background image

DPT701 Digital Pressure Tester User’s Guide_English Version_V2.00

9

2.2 Accessory Descriptions

This section lists the accessories that go with the tester. If you find any of the following items

missing from your package, contact your local dealer for assistance.
1 User’s Guide
2 80 Bar Sensor
3 Wireless PC receiver
4 Spare Fuse
5 2X2 Diagnostic Adapter
6 CD
7 Sealant
8 Blower Molding Case

9

Bluetooth Adapter

2.3 Technical Specifications

Sensor type

: Strain gauge technology, amplified and digital temperature compression

Sensor output

: Ratiometric, 0.5/4.5 V DC at 5 V DC excitation

Sensor FS

.: 80 bar / 1160 psi

Resolution

: 0.1 bar / 1psi

Proof pressure

: 150% FS

Battery type

: 9V

Display

: Backlit 64x128 pixels graphic LCD

Data transmission interface

: wireless module

Adapters included

: 6mm and 8mm

Working Temperature

0 to 60

(32 to 140

)

Storage Temperature

-20 to 70

(-4 to 158

)

Dimensions

190*110*44mm

3 Getting Started

This section describes how to provide power to the tester and how to program the scanner to

meet your specific needs

3.1 Providing Power to Tester

Before using the tester, make sure to provide power to the tester.

The unit operates on 9-volt cell battery

3.1.1 Powered by Cell Battery

The scan tool receives power through a 9 volt cell battery which installed in the back of the tester.
To install the battery

1. Prepare a 9 volt lithium battery.

2. Install this battery in the back of the tester. Please pay attention to its positive pole and negative

pole.

3. Press the power switch of the tester to power it on.

3.1.2 Replace Battery(9V)

1.If the product does not go on or goes out repeatedly, the power supply battery might be too low.

2.To replace the battery, open the rear cover of the instrument to gain access to the battery

compartment. Replace the battery with a new 9-volt battery and replace the cover on the back of

the instrument.

Summary of Contents for DPT701

Page 1: ...e holders Copyright Information 2013 Shenzhen Foxwell Technology Co Ltd All rights reserved Disclaimer The information specifications and illustrations in this manual are based on the latest information available at the time of printing Foxwell reserves the right to make changes at any time without notice Visit our website at www foxwelltech com For Technical Assistance send us email at support fo...

Page 2: ... after the completion of service under this limited warranty 4 FOXWELL does not warrant uninterrupted or error free operation of the product If a problem develops during the limited warranty period the consumer shall take the following step by step procedure a The customer shall return the product to the place of purchase for repair or replacement processing contact your local FOXWELL distributor ...

Page 3: ...ANY OTHER LEGAL OR EQUITABLE THEORY EVEN IF FOXWELL KNEW OF THE LIKELIHOOD OF SUCH DAMAGES FOXWELL SHALL NOT BE LIABLE FOR DELAY IN RENDERING SERVICE UNDER THE LIMITED WARRANTY OR LOSS OF USE DURING THE PERIOD THAT THE PRODUCT IS BEING REPAIRED 6 Some states do not allow limitation of how long an implied warranty lasts so the one year warranty limitation may not apply to you the Consumer Some stat...

Page 4: ...low all safety messages Do not route the test cable in a manner that would interfere with driving controls Do not exceed voltage limits between inputs specified in this user s manual Always wear ANSI approved goggles to protect your eyes from propelled objects as well as hot or caustic liquids Fuel oil vapors hot steam hot toxic exhaust gases acid refrigerant and other debris produced by a malfunc...

Page 5: ...STER DESCRIPTIONS 8 2 2 ACCESSORY DESCRIPTIONS 9 2 3 TECHNICAL SPECIFICATIONS 9 3 GETTING STARTED 9 3 1 PROVIDING POWER TO TESTER 9 3 1 1 Powered by Cell Battery 9 3 1 2 Replace Battery 9V 9 3 2 SYSTEM SETUP 10 3 2 1 Select Language 10 3 2 2 Select Measurement Unit 10 3 2 3 Save The Plate Number 10 3 2 4 Backlight 10 4 DIAGNOSTIC OPERATION 11 4 1 START UP AUTO TEST 11 4 2 DIAGNOSTIC FUNCTION SELEC...

Page 6: ...igital Pressure Tester User s Guide_English Version_V2 00 6 4 2 6 Common Rail Test Low Pressure Circuit 16 4 2 6 1 About The Common Rail System 16 4 2 6 2 To perform low pressure circuit test 16 5 PRINT DATA 18 ...

Page 7: ...u that lists all available options displays Menu options include Languages Unit Workshop Name saving 1 2 2Arrow Icon An arrow icon indicates a procedure Example To change menu language 1 Scroll with the arrow keys to highlight Language on the menu 2 Press the ENTER key to select 1 2 3 Note and Important Message Note A NOTE provides helpful information such as additional explanations tips and comme...

Page 8: ... 2 Back Key cancels an action and returns to previous screen or level 3 Printing Key it s used to send the test result to the printer if needed With the wireless printing module the user can print the test data without the action to connect it to a printer 4 OK Key confirms an action or movement and goes to next level and saves test data 5 Wireless Receiver Key is used to send data to a PC using t...

Page 9: ...to 140 Storage Temperature 20 to 70 4 to 158 Dimensions 190 110 44mm 3 Getting Started This section describes how to provide power to the tester and how to program the scanner to meet your specific needs 3 1 Providing Power to Tester Before using the tester make sure to provide power to the tester The unit operates on 9 volt cell battery 3 1 1 Powered by Cell Battery The scan tool receives power t...

Page 10: ...system language 1 Scroll with the up and down arrow keys to highlight Language from Setup menu and press the OK key to confirm Figure 3 1 Sample Language Selection Screen 3 2 2 Select Measurement Unit After confirming the language the tester will automatically show the selection of measurement unit The tester is set to display BAR as default pressure standard To select measurement unit 1 Scroll wi...

Page 11: ...art up Auto Test A start up auto test assures the user that the battery the sensor and the microprocessor are working properly when the tester is turned on To perform Start up Auto Test 1 Connect the pressure sensor to the pressure tester then press power on key to turn on the tester The display will show the welcome message for three seconds Figure 4 1 Sample Start up Welcome Screen 2 A power on ...

Page 12: ...ce options displays Menu options typically include Oil pressure test Petrol compression Diesel compression 80 Bar manometer Petrol inj system Low side common rail 4 2 1 Oil Pressure Test The oil pressure test allows you to test oil pressure By default the maximum reading will be shown on the display To perform oil pressure test 1 Scroll up and down arrow keys to select Oil pressure test from the o...

Page 13: ...ine compression To perform Petrol compression test 1 Scroll up and down arrow keys to select Petrol compression from the option menu and press OK key to confirm Figure 4 10 Sample Select An Option Menu Screen 2 The petrol compression will be displayed Scroll up and down arrow keys to select the right cylinder and the maximum reading will be displayed and stored automatically Figure 4 11 Sample Pet...

Page 14: ...der and the maximum reading will be displayed and stored automatically Figure 4 14 Sample Diesel Compression Screen 3 Use the left arrow key to clear the reading of the selected cylinder and pressing the right arrow key you can toggle between graphical and text display Figure 4 15 Sample Graphical Display Screen NOTE The graphic bar will represent 0 to 80 bar when testing diesel compression 4 2 4 ...

Page 15: ...pressing the right arrow key 4 2 5 Petrol Injection System Petrol Injec System allows you to test petrol pressure The actual reading will be shown on the screen by default To perform Petrol Injection System 1 Scroll up and down arrow keys to select Petrol Injec System from the option menu and press OK key to confirm Figure 4 19 Sample Select An Option Menu Screen 2 The actual reading will be displ...

Page 16: ...act that the nozzles are controlled electronically so an electronic unit decides what the exact amount of fuel needed by the engine is and sends an electrical signal to the injectors to open the nozzle At that time the fuel pressure in the common rail passes through the nozzles and goes into the cylinders The name common rail comes from the fact that the injectors are all connected to a common rai...

Page 17: ...ure 4 24 Sample Select An Option Menu Screen Step 1 Pressure at high pressure pump input After pressing the OK key the following test screen displays Press OK key to continue the test or press BACK key to return to previous menu Figure 4 25 Sample Low Pressure Circuit Test Step 1 Screen NOTE The normal pressure value of test 1 is 2 5 Bar Press OK key to go to next step if it shows 2 5 Bar or extre...

Page 18: ...ill 2 5 bar or higher it indicates faulty regulator if the pressure is too low it indicates faulty low pressure pump Step 3 Pressure of the return circuit After step 2 please press the OK key and the following test screen displays Press OK key to continue the test or press BACK key to return to previous menu Figure 4 27 Sample Low Pressure Circuit Test Step 3 Screen NOTE The normal pressure value ...

Page 19: ... www foxwelltech com product item 19 html then run setup exe file Figure 5 1 Sample setup exe software 2 Connect USB Bluetooth Adapter with the computer if your computer don t equipped with Bluetooth function then it will install the diver automatically Or turn on the computer bluetooth on PC and Devices if your computer has Figure 5 2 Sample bluetooth on PC 3 Double press to enter the Oil Pressur...

Page 20: ...computer and then the Dynamic Pressure screen popped up with a graph showing the data after waiting about 30s Figure 5 4 Sample Dynamic Pressure Graph Screen 6 Press Print key to print the data You are required to create the Plate Number on the tester Figure 5 5 Sample Plate Number Input Screen 7 The following print screen will pop up ...

Page 21: ...DPT701 Digital Pressure Tester User s Guide_English Version_V2 00 21 Figure 5 6 Sample Data Print Screen 8 Click print report to print the data through computer Figure 5 7 Sample Data Report Screen ...

Reviews: