give  damage  to  the  appliance.  In  this  case,  your  appliance  will 

remain out of guarantee scope. Electrical connection of your appliance should be done by authorized service. 

 

 
WARNING: 

Before starting any work related with gas installation, turn off gas supply. Risk of explosion. 

1. 

Connect your appliance to gas cock from the shortest way and in a manner to prevent any leakage. 

For safety, the hose used should be maximum 125 cm and minimum 40 cm. 

 

2. 

While making gas leakage control; never use lighter, match, glowing cigarette or similar inflammable 

matter. 
3. 

Apply soap bubble  on connection point. If any leak/leakage  exists, foaming will occur on soaped 

region. 
4. 

If the built-in hob is to be mounted on a cabinet or openable drawer, a heat protection panel having 

15 mm minimum opening should be mounted under the built-in hob. 

For LPG connection. 

For LPG (cylinder) connection, affix metal clamp on the hose coming 
from LPG cylinder. Affix an edge of the hose on hose inlet connector 
behind the appliance by pushing to end through heating the hose in 
boiled water. Afterward, bring the clamp towards end section of the 
hose and tighten it with screwdriver. The gasket and hose inlet 
connector required for connection is as the picture shown below 

NOTE

: The regulator to be affixed on LPG cylinder should have 300 

mms feature. 

7.

 

ELECTRICAL CONNECTION AND SAFETY 

8.

  

GAS CONNECTION AND SAFETY 

Summary of Contents for FBH-S705IWF-RBK

Page 1: ...FBH S705IWF RBK PLIT INCORPORABIL 5 Arzatoare Gaz Duze GPL incluse...

Page 2: ...iunile necesare referitoare la instalarea utilizarea i ntre inerea aparatului Pentru utilizarea corect i n siguran a aparatului v rugam s citi i cu aten ie acest manual de instruc iuni nainte de insta...

Page 3: ...ntre inere i repara iile trebuie efectuate numai de c tre tehnicieni de service autoriza i Lucr rile de instalare i repara iile efectuate de c tre tehnicieni neautoriza i pot genera pericole Nu modifi...

Page 4: ...ul ATEN IE n timpul utiliz rii unui aparat de g tit cu gaz n nc pere sunt generate umiditate c ldur i produse de ardere Asigura i v c buc t ria este bine aerisit mai ales n timpul utiliz rii aparatulu...

Page 5: ...nformitate cu recomand rile produc torului i atunci c nd este necesar 10 Gazul trebuie s aib o ardere corespunz toare Arderea corespunz toare a gazului poate fi identificat dup flac ra albastr f r ntr...

Page 6: ...spectul aparatului dumneavoastr poate diferi de cel prezentat n figurile de mai jos 1 Pozi iile arz toarelor 6 Arz tor mare 2 Suprafa metalic 7 Arz tor pentru wok 3 Butoane de comand 8 Arz tor mare 4...

Page 7: ...5 Arz tor frontal dreapta AVERTISMENT Panoul de comand de mai sus are numai scop ilustrativ Lua i n considerare panoul de control al dispozitivului dumneavoastr AVERTISMENT Conexiunea electric trebuie...

Page 8: ...ctric necorespunz toare poate duce la deteriorarea aparatului n acest caz garan ia produsului devine nul Conexiunea electric a aparatului trebuie efectuat de c tre personal calificat AVERTISMENT naint...

Page 9: ...cord pentru gaze naturale Pentru a conecta furtunul la conducta principal de gaz str nge i piuli a Finaliza i conectarea prin efectuarea unei verific ri n vederea detect rii sc p rilor de gaze Func io...

Page 10: ...i o urubelni cu o dimensiune corespunz toare Pentru func ionare cu GPL roti i urubul n sensul acelor de ceasornic Pentru func ionare cu gaze naturale roti i urubul o tur n sens contrar acelor de ceas...

Page 11: ...erioare ale marginilor plitei Umple i bine cu past de etan are orificiile de la col uri 4 ntoarce i plita cu fa a n sus a eza i o n spa iul din blat i regla i o corespunz tor 5 Prinde i plita de blat...

Page 12: ...ord n cazul mont rii plitei deasupra unui cuptor ncorporat Furtunul de gaz trebuie amplasat astfel nc t acesta s nu ating cuptorul col uri sau muchii ascu ite s nu fie r sucit sau tensionat Efectua i...

Page 13: ...comer Trebuie prev zut un spa iu de siguran ntre produs i pere ii buc t riei sau articolele de mobilier n cazul instal rii unei hote unui sistem de evacuare deasupra aparatului dumneavoastr urma i re...

Page 14: ...n cazul n care gr tarele nu sunt pozi ionate corespunz tor vasele puse pe acestea se pot r sturna 5 Pentru modelele prev zute cu sistem de siguran la aprindere dup efectuarea opera iei de aprindere c...

Page 15: ...de g tit i cea a fl c rii trebuie s se potriveasc Regla i fl c rile astfel nc t s nu dep easc baza recipientului 13 Nu utiliza i pe plit recipiente instabile care pot fi r sturnate cu u urin 14 Nu a e...

Page 16: ...elor din sticl poate duce la spargerea sticlei Nu utiliza i substan e de cur are abrazive sau raclete metalice 5 Nu cur a i produsul cu aparate de cur at cu aburi 6 Cur a i capacele arz toarelor i sup...

Page 17: ...nu este montat corespunz tor Monta i corespunz tor capacul Flac ra se stinge n timpul func ion rii Dispozitivul de supraveghere a fl c rii este nfundat cu corpuri str ine Cur a i dispozitivul de supra...

Page 18: ...turale Arz tor pentru wok 3 5 Duz Duz 0 96 mm 1 40 mm Debit de gaz Debit de gaz 254 g h 0 333 m h Putere Putere 3 50 kW 3 50 kW Arz tor pentru wok 2 5 Duz Duz 0 82 mm 1 15 mm Debit de gaz Debit de gaz...

Page 19: ...fiecare Echipament Electric si Electronic EEE pe care il pune pe piata Acest cost asigura tratarea ulterioara a echipamentelor uzate colectate Din acest motiv odata ce devine deseu produsul EEE poate...

Page 20: ...ntru ob inerea unor derivate precum traduceri transform ri sau adapt ri f r consim m ntul prealabil al companiei NETWORK ONE DISTRIBUTION Copyright 2020 Network One Distribution Toate drepturile rezer...

Page 21: ...20 FBH S705IWF RBK BUILT IN HOB 5 Gas Burners Spare LPG nozzles included...

Page 22: ...e you with all required instructions related to the installation use and maintenance of the appliance In order to operate the unit correctly and safety please read this instruction manual carefully be...

Page 23: ...king surfaces WARNING If the surface is cracked switch off the appliance to avoid the possibility of electric shock Maintenance and repair work should only be carried out by authorized service technic...

Page 24: ...to flames that are caused by oil instead switch the cooker off and cover the pan with its lid or a fire blanket Always position pans over the center of the cooking zone and turn the handles to a safe...

Page 25: ...again 7 All kinds of operations to be performed on gas installation must be performed by authorized and competent people 8 This appliance is adjusted for natural gas NG If you have to use your product...

Page 26: ...and the appearance of your appliance may differ from that shown in the figures below 1 Burner positions 6 Large burner 2 Metal surface 7 Wok burner 3 Control buttons 8 Large burner 4 Small burner 9 C...

Page 27: ...ght burner 10 Front right burner WARNING The control panels above is only for illustration purposes Consider the control panel on your device WARNIG Get electrical connection of your appliance done to...

Page 28: ...inder a dangerous situation 9 Wrong electrical connection may give damage to the appliance In this case your appliance will remain out of guarantee scope Electrical connection of your appliance should...

Page 29: ...ce gasket in the nut at the edge of natural gas connection hose To install the hose on main gas pipe turn the nut Complete the connection by making gas leakage control Transformation from natural gas...

Page 30: ...following picture To adjust flow rate screw use a screwdriver having suitable dimension For LPG turn the screw clockwise For natural gas turn the screw one time counterclockwise At low position length...

Page 31: ...en in package to the sides of lower guard of counter For corners curl paste and increase curls till filling corner gaps 4 Turn built in hob again and align with and place on counter 5 Fasten up your b...

Page 32: ...between wall and built in hob should be 50 mm If Built In Oven Is Placed Under Built in hob Gas pipe should be affixed in a way not to touch the oven below sharp edges and corners not to be pulled in...

Page 33: ...market A safe distance should be left between the product and kitchen walls and furniture If hood aspirator will be installed over your appliance obey to the recommendation of hood aspirator manufactu...

Page 34: ...n Igniting for these models is as follows 4 Pay attention that built in hob grills are placed on built in hob table completely In case of failure about this matter can cause pouring of the materials t...

Page 35: ...unnecessary cleaning 12 The size of the container and the gas flame shall match each other Set gas flames so that they do not extend further than the base of the container 13 Do not use containers tha...

Page 36: ...knife Do not use abrasive scratching acid materials or detergent 3 Following mopping parts of your built in hob with soapy cloth rinse it later rinse well with a soft cloth 4 Clean glass surfaces wit...

Page 37: ...oreign materials Wipe off foreign materials with a cloth Hobs are wet Carefully dry the hobs Flame spreader holes are clogged Clean the flame spreader Noise coming when burning or during ignition Cook...

Page 38: ...11 g h 0 276 m h Power Power 2 90 kW 2 90 kW Semi Rapid burner Injector Injector 0 65 mm 0 97 mm Gas flow Gas flow 124 g h 0 162 m h Power Power 1 70 kW 1 70 kW Auxiliary burner Injector Injector 0 50...

Page 39: ...espective standards These values may differ depending on the use and ambient conditions F R A M is a registered trademark of Network One Distribution SRL Other brands and product names are trademarks...

Reviews: