background image

13

U32-2 FPI Direct Vent Gas Insert

HAMPTON CAST

FACEPLATE INSTALLATION

1) Lay the faceplate panels flat, face down on something soft so they

don't scratch.

2) Attach the side filler brackets to the left and right sides using 3

screws and washer per side.

3) Attach the right and left cast sides to the top using 2 screws per

side.

5) Connect the ON/OFF switch

wires by taking the black and
red wires with the blue female
ends thru the hole provided
and connecting them to the
ON/OFF switch.

6) Connect the fan switch wires

by taking the black and red
wires with the  male ends (in
the grey harness) thru the
hole provided and connect
them with the wire connec-
tors from the fan speed con-
trol.

7) Insert wires into the strain re-

lief and install into switch box
assembly.

Ensure that the top

and sides are

aligned.

4) Use a measuring tape to ensure that the distance between the left

and right side pieces is 28" (711mm).

Switch Box Assembly

Boss on rear left side

piece.

8) Place the switch box assembly over the boss on the rear left side

piece and secure with one screw.

NOTE: Do not install Cast Faceplate when unit is installed into
a Zero Clearance Unit.

28"

9) Tuck the wires into the faceplate to keep

them away from the insert using the clip
provided.  Attach the clip to the rear of the
faceplate to ensure that the wires do not
touch the side of the unit.

10) The power cord should be run behind the

faceplate panel.

INSTALLATION

NOTE: There are filler brackets specifically for each side. The
way to differentiate this is that on the side of the brackets
there are 2 mounting holes. The side where there is a 7/16"
gap from the top of the bracket to the mounting hole, must
face the top.

Summary of Contents for U32-LP2

Page 1: ...er appliance Installation and service must be performed by an authorized installer service agency or the gas supplier FOR YOUR SAFETY What to do if you smell gas Do not try to light any appliance Do n...

Page 2: ...d Home Listed appliance comes factory equipped with a means to secure the unit INFORMATIONFORMOBILE MANUFACTUREDHOMESAFTERFIRSTSALE This FPI product has been tested and listed by Warnock Hersey as a D...

Page 3: ...n For Your Safety 5 Specifications 5 Gas Pressure Testing 5 Installation into a Solid Fuel Burning Fireplace or Factory Built Fireplace 5 General Safety Information 5 Installation Checklist 5 Manufact...

Page 4: ...ned NOTE FPI units are constantly being im proved Check the label on the unit and if there is a difference the label on the unit is the correct one For the State of Massachusetts installation and repa...

Page 5: ...the factory built fireplace NOTE Any alterations made to the listed solid fuel burning factory built fireplace may void the listing of the fireplace Check with your local inspector before com mencing...

Page 6: ...pages 11 and 12 13 Install both louvers flush or bay See pages 11 and 12 14 Install optional remote control or wall ther mostat pages 15 15 Final check Before leaving this unit with the customer the i...

Page 7: ...Air Intake pipe must be attached to the inlet air collar of the termination cap Part Description 948 305 3 Flex 35 ft 946 529 Co linear DV Vertical TerminationCap FLUE LINER INSTALLATION 1 Cut the fl...

Page 8: ...k tabs enough so that you can slide the brick tabs on to the screws easily but that the tabs are secure For the location of the side brick tab screws see diagram 1 5 Remove the brick tabs and slide th...

Page 9: ...8 B 02 45 E 0 2 4 7 INSTALLATION LOG SET INSTALLATION Read the instructions below carefully and refer to the diagrams If logs are broken do not use the unit until they are replaced Broken logs can int...

Page 10: ...res by taking the black and red wires with the male ends in the grey harness and connect them with the wire connectors from the fan speed control 6 Connect the ON OFF switch wires by tak ing the black...

Page 11: ...in the diagram 2 The bottom louver has a hinge that is at tached 2 screws per hinge to the lip on bottom of the unit Diagram 1a STANDARD FLUSH DOOR The standard flush door comes with a black frame To...

Page 12: ...Y DOOR The Bay louvers MUST be used with the Bay glass option The optional Bay door is an overlay on the flush front The standard flush door and glass must remain on the unit Hook the top of the bay d...

Page 13: ...l into switch box assembly Ensure that the top and sides are aligned 4 Use a measuring tape to ensure that the distance between the left and right side pieces is 28 711mm Switch Box Assembly Boss on r...

Page 14: ...p and bottom grills and brackets are different INSTALLATION Note The top louver should be placed with the curved cut out facing up Diagram 1 Diagram 2 Diagram 3 11 Mount the cast faceplate panels onto...

Page 15: ...rn for 15 min to stabilize 3 Check for proper draft CAUTION Any alteration to the product that causes sooting or carboning that results in damage to the exterior facia is not the responsibility of the...

Page 16: ...ion Ensurethatthewiresdonot touch any hot surfaces and are away from sharp edges CAUTION Label all wires prior to disconnectionwhenservicingcon trols Wiring errors can cause im proper and dangerous op...

Page 17: ...stoallowgas thatmayhave accumulated in the main burner compart ment to escape If you do smell gas follow the instructions on the front of this manual If you don t smell gas continue on to the next ste...

Page 18: ...llowing the instructions below exactly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floo...

Page 19: ...reate carbon build up and will alter the unit s perform ance which is not covered under warranty GLASS GASKET If the glass gasket requires replacement use glass gasket Part 936 265 for the Bay Front a...

Page 20: ...ood to the rear firebox wall and lift out 8 Remove the 10 screws holding the Access Panel in place 9 Remove the Fan Air Duct by loosening the 3 screws squeeze the sides together to remove To remove fa...

Page 21: ...severely affect the appliance perform ance 8 Reinstall the 11 hold down screws 9 HookuptheTP TH andTP THwirestothe appropriate connections on the valve 10 Reinstall the burner assembly Note when insta...

Page 22: ...nual 21 420 920 Flush Louvers Set Black Gold 420 922 Flush Louvers Set Black 420 923 Flush Louvers Set Black Steel 25 420 940 Bay Louvers Set Black Gold 420 938 Bay Louvers Set Black 420 942 Bay Louve...

Page 23: ...Orifice Gasket 66 910 038 Pilot Assembly 3 Flame NG 910 039 Pilot Assembly 3 Flame LP 67 PilotHolder 68 W840470 Pilot Assembly Gasket 69 402 935 Log Set 402 572 EmberPackage 70 420 143 Valve Tray Gask...

Page 24: ...f 2 1 2 Extension Knob 910 426 Flame Hi Low 2 1 2 Extension Knob 402 956 Gold Trim Bay Front 402 958 Steel Trim Bay Front 113 422 960 Bay Front Screen Not available as a replacement part BAY FLUSH FRO...

Page 25: ...ate Set Standard Contour with Black Trim 91 Faceplate Side Right Standard 92 Faceplate Top Standard 93 Faceplate Side Left Assy Standard 402 532 Trims Pkg Standard Black 402 950 TrimSetPkg StandardCon...

Page 26: ...n Speed Control 120 V 189 904 733 Knob Black Cast Surround 201 Cast Faceplate Right 202 Cast Faceplate Top 203 Cast Faceplate Left 205 Flush Glass Frame 194 MountingFlange 207 402 981 Cast Grill Set T...

Page 27: ...accredited distributor or agent provided that the defective part be returned to the distributor or agent Transportation Prepaid if requested Exclusions This limited Lifetime Warranty does not extend...

Page 28: ...__________________ Printed in Canada FPI Fireplace Products International Ltd 2003 FPI Hampton and energy are trademarks of FPI Fireplace Products International Ltd FPI fireplaces are designed with re...

Reviews: