 Pull Open                 

Push Closed

INSTALLATION

Side View

Front View

Front View

Hearth Heater (H2100M)

Steel Baffl e

Place the insulation batt on top of the baffl e.  
Make sure that this batt is laying fl at and does 
not obstruct the smoke from getting up the fl ue 
opening. This insulating batt may be wrapped 
in paper for handling purposes and does not 
require removal. Batt hold down weights are 
supplied with the unit and are to be placed on 
the insulation to either side of the fl ame spreader 
as shown in the diagram and at the rear, directly 
in front of the fl ue opening.

Lift the front  end of the baffl e up and over 
the rear of the 
air tube. On 
Hearth Heater 
(H2100M) re-
move center 
tube by slid-
ing it sideways 
fi rst  and  then 
down.

Small Insert I1100S

1)

  If the two air tubes are installed continue on 

to Step 2), if not, follow the instructions below. 
Install the air tube into the holes in the side 
channels. The notch goes on the right hand 
side with the air holes facing toward the door. 
Slide the tube into the left hand side, as far 
as possible and then bring it back into the 
hole on the right hand side until it locks into 
position. If the tube will not slide in easily 
simply use a pair of vise grips or pliers and 
tap it into place with a hammer. A tighter fi t 
will ensure the tube will not move when the 
unit is burning. There are only two air tubes 
in the small units (refer to the diagram in the 
Large Insert I3100L section).

2)

  Slide the left baffl e brick over the front air 

tube and then slide it back over the rear air 
tube.

3) 

Tilt the left baffl e brick up on top of the side 
channel and it will leave enough room to 
position the right baffl e brick in the same 
manner as Step 1) above. Then reposition 
the left baffl e brick fl at on the air tube. 

4)  Important: push both baffl e  bricks  so 

they are tight against the side walls.

Note:  When getting the chimney cleaned, 

remove the baffl e bricks for access 
to the fl ue, then replace them when 
cleaning is completed.

Lift the rear of the baffl e, pivoting it on the air 
tube, until it clears the rear air channel.

Slide the rear of the baffl e on top of the rear 
air channel in front of the locating tabs.  Make 
sure that the insulation is lying fl at and does 
not obstruct the smoke from getting up the fl ue 
opening.  Place hold down weights on top of 
the insulation - one on each side.

DRAFT CONTROL

Before establishing your fi rst fi re, it is important 
that your fully understand the operation of you 
draft control. The draft rod is on the left side of 
the Inserts and it controls the intensity of the fi re 
by increasing or decreasing the amount of air 
allowed into the fi rebox. To increase your draft 
- pull open, and to decrease - push closed.

As well as a primary and glass wash air system, 
the unit has a full secondary draft system that 
allows air to the induction ports at the top of 
the fi rebox, just below the fl ue baffl e.

WARNING:  To build a fi re in ignorance or to 
disregard the informa tion contained in this 
section can cause serious permanent dam-
age to the unit and void your warranty.

SCREEN DOOR

Hook screen to the inside on the right side 
of the fi rebox door opening. Lock in place by 
turning handle.

Back Side of Screen Shown

WARNING

Fireplace Stoves equipped with doors 
should be operated only with doors 
fully closed. If doors are left partly 
open, gas and fl ame may be drawn out 
of the fi replace stove opening, creat-
ing risks from both fi re and smoke.

When operated with doors open the 
manufacturer supplied screen must 
be used.

NOTE:

 The handle must be positioned at 10 

o'clock when closed to avoid the handle from 
getting hot and to ensure the screen stays in 
place.

Handle Lock

Hooks

Handle at 10 o'clock position.

Summary of Contents for Regency H2100

Page 1: ...MODELS H2100 I1100S I3100L WOOD Fireplace Inserts Hearth Heater 06 02 06 Owners Installation Manual Tested by Installer Please complete the details on the back cover and leave this manual with the ho...

Page 2: ...ld you have any questions about your product that are not covered in this manual please contact the REGENCY DEALER in your area Keep those REGENCY FIRES burning SAFETY NOTE If this Insert is not prope...

Page 3: ...Factory Built Fireplace 8 Installation Into a Masonry Fireplace 8 Faceplate and Trim 9 Fan Blower 10 Floor Protection 11 Firebrick Assembly 11 Door Handle 11 Brick Flue Baf e Secondary Air Tube Insta...

