Part No. 27221 Rev. G October 2019
- 18 -
5000 Series Open Front Cabinets
Element Failure
HEATED CABINETS
-
SERVICING
Alarm
Indication
In the event of one or more infrared elements failing, or an element shelf plug
becoming dislodged or un-plugged, the Under Current Relay will close the
digital input to the Dixell controller. After one minute the Dixell controller will
display the alarm
“EA”
along
with an audible alarm sound.
The cabinet will continue to operate while alarming. Once the fault is rectified
the alarm is cancelled by turning the cabinet power off.
Correction
First check and ensure that all the element shelf plugs are plugged in correctly.
If a plug is found to be dislodged or un-plugged, insert the plug correctly and
then turn the cabinet power off and back on again. The alarm will be cancelled
and the cabinet should operate normally. If the alarm returns call for service.
Servicing
Locate and replace the faulty element or elements. Turn the cabinet power back
on and check the operation of all elements. The front elements are turned on
with the first cycle time and the rear elements are turned on with the second
cycle time.
Element Replacement
HEATED CABINETS
-
SERVICING
Remove Cover
Plates
Remove the four screws that secure the cover plates on each side of the shelf.
Continued on next page
Summary of Contents for INLINE 5000C Series
Page 1: ...Heated Open front Cabinets Curved and Square Formats...
Page 28: ...Part No 27221 Rev G October 2019 28 5000 Series Open Front Cabinets IN 5H06 5H08 5H12 OF SQ...
Page 29: ...IN 5H06 08 12 OF 29 Future Products Group...
Page 30: ...Part No 27221 Rev G October 2019 30 5000 Series Open Front Cabinets...