IN-5H06/08/12-OF
- 15 -
© Future Products Group
Power Supply
HEATED CABINETS
-
INSTALLATION
Power Supply
Connection
The cabinet is supplied with a three-core
mains lead, with phase, neutral and earth
conductors, fitted with a three-pin plug.
The mains lead is terminated on a connection
block, mounted on the base chassis.
Before connecting to the power supply, check
that the local supply is correct to that shown
on the rating label on the rear of the cabinet.
Electrical
Isolation
An accessible means of isolation must be provided in the electrical supply to the
cabinet.
Earthing
THIS APPLIANCE MUST BE EARTHED/GROUNDED
The cabinet should be earthed via the earth lead in the
mains cable.
In addition, an equipotential earth bonding terminal is
provided, to allow the cabinet to be bonded to a building
surge earth or adjacent equipment.
Mains Lead
HEATED CABINETS
-
INSTALLATION
Lead
Replacement
If damaged, the mains lead must ONLY be replaced by a qualified service
person.