background image

Regency Wood Insert & Hearth Heater

4

LISTED FACTORY BUILT FIREPLACE INSERT

CERTIFIED FOR USE IN CANADA AND U.S.A.

MODEL: I3100L

TESTED TO:

ULC 

S628-M93 

 / 

UL 

1482-1998 

ULC 

S627-00 

UL 

737-2000

REPORT 

NO. 

632-323500

      (MAR.1994)

DO NOT REMOVE THIS LABEL

106

COMPONENTS REQUIRED FOR INSTALLATION: 6" (150mm) STAINLESS STEEL LINER.

OPTIONAL COMPONENT: FAN, ELECTRICAL RATING: VOLTS 115, 60 HZ, 0.6 AMPS, SCREEN DOOR

DO NOT REMOVE BRICKS OR MORTAR IN MASONRY FIREPLACE.  FOR USE WITH SOLID WOOD FUEL ONLY.  DO NOT

USE GRATE OR ELEVATE FIRE.  BUILD WOOD FIRE DIRECTLY ON HEARTH.  OPERATE WITH FEED DOOR CLOSED,

OPEN TO FEED FIRE ONLY.  REPLACE GLASS ONLY WITH CERAMIC GLASS (5mm).  INSPECT AND CLEAN CHIMNEY

FREQUENTLY.   UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR RAPIDLY.  DO NOT

OVERFIRE, IF INSERT GLOWS YOU ARE OVER-FIRING.

2007

DATE OF MANUFACTURE

2006

2005

CAUTION

908-343b rev. 11/05

HOT WHILE 

IN 

OPERATION

DO NOT TOUCH.  KEEP

CHILDREN, CLOTHING

AND FURNITURE AWAY.

CONTACT MAY CAUSE

SKIN BURNS. READ ABOVE

INSTRUCTIONS.

Install and use only in accordance with the manufactuerer's installation and operating instructions.  Install and use only in m

asonry

fireplace or factory built fireplace.  Contact local building or fire officials about restrictions and installation inspection 

in your area.

MADE IN CANADA

Manufactured by:

FPI FIREPLACE PRODUCTS

INTERNATIONAL  LTD.

6988 Venture Street

Delta,  BC    V4G 1H4

(Duplicate Serial #)

Minimum Clearances to Combustibles

(Measured from 

insert body)

ADJACENT SIDEWALL

A

)

13"(330mm)

MANTLE

B)

19"(480 mm)

TOP FACING

C

)

18"(455 mm)

SIDE FACING

D

)

6.5"(165mm)

A

G

F

D

B

C

E

AD

JA

CE

NT

SID

EWA

LL

INSTALL ONLY ON A NON-COMBUSTIBLE HEARTH RAISED (F) 1.5"

 

(38mm)

ABOVE AN ADJACENT COMBUSTIBLE FLOOR.  COMBUSTIBLE FLOOR

MUST BE PROTECTED BY NON-COMBUSTIBLE MATERIAL EXTENDING (E)

16" (405mm) TO  FRONT AND (G) 8" (205mm) TO SIDES FROM FUEL

DOOR.

UNITED STATES

 ENVIRONMENTAL  PROTECTION

AGENCY CERTIFIED TO COMPLY

WITH  JULY 1990, PARTICULATE

EMISSION STANDARDS.

J

A

N

FEB

M

A

R

A

P

R

MAY

J

U

N

JUL

AUG

SEPT

OCT

NOV

D

E

C

SAFETY LABEL

This is a copy of the label that accompanies each 

Regency Small Flush Insert 

and 

Large Flush 

Insert

. We have printed a copy of the contents 

here for your review.

LISTED FACTORY BUILT FIREPLACE INSERT

CERTIFIED FOR USE IN CANADA AND U.S.A.

MODEL: I1100S

TESTED TO:

ULC S628-M93  / UL 1482-1998 / ULC S627-00 / UL 737-2000

REPORT 

NO. 

  

 632-3198 

  

(SEPT.1993)

DO NOT REMOVE THIS LABEL

104

A

G

F

D

B

C

E

AD

JA

CE

NT

SID

EWA

LL

COMPONENTS REQUIRED FOR INSTALLATION:   6IN / 150MM STAINLESS STEEL LINER.

OPTIONAL COMPONENT: FAN, ELECTRICAL RATING: VOLTS 115, 60 HZ, 0.6 AMPS, SCREEN DOOR

DO NOT REMOVE BRICKS OR MORTAR IN MASONRY FIREPLACE.  FOR USE WITH SOLID WOOD FUEL ONLY.  DO NOT USE GRATE

OR ELEVATE FIRE.  BUILD WOOD FIRE DIRECTLY ON HEARTH.  OPERATE WITH FEED DOOR CLOSED, OPEN TO FEED FIRE ONLY.

REPLACE GLASS ONLY WITH CERAMIC GLASS (5MM).  INSPECT AND CLEAN CHIMNEY FREQUENTLY.   UNDER CERTAIN

CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR RAPIDLY.  DO NOT OVERFIRE, IF INSERT GLOWS YOU ARE OVER-FIRING.

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS  (MEASURED FROM INSERT BODY)

INSTALL ONLY ON A NON-COMBUSTIBLE HEARTH RAISED (F) 1.5IN / 38MM

ABOVE AN ADJACENT COMBUSTIBLE FLOOR.  COMBUSTIBLE FLOOR MUST

BE PROTECTED BY NON-COMBUSTIBLE MATERIAL EXTENDING

(E) 16 IN / 405MM TO  FRONT AND (G) 8IN / 205MM TO SIDES FROM FUEL

DOOR.

908-306b   10/03

(Duplicate Serial #)

MANUFACTURED BY:

FPI FIREPLACE 

PRODUCTS

INTERNATIONAL LTD.

6988 VENTURE ST.

DELTA,  BC    V4G 1H

4

HOT H

O

T

 WHILE W

H

IL

E

 IN I

N

 OPERATIONO

P

E

R

A

T

IO

N

DO D

O

 NOT N

O

T

 TOUCH. T

O

U

C

H

.  

KEEP K

E

E

P

 CHILDREN,C

H

IL

D

R

E

N

,

CLOTHING C

L

O

T

H

IN

G

 AND A

N

D

 FURNITURE F

U

R

N

IT

U

R

E

 AWAY.A

W

A

Y

.

CONTACT C

O

N

T

A

C

T

 MAY M

A

Y

 CAUSE C

A

U

S

E

 SKIN S

K

IN

 BURNS.B

U

R

N

S

.

READ R

E

A

D

 ABOVE A

B

O

V

E

 I

NSTRUCTIONS.N

S

T

R

U

C

T

IO

N

S

.

CAUTION

ADJACENT SIDEWALL

A

)

15in / 380mm

MANTLE

B)

20in / 510mm

TOP FACING

C

14in / 355 mm

SIDE FACING

D

)

7

.375in / 185mm

INSTALL AND USE ONLY IN ACCORDANCE 

WITH THE MANUFACTURER'S 

INSTALLATION AND OPERATING INSTRUCTIONS. 

 INSTALL AND USE ONLY IN MA

SONRY

FIREPLACE OR FACTORY BUILT FIREPLACE.

CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA.

UNITED STATES ENVIRONMENTAL  PROTECTION

AGENCY CERTIFIED TO COMPLY WITH JULY 1990,

PARTICULATE EMISSION STANDARDS.

 J

A

N

 F

E

B

 M

A

R

APR

M

A

Y

JUN

JUL

A

U

G

SEPT

OCT

N

O

V

DEC

2005

2006

2007

DATE OF MANUFACTURE

MADE IN CANADA

104

NOTE: 

 Regency units are constantly being 

improved.  Check the label on the unit and if 
there is a difference, the label on the unit is 
the correct one.

SAFETY LABEL FOR I1100S AND I3100L

Summary of Contents for Regency H2100

Page 1: ...MODELS H2100 I1100S I3100L WOOD Fireplace Inserts Hearth Heater 06 02 06 Owners Installation Manual Tested by Installer Please complete the details on the back cover and leave this manual with the ho...

Page 2: ...ld you have any questions about your product that are not covered in this manual please contact the REGENCY DEALER in your area Keep those REGENCY FIRES burning SAFETY NOTE If this Insert is not prope...

