Part No.16894 Rev. G March 2014
- 14 -
3000 Series Cabinets
Setting Up
cont.
BAIN-MARIE CABINETS - INSTALLATION
Isolation
If the cabinet is not connected by a plug and socket, but is hard wired to the
mains supply, a means of isolation must be provided.
If a plug and socket are used, they should still be accessible after the cabinet is
installed.
Location
BAIN-MARIE CABINETS
-
INSTALLATION
Ventilation
The heated cabinet is designed to meet the
HACCP specification with free room air
circulation.
Do not obstruct the vents in the rear top panel.
Access
Access to the back of the cabinet is required for loading, cleaning and operation
of the control panel.
Fumes and
Odours
Before use, operate the cabinet for 4 hours at 90°C, to remove any fumes or
odours, which may be present. Open the doors periodically during this period,
to allow a change of air. This will avoid possible tainting of food.