30
Check the condition of the blow-by filter
Proceed only if the engine is not in operation and at low temperature,
in order to prevent the risk of burns.
Unscrew the three fastening screws and remove the blow-by filter
(1) from the tappet cover (3).
Check that the blow-by filter (1) is free from deposits, otherwise
replace it.
Reposition the blow-by filter (1) in its seat on the tappet cover (3).
Inspection of the exhaust duct/s
Visually check that the exhaust system is not blocked or damaged.
Make sure that there is no risk of dangerous fumes within the
machine. Contact the Manufacturer if necessary.
13_072_N
Eliminate the consumables and any materials in
contact with them (for example, filters) in
accordance with current regulations.
The FPT Technical Service Network workshops are
equipped for this purpose.