Page 4: ...the contents here for your review LISTED FACTORY BUILT FIREPLACE INSERT CERTIFIED FOR USE IN CANADA AND U S A MODEL I1100S TESTED TO ULC S628 M93 UL 1482 1998 ULC S627 00 UL 737 2000 REPORT NO 632 319...

Page 5: ...mm SIDE FACING D 8 5 in 216mm HEARTH EXTENSION DEPTH E 18 in 455 mm HEARTH EXTENSION ELEVATION F 1 5 in 38 mm HEARTH EXTENSION WIDTH G 6 in 150 mm A G F D B C E ADJ AC ENT S I D EWAL L INSTALL ONLY ON...

Page 6: ...installing and using your replace insert Install and use only in accordance with manufacturer s installation and operating instructions 2 Check your local building codes Building Inspection Department...

Page 7: ...inimum Minimum Minimum Unit Side Wall to Top Facing Facing Hearth Hearth Hearth Side to Side to Top to Side Extension Thickness Extension A B C D E F G Small Flush Insert I1100S 15 380mm 20 510mm 14 3...

Page 8: ...created Thegreaterdraftcan decrease problems such as dif cult start ups smoking out the door and dirty glass INSTALLATION INTO A FACTORY BUILT FIREPLACE 1 When installed in a factory built replace a f...

Page 9: ...late top and faceplate trim withtheunitpulledslightlyawayfrom the replace face If this is done be very careful not to disturb the con nector when shifting the unit to its nal position Now that your in...

Page 10: ...in order to prevent any damage to the fan To attach follow the instructions provided with the fan Make sure to install the rubber grommet to the fan housing before it is installed on the insert 1 Rem...

Page 11: ...sert I3100L Small Insert I1100S Hearth Heater H2100M 2 Tilt the rst Baf e Brick down and then slide the2ndBaf eBrickupandback Reposition both baf e bricks at on the air tubes 3 Important push both baf...

Page 12: ...eft baf e brick at on the air tube 4 Important push both baf e bricks so they are tight against the side walls Note When getting the chimney cleaned remove the baf e bricks for access to the ue then r...

Page 13: ...te level WARNING Never build a roaring re in a cold stove Always warm your stove up slowly 5 Once a bed of coals has been established you may adjust the draft control to a low settingtooperatetheuniti...

Page 14: ...Burn insert with draft control wide open for about15minuteseverymorningduringburn ing season This helps to prevent creosote deposits within the heating system 2 Burn insert with draft control wide op...

Page 15: ...ing Handle Large 20 948 102 Spring Handle Small 23 820 235 Flue Brackets Pkg 163 915 I3100L Fan Blower Assembly 170 915 I1100S Fan Blower Assembly 24 910 157 P Blower Fan Motor 25 910 678 Power Cord 1...

Page 16: ...163 Trim Left Oversize 398 Faceplate Side Oversize 399 Faceplate Top Oversize Part Description Faceplate I1100S 170 911 Faceplate Trim Set Regular 185 170 160 Trim Right Regular 186 170 159 Trim Top...

Page 17: ...0 Volts 27 910 142 Fan Thermodisc 28 910 140 Fan Speed Switch HI OFF LOW 3 way 29 910 138 Switch Auto Manual 2 way 30 Grommet Strain Relief 35 120 954 Air Tube Front 36 120 953 Air Tube Rear 37 836 21...

Page 18: ...9 71 802 104 Brick Partial 1 1 4 x 4 x 9 72 802 146 Brick Partial 1 1 4 x 1 3 4 x 9 75 802 139 Brick Partial 1 1 4 x 4 x 8 3 4 76 802 152 Brick Partial 1 1 4 x 2 x 9 78 802 143 Brick Partial 1 1 4 x...

Page 19: ...I will not be liable for results or costs of workmanship from unauthorized service persons or dealers At all times FPI reserves the right to inspect product in the eld which is claimed to be defective...

Page 20: ..._____________________________________________ Printed in Canada Regency replace products are designed with reliability and simplicity in mind In addition our internal QualityAssurance Teamcarefullyins...

Reviews: