IN-GNC08
- 15 -
© Future Products Group
TROUBLE SHOOTING
FAULT
POSSIBLE CAUSE
REMEDY
Well does not operate/start
The mains isolating switch on
the wall, circuit breaker or fuses
are off at the power board
Turn isolating switch circuit
breaker or fuses on
High condenser temperature
Clean condenser and radiator
The power switch on the cabinet
is OFF
Turn the power switch ON
The power switch is faulty
Have the switch replaced
Well does not reach correct
temperature
External draughts
Eliminate draughts
Air grills not fitted correctly
Ensure vanes are horizontal
Product blocking air grill
Place product on shelves
Fan cover not fitted correctly
Make sure there are no air gaps
Evaporator coil fins blocked
Clean coil fins of food etc.
Trays obstructing air flow
Re-position trays on shelves
Thermostat needs adjustment
Adjust controller
Ambient temperature > 25
C
Adjust room air conditioning
Evaporator coil iced up
De-ice coil
Condenser radiator blocked
Remove dust and debris
Thermostat faulty
Replace controller
Temperature probe damaged
Replace temperature probe
Auto defrost faulty
Have defrost settings checked
Fans not operating
Have fans checked/replaced
Service
Personnel Only
The table entries in
italics
indicate actions to be taken only by qualified Service
Personnel.