Fraba VITECTOR OSE-C 4024 v5 Original Instructions Manual Download Page 10

 

10 

Original Instructions OSE-C 4024 v5 

Version: 20190604

 

Original Instructions Control Unit 

OSE-C 4024 v5 

About this document 

1.1 

Function 

This  operating  instruction  manual  provides  all 

necessary  information  for  mounting,  start-up,  safe 

operation  and  demounting  of  the control  unit.  The 

instructions  must  be  kept  in  a  readable  condition 

and accessible. 

1.2 

Type key 

This  operating  instruction  manual  applies  to  the 

following type: 

OSE-C 4024 v5 

1.3 

Copyright 

The  company  FRABA  GmbH claims  the  copyright 

on this documentation. It is not allowed to modify, to 

extend, to hand over to a third party and to copy this 

documentation  without  written  approval  by  the 

company  FRABA  GmbH.  Nor  is  any  liability 

assumed for damages resulting from the use of the 

information  contained  herein.  Further,  this 

publication  and  features  described  herein  are 

subject to change without notice. 

1.4 

Advise to User 

All  readers  are  cordially  invited  to  send  us  their 

feedback  and  comments  to  this  operating 

instruction.  You  can  reach  us  by  e-mail  at 

[email protected]

 

2  General safety instructions 

2.1 

Important Informations 

Read  these  instructions  carefully  and  familiarize 

yourself with the device before installing, operating, 

maintaining or demounting it. 

2.2 

Target Group: Authorised Qualified 

Personnel 

All operations described in this operating instruction 

manual  must  be  carried  out  by  trained  specialist 

personnel, authorised by the plant operator only. 

Please  make  sure  that  you  have  read  and 

understood  these  operating  instructions  and  that 

you  know  all  applicable  legislations  regarding 

occupational safety and accident prevention prior to 

installation  and  putting  the  component  into 

operation. 

2.3 

Explanation of the Symbols Used 

 

Warning of a Danger! 

This  symbol  signifies  imminent 

danger to the life and health of people. 

Failure to comply with these warnings 

can  result  in  property  damage  and 

minor  injuries,  as  well  as  serious 

adverse health effects, including life-

threatening injuries. 

 

Warning  of  Dangerous  Electrical 

Voltage! 

Failure to comply with this instruction 

can result in serious injury or death! 

Summary of Contents for VITECTOR OSE-C 4024 v5

Page 1: ...eppelinstra e 2 50667 K ln Germany T 49 221 96213 0 F 49 221 96213 20 www vitector de info vitector de ASIA FRABA Pte Ltd 114 Lavender Street 08 60 CT Hub 2 Singapore 338729 T 65 6514 8880 F 65 6271 1...

Page 2: ...6 Warnung vor Fehlgebrauch 4 2 7 Haftungsausschluss 4 3 Produktbeschreibung 4 3 1 Bestimmung und Gebrauch 4 3 2 Sicherheitskenngr en OSE Sicherheitsschaltleiste 5 3 3 Technische Daten 5 4 Montage 6 4...

Page 3: ...bsanlei tung zu senden Sie erreichen uns per E Mail in Ihrer jeweiligen Region 2 Allgemeine Sicherheitshinweise 2 1 Wichtige Informationen Lesen Sie diese Anweisungen sorgf ltig durch und machen Sie s...

Page 4: ...k nnen durch den Einsatz der Sicherheitsauswer tung Gefahren f r Personen oder Sch den an Maschinen bzw An lagenteilen nicht ausgeschlossen werden 2 7 Haftungsausschluss F r Sch den und Betriebsst run...

Page 5: ...B10d 106 und Nop 1 pro Minute 3 3 Technische Daten Betriebsspannung 24 V DC 20 10 Absicherung Versor gungsspannung 1 A tr ge Leistungsaufnahme 4 W Kontaktbest ckung 2 Sicherheitskontakte Schlie er 1...