Page 3: ...Factory Built Fireplace 8 Installation Into a Masonry Fireplace 8 Faceplate and Trim 9 Fan Blower 10 Floor Protection 11 Firebrick Assembly 11 Door Handle 11 Brick Flue Baf e Secondary Air Tube Insta...

Page 4: ...the contents here for your review LISTED FACTORY BUILT FIREPLACE INSERT CERTIFIED FOR USE IN CANADA AND U S A MODEL I1100S TESTED TO ULC S628 M93 UL 1482 1998 ULC S627 00 UL 737 2000 REPORT NO 632 319...

Page 5: ...mm SIDE FACING D 8 5 in 216mm HEARTH EXTENSION DEPTH E 18 in 455 mm HEARTH EXTENSION ELEVATION F 1 5 in 38 mm HEARTH EXTENSION WIDTH G 6 in 150 mm A G F D B C E ADJ AC ENT S I D EWAL L INSTALL ONLY ON...

Page 6: ...installing and using your replace insert Install and use only in accordance with manufacturer s installation and operating instructions 2 Check your local building codes Building Inspection Department...

Page 7: ...inimum Minimum Minimum Unit Side Wall to Top Facing Facing Hearth Hearth Hearth Side to Side to Top to Side Extension Thickness Extension A B C D E F G Small Flush Insert I1100S 15 380mm 20 510mm 14 3...

Page 8: ...created Thegreaterdraftcan decrease problems such as dif cult start ups smoking out the door and dirty glass INSTALLATION INTO A FACTORY BUILT FIREPLACE 1 When installed in a factory built replace a f...

Page 9: ...late top and faceplate trim withtheunitpulledslightlyawayfrom the replace face If this is done be very careful not to disturb the con nector when shifting the unit to its nal position Now that your in...

Page 10: ...in order to prevent any damage to the fan To attach follow the instructions provided with the fan Make sure to install the rubber grommet to the fan housing before it is installed on the insert 1 Rem...

Page 11: ...sert I3100L Small Insert I1100S Hearth Heater H2100M 2 Tilt the rst Baf e Brick down and then slide the2ndBaf eBrickupandback Reposition both baf e bricks at on the air tubes 3 Important push both baf...

Page 12: ...eft baf e brick at on the air tube 4 Important push both baf e bricks so they are tight against the side walls Note When getting the chimney cleaned remove the baf e bricks for access to the ue then r...

Page 13: ...te level WARNING Never build a roaring re in a cold stove Always warm your stove up slowly 5 Once a bed of coals has been established you may adjust the draft control to a low settingtooperatetheuniti...

Page 14: ...Burn insert with draft control wide open for about15minuteseverymorningduringburn ing season This helps to prevent creosote deposits within the heating system 2 Burn insert with draft control wide op...

Page 15: ...ing Handle Large 20 948 102 Spring Handle Small 23 820 235 Flue Brackets Pkg 163 915 I3100L Fan Blower Assembly 170 915 I1100S Fan Blower Assembly 24 910 157 P Blower Fan Motor 25 910 678 Power Cord 1...

Page 16: ...163 Trim Left Oversize 398 Faceplate Side Oversize 399 Faceplate Top Oversize Part Description Faceplate I1100S 170 911 Faceplate Trim Set Regular 185 170 160 Trim Right Regular 186 170 159 Trim Top...

Page 17: ...0 Volts 27 910 142 Fan Thermodisc 28 910 140 Fan Speed Switch HI OFF LOW 3 way 29 910 138 Switch Auto Manual 2 way 30 Grommet Strain Relief 35 120 954 Air Tube Front 36 120 953 Air Tube Rear 37 836 21...

Page 18: ...9 71 802 104 Brick Partial 1 1 4 x 4 x 9 72 802 146 Brick Partial 1 1 4 x 1 3 4 x 9 75 802 139 Brick Partial 1 1 4 x 4 x 8 3 4 76 802 152 Brick Partial 1 1 4 x 2 x 9 78 802 143 Brick Partial 1 1 4 x...

Page 19: ...I will not be liable for results or costs of workmanship from unauthorized service persons or dealers At all times FPI reserves the right to inspect product in the eld which is claimed to be defective...

Page 20: ..._____________________________________________ Printed in Canada Regency replace products are designed with reliability and simplicity in mind In addition our internal QualityAssurance Teamcarefullyins...

Reviews: