Foxwell OS100 Digital Oscilloscope User’s Guide_English Version_V1.00

1

Trademarks

FOXWELL is trademark of Shenzhen Foxwell Technology Co., Ltd.

All other marks are trademarks or registered trademarks of their respective holders.

Copyright Information

©2014 Shenzhen Foxwell Technology Co., Ltd.
All rights reserved.

Disclaimer

The information, specifications and illustrations in this manual are based on the latest information

available at the time of printing.
Foxwell reserves the right to make changes at any time without notice.

Visit our website at:

www.foxwelltech.com

For Technical Assistance, send us email at

[email protected]

Summary of Contents for OS100

Page 1: ...ive holders Copyright Information 2014 Shenzhen Foxwell Technology Co Ltd All rights reserved Disclaimer The information specifications and illustrations in this manual are based on the latest information available at the time of printing Foxwell reserves the right to make changes at any time without notice Visit our website at www foxwelltech com For Technical Assistance send us email at support ...

Page 2: ...d or distributed by FOXWELL 3 The customer shall bear the cost of shipping the product to FOXWELL And FOXWELL shall bear the cost of shipping the product back to the customer after the completion of service under this limited warranty 4 FOXWELL does not warrant uninterrupted or error free operation of the product If a problem develops during the limited warranty period the consumer shall take the ...

Page 3: ...LUDING CUSTOMERS AND INJURY TO PROPERTY RESULTING FROM THE PURC HASE OR USE OF THE PRODUCT OR ARISING FROM BREACH OF THE WARRANTY BREACH OF CONTRACT NEGLIGENCE STRICT TORT OR ANY OTHER LEGAL OR EQUITABLE THEORY EVEN IF FOXWELL KNEW OF THE LIKELIHOOD OF SUCH DAMAGES FOXWELL SHALL NOT BE LIABLE FOR DELAY IN RENDERING SERVICE UNDER THE LIMITED WARRANTY OR LOSS OF USE DURING THE PERIOD THAT THE PRODUC...

Page 4: ...ety Instructions And always use your code reader as described in the user s manual and follow all safety messages Do not route the test cable in a manner that would interfere with driving controls Do not exceed voltage limits between inputs specified in this user s manual Always wear ANSI approved goggles to protect your eyes from propelled objects as well as hot or caustic liquids Fuel oil vapors...

Page 5: ...l Oscilloscope User s Guide_English Version_V1 00 5 automatic transmission or neutral for manual transmission And never leave a running engine unattended Do not wear jewelry or loose fitting clothing when working on engine ...

Page 6: ...ccessories 12 1 3 Install Software 13 1 4 Install Driver 15 1 5 General Features 21 1 6 General Check 21 1 7 Function Check 23 1 8 Self Calibration 25 Chapter 2 Operating Basics 25 2 1 The User s Interface 25 2 2 The Menu System 27 2 3 The Vertical System 30 2 4 The Horizontal System 31 2 5 The Trigger System 32 2 6 Input Connector 33 Chapter 3 Oscilloscope Functions 34 3 1 Setup the Oscilloscope ...

Page 7: ...ter 4 Application Example 76 4 1 Simple Measurement 76 4 2 Capturing a Single Shot Signal 77 4 3 The Application of the X Y Operation 77 4 5 Taking Cursor Measurements 79 4 6 Waveform Generator 83 4 6 1 Generate the Sine waveform 83 4 6 2 Generate the Square waveform 84 4 6 3 Generate the AM FM waveform 85 4 6 4 Generate the Ramp waveform 87 4 6 5 Generate the Trapezia waveform 88 4 6 6 Generate t...

Page 8: ...Foxwell OS100 Digital Oscilloscope User s Guide_English Version_V1 00 8 Cleaning 95 ...

Page 9: ...e circuit under test Disconnect the probe input and the probe reference lead from the circuit under test before disconnecting the probe from the measurement device Observe All Terminal Ratings To avoid fire or shock hazard observe all ratings and markings on the product Consult the product manual for further ratings information before making connections to the product Use Proper Probe To avoid sho...

Page 10: ... is ideal for production test research and design and all of the applications involving analog circuits test and troubleshooting as well as education and training In addition to the list of general features on the next page this chapter describes how to do the following tasks System Requirements Install Software Install Driver General Features General Check Function Check Self Calibration Accessor...

Page 11: ...ements Operating System Window XP Vista Win7 Win8 Win10 Processor Upwards of 1 00G processor Memory 256M byte Disk Space 500M disk free space Screen resolution 800 x 600 Recommended Configuration Operating System Win8 Win10 Windows XP SP3 System Processor 2 4G Processor Memory 1G Byte Memory Disk Space 80G Disk Space Screen resolution 1024 x 768 or 1280 x 1024 resolution DPI Setting Normal Size 96...

Page 12: ...ind any of the following items missing from your package contact your local dealer for assistance Item Item Large Dolphin Gator Clip 2 Pcs Auto High pressure Ignition Probe 1Pc Acupuncture Probe Set 1 Pc Multimeter Probe 2 Pcs Auto Test Cable 4 Pcs Attenuator 2 Pcs Break out lead 1 Pc Dolphin Gator Clip cable 2 Pc USB line 1 Pc Software installation CD 1Pc ...

Page 13: ...on CD into the CD ROM drive or to Visit our site http www foxwelltech com support update to click the image of OS100 to download update package 2 The installation should start up automatically Otherwise in Windows Explorer switch to the CD ROM drive or upadate package and run Setup exe 3 The software Installation is started Click Next to continue 4 Choose a destination directory Click Next to cont...

Page 14: ...Foxwell OS100 Digital Oscilloscope User s Guide_English Version_V1 00 14 5 Check the setup information Click Next to start copying of files 6 This Status dialog is displayed during copying of files ...

Page 15: ...xwell OS100 Digital Oscilloscope User s Guide_English Version_V1 00 15 7 The installation is complete 1 4 Install Driver Example Foxwell OS 100 1 Connect the A Type Plug of USB cable to your PC S USB port ...

Page 16: ...oxwell OS100 Digital Oscilloscope User s Guide_English Version_V1 00 16 2 Connect the other A Type Plug of USB cable to the device s USB port 3 New hardware is found 4 Click right mouse and select Manage ...

Page 17: ...Foxwell OS100 Digital Oscilloscope User s Guide_English Version_V1 00 17 5 Click right mouse and select Update Driver Software 6 Select Browse my computer for driver software ...

Page 18: ...Foxwell OS100 Digital Oscilloscope User s Guide_English Version_V1 00 18 7 Select the right driver path click Next 8 Click Install this driver software anyway ...

Page 19: ...Foxwell OS100 Digital Oscilloscope User s Guide_English Version_V1 00 19 9 Installing driver software 10 Foxwell OS 100 USB has been successfully installed ...

Page 20: ...Foxwell OS100 Digital Oscilloscope User s Guide_English Version_V1 00 20 11 After the device driver is installed correctly the device manager is shown as follows ...

Page 21: ... waveform intensity more effective waveform view User interface in several user selectable languages 1 6 General Check Please check the instrument as following steps after receiving an oscilloscope Check the shipping container for damage Keep the damaged shipping container or cushioning material until the contents of the shipment have been checked for completeness and the instrument has been check...

Page 22: ... From the Probe menu select attenuation to 1 10 Set the switch to X10 on the probe and connect it to CH1 of the oscilloscope When using the probe hook tip insert the tip onto the probe firmly to ensure a proper connection Attach the probe tip to the Probe Compensator and the reference lead to the ground connector select CH1 and then press the AUTOSET button into the menu or the toolbar Check the s...

Page 23: ... insulated cable and do not touch the metallic portions of the probe head while it is connected with a voltage source 1 7 Function Check Perform this functional check to verify that your oscilloscope is operating correctly Connect the oscilloscope You should connect the A Type Plug of USB cable to your PC USB port and connect the other A Type Plug of USB cable to oscilloscope USB port Input a sign...

Page 24: ...sert then turn right to lock the probe Finally attach the tip of probe and ground nip to the Connector of Probe compensator 2 Set the CH1 probe attenuation of the oscilloscope to X10 The default is X1 3 Attach the tip of probe and ground nip to the Connector of Probe compensator Click the button A square wave will be displayed within a several seconds Approximately 1 kHz 2V peak to peak 4 Inspect ...

Page 25: ...t twenty minutes to ensure it is warmed up To compensate the signal path disconnect any probes or cables from the input connectors Then access the Utility Calibration option and follow the directions on the screen The self calibration routine takes about several minutes Chapter 2 Operating Basics The User s Interface The Menu System The Vertical System The Horizontal System The Trigger System Inpu...

Page 26: ...ge trigger slope source and level 4 The Horizontal Panel The user can change Time Div format in the panel 5 The Vertical Panel The user can turn on off the CH1 CH2 CH3 CH4 Also the user can change the CH1 CH2 CH3 CH4 volt div coupling and probe attenuation 6 The Trigger Panel In this panel the user can change the trigger mode sweep source and slope 7 Displays the system time 8 Marker shows Edge tr...

Page 27: ...e is no marker the channel is not displayed 13 Marker shows horizontal trigger position 14 Trigger status indicates the following AUTO The oscilloscope is in auto mode and is acquiring waveforms in the absence of triggers Trig D The oscilloscope has seen a trigger and is acquiring the post trigger data STOP The oscilloscope has stopped acquiring waveform data RUN The oscilloscope is running 2 2 Th...

Page 28: ...al Oscilloscope User s Guide_English Version_V1 00 3 Setup Setup setting 4 Display Change wave display type 5 Cursor Set Cursor measure type 6 Measure Set measurement parameters 7 Acquire Run Stop or other operation setting ...

Page 29: ...29 Foxwell OS100 Digital Oscilloscope User s Guide_English Version_V1 00 8 Utility Utility setting 9 Vehicle 10 Window Window setting 11 Help Turn on help file ...

Page 30: ...k Setup Vertical The following figure shows the vertical Setup window It shows the vertical parameters setting 1 Select channel User can select the channel by clicking the Combo box 2 Select channel User can select the channel by clicking the Combo box 3 VOLTS DIV Set the selected channel voltage range ...

Page 31: ...Select one according to the probe attenuation factor to ensure correct vertical scale reading 6 BW Limit Reject the frequency component higher than 20MHz 7 Invert Invert the selected wave 2 4 The Horizontal System Click Setup Horizontal The following figure shows the Horizontal System window It shows the horizontal parameters settings ...

Page 32: ... Guide_English Version_V1 00 1 Time DIV leads the setting of the time base parameters 2 Format leads the setting of the horizontal format parameters 2 5 The Trigger System Click Setup Trigger The following figure shows the trigger system control ...

Page 33: ...the trigger mode 2 Trigger Sweep Selects the trigger sweep mode to AUTO NORMAL or SINGLE 3 Trigger Source Selects the trigger source to CH1 CH2 CH3 CH4 4 Trigger Slope Selects the edge trigger slope to Positive or Negative slope 2 6 Input Connector CH1 CH2 CH3 CH4 Input connectors for waveform display ...

Page 34: ...igger System Save Load Utility Function Measure Signal Zoom In Out Waveforms Acquire Signal Print 3 1 Setup the Oscilloscope Using AUTOSET to display a signal automatically Auto setup functions one time each time you push the AUTOSET button The function obtains a stable waveform display for you It automatically adjusts the vertical scale horizontal scale and trigger settings Auto setup also displa...

Page 35: ...e You can use the Save Setup menu to permanently save up to several different setups Load Setup The oscilloscope can recall the last setup before the oscilloscope software was running any saved setups or the factory setup You can use the Load Setup menu to permanently recall a setup Factory Setup The oscilloscope software is set up for normal operation when it is shipped from the factory This is t...

Page 36: ...ttenuation Invert Turn on off the invert function Change Volt DIV You can click volt Div in vertical Setup window to select the voltage You can also change the selected channel voltage in sidebar You can left click and drag the mouse on the knob to change the voltage Set Channel Coupling Click Coupling in Vertical Setup window In the sidebar you can change the channel coupling too ...

Page 37: ...tenuation setting toggle the probe menu to match the attenuation factor of the probe This setting remains in effect before you changed again Click Probe in Vertical Setup window to select the probe attenuation The probe setting window in the sidebar Note The attenuation factor changes the vertical scale of the oscilloscope so that the measurement results refect the actual voltage levels at the pro...

Page 38: ...et operates type of the math channel Volt DIV Set the resolution of the math channel Probe Set the math channel probe attenuation Invert Turn on off the invert function The mathematic functions include addition subtract multiply and FFT for CH2 Source A B Source A and Source B Menu Operate Four Types A B Add source A and source B A B Subtract source B from source A ...

Page 39: ... the waveform Select the operate type in the Operate menu Select source A and B Then adjust the vertical scale and offset to view the math channel clearly The mathematic result can be measured by the measure and the cursor The Math Function Display Invert The invert function turns the displayed waveform 180 degrees with respect to the ground level When the oscilloscope is triggered on the inverted...

Page 40: ...40 Foxwell OS100 Digital Oscilloscope User s Guide_English Version_V1 00 The following picture shows the waveform of in ...

Page 41: ...form from the rfc file from your computer Save Save the current reference waveform to your computer as rfc format Save Reference Save the current reference waveform to your computer as rfc format You can change the vertical scale of a waveform The waveform display will contract or expand relative to the reference level Load Click Load to load the rfc file that was selected The load file window wil...

Page 42: ...after you selected the saved source The Reference Waveform Display Window Note If you turn on the Reference channel the load file window will appear 3 3 Setup Horizontal System Change Time Div The Time Div Selects the horizontal Time DIV scale factor for the main or the window time base The Horizontal Panel ...

Page 43: ... Y Y T Show the relative relation between vertical voltage and horizontal time X Y Show CH1 value at X axis CH2 value at Y axis Change Horizontal Position Double click the channel button to set the trigger point to the horizontal center of the screen Horizontal position changes the displayed waveform position relative to the trigger point The user can drag on screen to change the horizontal positi...

Page 44: ...e oscilloscope continues to acquire enough data so that it can draw the waveform to the right of the trigger point after it detects a trigger The Edge trigger determines whether the oscilloscope finds the trigger point on the rising or the falling edge of a signal Select Edge trigger mode to trigger on Rising edge or Falling edge Mode Select the trigger mode Sweep Set the sweep mode to Auto Normal...

Page 45: ...ling Rising Trigger on rising edge Falling Trigger on falling edge The user can also change the trigger setting on trigger panel in sidebar Set Pulse Trigger Pulse trigger occurs according to the width of pulse The abnormal signals can be detected through setting up the pulse width condition Mode Sweep Source PW Condition Pulse Width The Pulse Width adjust range is 10ns 10s When the condition is m...

Page 46: ...r modes for the four vertical channels Options Settings Comments Pulse With Pulse highlighted the trigger occurs on pulses that meet the trigger condition defined by the Source When and Set Pulse Width options Sweep Auto Normal Single Auto Acquire waveform even no trigger occurred Normal Acquire waveform when trigger occurred Single Acquire waveform when trigger occurred then stop Source CH1 CH2 C...

Page 47: ...ing pulse condition Pulse Width Set Pulse Width highlighted including Time Unit and Pulse Width Video Trigger Mode Select the trigger mode Sweep Source Set the Trigger Channel to CH1 CH2 CH3 CH4 Trigger Sync Trigger Standard Options Settings Comments Video With Video highlighted an NTSC PAL or SECAM standard video signal will be triggered The trigger coupling is preset to AC Sweep Auto Normal Sing...

Page 48: ... Select the trigger mode Trigger Channel Set the Trigger Channel to CH1 CH2 CH3 CH4 Trigger Type Set the Trigger Type to Edge or Pulse PW Condition Set the PW Condition to the following condition More Pulse width more than selecting pulse condition Less Pulse width less than selecting pulse condition Equal Pulse width equal to selecting pulse condition More Pulse width more than selecting pulse co...

Page 49: ...well OS100 Digital Oscilloscope User s Guide_English Version_V1 00 The user can also change the trigger setting on trigger panel in sidebar High Frequency Rejection Select HF Rejection in Trigger Setup window ...

Page 50: ...0 Digital Oscilloscope User s Guide_English Version_V1 00 The user can turn on HF Rejection to eliminate trigger higher frequency 20M above 3 5 Save Load Save Click File in main menu to save waveform setups and screen ...

Page 51: ...ad Setup Load the instrument that had saved 3 6 Utility Function 3 6 1 Record The following picture shows the Record Interface The dialog box of record is shown on the lower right corner of the screen This function can record input waveform form CH1 CH2 CH3 CH4 Storage Record waveform and save it as dfr file Play Back button Click this button to start playing back waveform Start button Start to re...

Page 52: ...d file The Max length of this file is about 1GB When recording data length is more than 1GB it will create next file named data 1 drf and so on When click play back button it will play back data from the first file data 0 drf to the last file If you want to read an arbitrary file please delete the data drf and then play back 3 6 2 Pass Fail Click Pass Fail in Utility menu ...

Page 53: ...e Pass Fail function monitors changes of signals and outputs pass or fail signals by comparing the input signal with the pre created mask Control Setting Source Select the Pass Fail channel Output Select the Pass Fail output condition Stop When Output If it was checked the Pass Fail will stop when output ...

Page 54: ...imit range Create button Click this button to create Pass Fail area according to the mask Save button Click this button to save the setups to file Load button Click this button to load the saved setups file Information Display Fail It shows the fail waveform number Pass It shows the pass waveform number Total It shows the l total Pass Fail waveform number ...

Page 55: ...V1 00 Operation Click Start button to start the Pass Fail test Click Stop button to stop the Pass Fail test The Pass Fail function display NOTE Pass Fall function is unavailable in X Y mode 3 6 3 Factory Setup Click Factory Setup in Utility menu to load default setups ...

Page 56: ...orms and removes all other waveforms The oscilloscope set up for normal operation when it is shipped from the factory and can be recalled at anytime by user The Factory Setup function does not reset the following settings Language option Date and time 3 6 4 Language Click Language in Utility menu There are four languages in Language menu The default language is English ...

Page 57: ...cursors 1 Source The user can set the source to CH1 CH2 CH3 CH4 and MATH When you use cursors be sure to set the Source to the waveform on the display that you want to measure 2 Type There are four types of cursors Cross Trace Vertical and Horizontal 1 Cross The Cross cursors appear as cross lines on the display and measure the vertical and horizontal parameters The Cross cursor display window ...

Page 58: ...de_English Version_V1 00 The Cross measure result displays on status bar 2 Trace The Trace cursors appear as vertical lines on the display and measure the waveform amplitude at the point the waveform crosses the cursor The Trace cursor display window ...

Page 59: ...ope User s Guide_English Version_V1 00 The Trace cursor measure result display on status bar 3 Vertical The Vertical cursors appear as vertical lines on the display and measure the vertical parameters The Vertical cursor display window ...

Page 60: ...er s Guide_English Version_V1 00 The Vertical cursor measure result display on status bar 4 Horizontal The Horizontal cursors appear as horizontal lines on the display and measure the horizontal parameters The Horizontal cursor display window ...

Page 61: ...ser s Guide_English Version_V1 00 The Horizontal cursor measure result display on status bar 3 7 2 Measure Menu Click Measure in main menu The oscilloscope provides 20 parametric auto measurements 12 voltage and 8 time measurements 1 Source ...

Page 62: ... absolute minimum level Measured over the entire waveform Peak To Peak Peak to peak Max Min Measured over the entire waveform Top Voltage of the statistical maximum level Measured over the entire waveform Base Voltage of the statistical minimum level Measured over the entire waveform Middle Voltage of the 50 level from base to top RMS The Root Mean Square voltage over the entire waveform Amplitude...

Page 63: ...eriod of the first cycle to complete in the waveform Rise Time Time taken from lower threshold to upper threshold Fall Time Time taken from upper threshold to lower threshold Duty Cycle Positive Duty Cycle Positive Pulse Width Period x 100 Measured of the first cycle in waveform Duty Cycle Negative Duty Cycle Negative Pulse Width Period x 100 Measured of the first waveform Pulse Width Measured of ...

Page 64: ...ults of the automatic measurements will be displayed on the bottom of the screen Maximum 8 results could be displayed at the same time When there is no room the next new measurement result will make the previous results moving left out of screen 5 Edit Measure Click Measure Edit Measure ...

Page 65: ...1 00 User can select Maximum 8 measure options to measure 3 8 The Display System 3 8 1 Display Type Click Type in Display menu The following figure shows the type parameters setting If the Vectors type mode is selected the waveform will be displayed as following figure ...

Page 66: ...66 Foxwell OS100 Digital Oscilloscope User s Guide_English Version_V1 00 If the Dots type mode is selected the waveform will be displayed as following figure ...

Page 67: ...67 Foxwell OS100 Digital Oscilloscope User s Guide_English Version_V1 00 3 8 2 Display Grid Click Display in main menu The grid shows The grid not shows ...

Page 68: ...er s Guide_English Version_V1 00 3 8 3 Intensity Click Display Intensity in main menu The following figure shows the intensity dialog It shows the display parameters setting You can change the grid and waveform color intensity in this dialog ...

Page 69: ... button The user can change the waveform display by adjusting the scale and position When you change the scale the waveform display will increase or decrease in size When you change the position the waveform will move up down right or left The channel reference indicator identifies each waveform on the display The indicator points to the reference level of the waveform record ...

Page 70: ...click the mouse button on display screen to zoom in out the waveform Also the user can change Time Div in Horizontal menu or in Horizontal panel to zoom in out the waveform Drag The user can modify the waveform position after clicked Drag in Acquire menu following the following steps 1 Select Channel 2 Set the Move Step 3 Change the waveform position ...

Page 71: ...oscope User s Guide_English Version_V1 00 3 10 Interpolation At the time base 40ns div or faster user can use the 3 different interpolation mode to get waveforms of different smoothness The Step Interpolation The Linear Interpolation ...

Page 72: ...72 Foxwell OS100 Digital Oscilloscope User s Guide_English Version_V1 00 The Sin x x Interpolation ...

Page 73: ...ail in the acquisition 3 11 Acquisition Modes There are two acquisition modes Normal Average and Peak Detect Normal In this acquisition mode the oscilloscope samples the signal in evenly spaced intervals to construct the waveform Average In this acquisition mode the oscilloscope acquires several waveforms averages them and displays the resulting waveform You can use this mode to reduce random nois...

Page 74: ...et the printer to print the current waveform 2 Click the PrintPreview in File menu to get into the Preview window In PrintPreview window use the Zoom In button and the Zoom Out button to change the size of the waveform graph Click the Close button to turn this window off and click the Print button to print the report The Print report ...

Page 75: ...75 Foxwell OS100 Digital Oscilloscope User s Guide_English Version_V1 00 ...

Page 76: ... Setup on menu The DSO set the vertical horizontal and triggers controls at the best status automatically Also you can adjust the controls to meet your measurement to optimize the waveform display To measure the frequency and Vpp you can do these steps as follows 1 Click the Measure Horizontal Frequency button the frequency of the signal display on the bottom of the waveform interface 2 Click the ...

Page 77: ...er Slope to which means you select the rising edge 5 Adjust the Volts Div and the time base in a proper range for the signal 6 Drag the trigger level sign on the waveform display screen to proper position It ally higher a little above the normal level 7 Click START button to start capturing When the trigger conditions are met data appears on the display representing the data points that the oscill...

Page 78: ... the input of the circuit and connect the CH2 probe to the output of the circuit 3 Click button 4 Adjust the vertical scale and offset to display approximately the same amplitude signals on each channel 5 Select X Y format at Horizontal window The oscilloscope will displays a Lissajous pattern representing the input and the output characteristics of the circuit 6 Adjust the scale and offset of the...

Page 79: ... range of π 2 π or π 3π 2 4 5 Taking Cursor Measurements Use cursors to make time and amplitude measurements on a waveform quickly Measure the Peak Frequency or Time of the First Sine Waveform Do these steps 1 Click Cursor Source select CH1 select CH2 if you want measure CH2 2 Click Cursor Type select Vertical 3 Push left mouse button and the vertical lines appear 4 Drag the mouse button to the po...

Page 80: ...eak of the Waveform Do these steps 1 Click Cursor Source select CH1 select CH2 if you want measure CH2 2 Click Cursor Type select Horizontal 3 Push left mouse button and the Horizontal lines appear 4 Drag the mouse button to the point you want to measure 5 Release the left mouse button the voltage difference will be shown at the status bar Measure the Amplitude ...

Page 81: ...the status bar Trace the Amplitude of a fixed position on X axis in a Waveform Do these steps 1 Click Cursor Source select CH1 select CH2 if you want trace CH2 2 Click Cursor Type select Trace 3 Click the cursor at the position that you want traced of the wave in the waveform window Trace the Amplitude ...

Page 82: ...82 Foxwell OS100 Digital Oscilloscope User s Guide_English Version_V1 00 Read the details showing in the status bar Note Click Cursor Type select Cross you can measure time and amplitude at one time ...

Page 83: ...form To output a Sine Wave please do the following steps 1 Press the check box On Off to open the wave output function 2 Select the Wave Type Sine Wave 3 Set the Wave Parameter Frequency Set the output wave frequency Sweep Set the output wave to sweep Amplitude Set the output wave amplitude Y Offset Set the output wave vertical level offset Phase Set the output wave phase The Sine waveform window ...

Page 84: ... 1 Press the check box On Off to open the wave output function 2 Select the Wave Type Square 3 Set the Wave Parameters Frequency Set the output wave frequency Amplitude Set the output wave amplitude Y Offset Set the output wave vertical level offset Phase Set the output wave phase Duty Set the duty of the output wave The Square waveform window as the following ...

Page 85: ...orm To output an AM FM Wave please do the following Steps 1 Press the check box On Off to open the wave output function 2 Select the Wave Type AM FM 3 Set the Wave Parameters Frequency Set the output wave frequency Amplitude Set the output wave amplitude Y Offset Set the output wave vertical level offset ...

Page 86: ...ish Version_V1 00 Phase Set the output wave phase High Frequency Set the output wave Hight Frequency Depth Set the output wave Depth Max Frequency Set the output wave Max Frequency FM Change the output wave AM into FM The AM FM waveform window as following ...

Page 87: ...ps 1 Press the check box On Off to open the wave output function 2 Select the Wave Type Ramp 3 Set the Wave Parameters Frequency Set the output wave frequency Amplitude Set the output wave amplitude Y Offset Set the output wave vertical level offset Phase Set the output wave phase Duty The duty of the output wave The Ramp waveform window as the following ...

Page 88: ... box On Off to open the wave output function 2 Select the Wave Type Trapezia Frequency Set the output wave frequency Amplitude Set the output wave amplitude Y Offset Set output wave vertical level offset Phase Set the output wave phase Duty Set the output wave duty Rise Duty Set the output wave rise duty High Duty Set the output wave high duty Fall Duty Set the output wave fall duty ...

Page 89: ...ersion_V1 00 The Trapezia waveform window as the following 4 6 6 Generate the Gause waveform To output a Gause Wave please do the following steps 1 Press the check box On Off to open the wave output function 2 Select the Wave Type Gause 3 Set the Wave Paramters ...

Page 90: ...indow as the following 4 6 7 Generate the Arb waveform To output an Arbitrary Waveform please do the following steps 1 Press the check box On Off to open the wave output function 2 Select the Wave Type Arb 3 Set the Wave Parameters Frequency Set the output wave frequency 4 Set the output wave The Arb waveform window as the following ...

Page 91: ...e check box On Off to open the wave output function 2 Select the Wave Type Exponent 3 Set the Wave Parameters Frequency Set the output wave frequency Amplitude Set the output wave amplitude Y Offset Set the output wave vertical level offset Phase Set the output wave phase Tao Set the ouput wave Tao param Rise Set the output wave slope The Exponent waveform window as the following ...

Page 92: ...on_V1 00 4 6 9 Generate the White noise waveform To Generate a White noise Wave please do the following steps 1 Press the check box On Off to open the wave output function 2 Select the Wave Type White 3 Set the Wave Parameters Amplitude Set the output wave amplitude ...

Page 93: ...93 Foxwell OS100 Digital Oscilloscope User s Guide_English Version_V1 00 The White noise waveform window as the following Chapter 5 Appendix Appendix A Specifications Appendix B General Maintenance ...

Page 94: ...um Input Protection 400V DC AC Peak Horizontal Real Time Sampling Rate 1GS s Time Base Range 2ns div to 1000s div 1 2 5 sequences Time Base Precision 50ppm Trigger Source CH1 CH2 CH3 CH4 Mode Edge Pulse Video Alternative X Y mode X Axis Input CH1 Y Axis Input CH2 Phrase Shift Max 3 degree Cursors and Measurement Voltage Measurement Vpp Vamp Vmax Vmin Vtop Vmid Vbase Vavg Vrms Vcrms Preshoot Oversh...

Page 95: ...ht 1Kg Appendix B General Maintenance General Care Do not store or leave the oscilloscope where the device will be exposed to direct sunlight for long periods of time Caution To avoid damages to the device or probes do not expose them to sprays liquids or solvents To avoid damages to the surface of the device or probes not use any abrasive or chemical cleaning agents Cleaning Inspect the device an...