Page 6: ...kein Sicherheitsausgang Vor die Ausgangskontakte ist eine Sicherung 4 A tr ge zu schalten 5 3 Klemmenbelegung Betriebsspannung an Klemmen A1 und A2 anlegen R ckstellungskreis schlie en Start Reset Tas...

Page 7: ...Reaktion auf Reset Schaltleiste noch be t tigt Schaltleiste oder Kabelverbindung besch digt Auswertung defekt 6 Wartung 6 1 Wartung der Sicherheitsauswertung Die Sicherheitsfunktion muss monatlich ge...

Page 8: ...8 Originalbetriebsanleitung OSE C 4024 v5 Version 20190604 Originalbetriebsanleitung Auswerteeinheit OSE C 4024 v5 8 Standard Funktionsschaltbild 9 Zeichnung 22 5 mm...

Page 9: ...About Misuse 11 2 7 Exclusion of Liability 11 3 Product Description 11 3 1 Purpose 11 3 2 Safety Classification 12 3 3 Technical Data 12 4 Mounting 13 4 1 General Mouting Instructions 13 4 2 Dimensio...

Page 10: ...back and comments to this operating instruction You can reach us by e mail at info vitector eu 2 General safety instructions 2 1 Important Informations Read these instructions carefully and familiariz...

Page 11: ...or plant components cannot be excluded 2 7 Exclusion of Liability We shall accept no liability for damages and malfunctions resulting from defective mounting or failure to comply with these operating...

Page 12: ...Technical Data Operating Voltage 24 V DC 20 10 Fuse of Power Supply 1 A slow Power Consumption 4 W Contact Configuration 2 normally open safety contacts 1 auxiliary contact Contact Type Forcibly guid...

Page 13: ...fuse 4 A slow must be connected before the output contacts 5 3 Terminal Assignment Switch operating voltage on at terminals A1 and A2 Closing the reset circuit Connect the start reset button to termin...

Page 14: ...ety edge still actuated safety edge or cable connection damaged defective safety monitoring module 6 Maintenance 6 1 Maintenance of the Safety Monitoring Module The safety edge shall be tested annuall...

Page 15: ...Version 20190604 Original Instructions OSE C 4024 v5 15 Original Instructions Control Unit OSE C 4024 v5 8 Standard Operational Diagram 9 Drawing 22 5 mm...

Page 16: ...mauvaise utilisation 18 2 7 Exclusion de responsabilit 18 3 Description du produit 18 3 1 But 18 3 2 Classification de s curit 19 3 3 Donn es techniques 19 4 Montage 20 4 1 Instructions g n rales de...

Page 17: ...mentaires au sujet de ce manuel d utilisation Vous pouvez nous joindre par courrier lectronique info vitector eu 2 Consignes g n rales de s curit 2 1 Informations importantes Lisez attentivement ces i...

Page 18: ...ou aux composants de l installation ne peuvent tre exclus 2 7 Exclusion de responsabilit Nous n accepterons aucune responsabilit pour les dommages et dysfonctionnements r sultant d un montage d fectue...

Page 19: ...on de fonctionnement 24 V DC 20 10 Fusible d alimentation 1 A lent Consommation 4 W Configuration des contacts 2 contacts de s curit normalement ouverts 1 contact auxiliaire Type de contact Relais gui...

Page 20: ...n des connecteurs Tension de service aux bornes A1 and A2 Fermeture du circuit de r initialisation connectez le bouton de d marrage r initialisation aux bornes X2 et X3 R initialisation automatique ce...

Page 21: ...sible toujours activ bord sensible ou connexion de c ble endommag relais de s cu rit d fectueux 6 Maintenance 6 1 Maintenance du relais de contr le Le bord sensible doit tre test visuellement chaque a...

Page 22: ...22 Instructions d Origine OSE C 4024 v5 Version 20190604 Instructions d Origine OSE C 4024 v5 8 Sch ma op rationnel standard 9 Sch ma 22 5 mm...

Page 23: ...Version 20190604 23...

Reviews: