GENERAL SAFETY NORMS 

 

When installing or servicing the unit, it is necessary to strictly follow the rules reported on this manual, 
to conform to all the specifications of the labels on the unit, and to take any possible precautions of 
the case for workers. 
Pressure  in  refrigerant  circuit  and  electrical  equipment  present  in  the  unit  can  be  hazardous  when 
installing or servicing the unit 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Any intervention on the machine using any instrument must be carried out only 
by a qualified technician. 

The machine is IPX2 and it must be installed according with local norms and laws 
of the place of installation. 

Not observing the rules reported on this manual, and every modification to the 
unit  done  without  explicit  previous  authorisation,  will  cause  the  immediate 
termination of the warranty. 

Attention:  before  every  operation  of  servicing  on  the  unit,  be  sure  that  the 
electric supply is disconnected. 

Never remove front grille or open any part of the 

machine without removing first the socket from the plug.

 

This  machine  has  been  designed  and  manufactured  in  compliance  with  the 
strictest  safety  rules.  Therefore,  pointed  instruments  (screw  drivers,  wool 
needles  or  similar  ones)  are  not  to  be  inserted  in  the  grilles  or  in  any  other 
opening of the panels, especially when it is opened to remove the filter. 

Main supply must be protected with a differential switch.  

Close  to  the  unit  a  switched  electrical  plug  must  be  present,  according  with 
local laws and norms. 

Never modify settings of the safety devices. 

Never sprinkle water over the unit and its electrical components. 

The machine must not be cleaned using water. To clean the machine use a wet 
cloth. 

Remember to disconnect the plug from the socket before.

 

When  the  machine  is  connected  with  a  power  socket,  it  must  be  in  vertical 
position  and  any  rough  move  must  be  avoided  because  it  could  cause  some 
water to come into contact with electrical parts; it is, therefore, recommended 
to remove the plug from the socket before moving around the machine; if any 
water may have been spread on the machine, following some rough handling 
of the same, then, the machine must be turned off and can be started up again 
only after 8 hours. 

Summary of Contents for FSW63 Series

Page 1: ...FSW 63 DEUMIDIFICATORE DA PISCINA SWIMMING POOL DEHUMIDIFIER FSW63 MANUALE TECNICO TECHNICAL MANUAL M FSW63 14 Multilanguage 01 03 2016...

Page 2: ...CK 33 FINS 33 TUBES 33 COMPRESSOR 33 FANS 33 ELECTRIC BOX 34 MICROPROCESSORS 34 Accessories 34 Body machine completely in Inox 34 Electric heaters in inox 2 0 kW 230 1 50 E H 34 Hot water coil H W C n...

Page 3: ...TO THE HIDRAULIC CIRCUIT only for post heating version 42 MAINTENANCE AND PERIODIC CHECKS 42 IMPORTANT WARNINGS 42 AIR FILTER 43 ELECTRICAL CONNECTIONS 44 Generality 44 Main supply connection 44 Remot...

Page 4: ...ctured and distributed according to safety and electro magnetic compatibility of the European Norms and Regulations MACHINES NORMS 2006 42 CE 17 05 2006 SECURITY REGULATIONS FOR LOW TENSION APPLIANCES...

Page 5: ...e machines described in this manual have been designed according to the pertinent CE Norms in conformity with the MACHINES DIRECTIVES cited in the previous paragraph The machines are also complying wi...

Page 6: ...removing first the socket from the plug This machine has been designed and manufactured in compliance with the strictest safety rules Therefore pointed instruments screw drivers wool needles or simila...

Page 7: ...safety signs which must be complied with General hazard Electric shock hazard It must not be used under explosive atmosphere Machine is not designed to be used by people also children whose physical s...

Page 8: ...spacing The best heat transmission is guaranteed by the fin collars that completely cover the tubes FINS They are manufactured by high precision pressing of aluminium aluminium epoxy painted copper o...

Page 9: ...t water coil H W C nominal capacity 2 4 kW This battery can help you in heat the environment of the swimming pool thanks its efficient water hot coil due to the narrow step fins It is possible to assu...

Page 10: ...pacity optional kW 2 2 Nominal Air flow m3 h 600 600 600 600 Available static pressure Pa 40 40 40 40 Refrigerant charge Tipo R410A R410A R410A R410A Defrost type Type Air Air Air HGD Sound pressure l...

Page 11: ...0 8 0 PERFORMANCE TABLES FSW63 CONDENSED WATER AT DIFFERENT ROOM TEMPERATURE AND HUMIDITY CONDITIONS Roomcondition Condensed water Roomcondition Condensed water 10 C 60 10 l 24h 25 C 60 25 l 24 h 10 C...

Page 12: ...FSW units application Operating Table standard units It is strongly recommended to let the units operate within the below reported limits Exceeding these limits it is not granted neither normal opera...

Page 13: ...trol panel To access it disconnect the power supply and after removing the cover unscrew the protective cap with the help of a screwdriver INSPECTION TRANSPORT AND SITE HANDLING INSPECTION After recei...

Page 14: ...wing points when determining the most suitable site for the unit installation location arrangement in order to guarantee adequate air flow no narrow spaces electrical power sup ply location accessibil...

Page 15: ...rt of the machine CLEARANCES Absolute care must be taken to ensure adequate air volume to the air intake and fan discharge and to avoid air recirculation through the unit that will deeply reduce its p...

Page 16: ...ipe It should be always avoided to form a doubble siphon which could obstruct the water flowing with the consequent risk of flooding the area Removing the case in order to insert the pipe and electric...

Page 17: ...areful when operating in their surroundings even if the electric supply is disconnected WARNING The unit should be installed so that maintenance and or repair services be possible The warranty does no...

Page 18: ...unit be sure that the electric supply has been disconnected In the inner side of the unit movable parts are present Be very careful when operating in their surroundings Aluminium coil fins are very s...

Page 19: ...specting the national rules regarding plants This machines series belongs to the electric appliances functioning at low tension 230 V Before every operation on the electric section be sure that the el...

Page 20: ...ties are reduced Also people without experience or knowledge of the machine can t use it People described above can use this machine only if there s someone responsable of their safety which watches t...

Page 21: ...the environment makes the machine works in order to achieve the degree of humidity wanted When the temperature reached by the finned coil is too low the electronic control unit starts a defrost cycle...

Page 22: ...anges and led REMOTE turn on Pay attention that if the humidity is set in cont position machine works not considering the remote control Remote LED lights up when the machine is controlled remotely ON...

Page 23: ...e from 15 C to 32 C After 4 seconds the display stops flashing and the new set temperature is detected by the control unit HOUR COUNTER per visualizzare le ore di funzionamento sufficiente premere il...

Page 24: ...ew points may cause great capacity loss with consequently longer operating periods it is advisable to set humidity values below 60 only if strictly necessary For the machine which has a second condens...

Page 25: ...alarm resets automatically after 210 seconds If the alarm does not reset simultaneously press and SET HOURS for 10 seconds If the problem occurs again call for service HI t Combination of temperature...

Page 26: ...andard version COM 4 F PUMP FAN T1 T2 T3 FLOAT HPS LPS R G A E V PUMP 0209 COMPRESSOR CAPACITOR L N T 234 RC AG 1 JUMP 2 JUMP 1 REMOTE CONTROL OPTIONAL P 3 GENERAC ALARM OPTIONAL REMOVE THE RESPECTIVE...

Page 27: ...T1 T2 T3 FLOAT HPS LPS R G A E V PUMP 0209 COMPRESSOR CAPACITOR L N T 234 RC AG 1 JUMP 2 JUMP 1 REMOTE CONTROL OPTIONAL PUMP OPTIONAL 3 WAY VALVE B A THERMOSTAT OPTIONAL P COM 4 3 GENERAC ALARM OPTION...

Page 28: ...S R G A E V PUMP 0209 COMPRESSOR CAPACITOR L N T 234 RC AG 1 JUMP 2 JUMP 1 GENERAC ALARM OPTIONAL REMOTE CONTROL OPTIONAL REMOVE THE RESPECTIVE BRIDGE IF YOU USE GENERAL ALARM BRIDGE 1 3 REMOTE CONTRO...

Page 29: ...FLOAT HPS LPS R G A E V PUMP 0209 COMPRESSOR CAPACITOR L N T 234 RC AG 1 JUMP 2 JUMP 1 GENERAC ALARM OPTIONAL REMOTE CONTROL OPTIONAL REMOVE THE RESPECTIVE BRIDGE IF YOU USE GENERAL ALARM BRIDGE 1 3...

Page 30: ...FSW 63 FSW63 14 Multilanguage 01 03 2016 55 DIMENSIONALI DIMENSIONAL DRAWINGS...

Page 31: ...FSW63 14 Multilanguage 01 03 2016 56 FSW 63 DUCTED MACHINE It s possible to require a ducted verison of the machine Made By FRAL S r l Carmignano di Br PD Italy www fral it info fral it...

Reviews: