FoxGate S6016G POE User Manual Download Page 8

 

9

10

 

2.4 Cable Connection

2 4 1 

. . Device Connection

U s e  c r o s s  n e t w o r k  c a b l e  o r  c r o s s - o v e r  c a b l e  t o  c o n n e c t  P C  o r 

other device with switch

'

s Ethernet port;

2 4  Configuration Cable 

. .2

Connection

Use

 

a

 

network

 

cable

 

to

 

connect

 

all

 

Ethernet

 

ports

 

 

(

with

 

management

 

PC,  and  use  management  PC  to 

configure the PoE switch.

Notice

The

 

VLAN

 

ID

 

of

 

this

 

Ethernet

 

port

 

must  be  1) 

Figure 2-5 Connect configuration cable

2

.4. Power 

cable

 Connection

 

 

Figure 2

-

6 Connect

 

power cable

(

1 Connect one side of switch’s power cable with the switch

'

s AC power port, 

and connect the another side with external AC power socket;

heck

 

if switch

'

s AC

 

power LED

 

is

 

on

that  means

 

power

 

connected correctly

;

)

(

2

)

Turn on the power

 ,

c

(

3

)

Use

 

the

 

power plug snap

 

to

 

jammed the AC Power cable.

 

3.2.1 Set Static IP for the Management Computer

Operation

 

steps (take Windows

 

XP

 

as

 

sample

)

3.

 

 

Computer Requirements

Make

 

sure

 

the

 

management

 

PC has

 

already been

 

installed with Ethernet

 

adapter;

3 2 

. Set Up Network Connection

 

 

(1) You

 

need

 

to

 

set

 

the

 

IP

 

of

 

the

 

PC

 

and

 

the

 

switch

 

in

 

the

 

same

 

network

 

segment. The default IP address of the switch  is 192.168.1.200, 

network gate is 255.255.255.0.

(2) The

 

port to connect management PC for

 

Web

 

setting must be 

management VLAN. By default, management VLAN is VLAN 1,and each 

port of the switch is VLAN1.

(3) If you need to connect the remote network, please make sure the 

management PC and the router can do the job above.

(4) This product can

'

t assign the IP address for the management PC, you 

need to set the management static IP by 

yourself

.

3 Function Configuration Guide

(1) Click <start> to enter the [start] 

menu, select “control panel”. Double 

click “network connection”  icon,  

double click the “local connection” 

icon, pop out “local connection  

status” window. 

Use

 

network

 

cable

 

connect

 

Ethernet ports with network card of PC

.

Instruction

Summary of Contents for S6016G POE

Page 1: ...User Manual 16 24 Ports Managed PoE Ethernet Switch 16 24FE POE 2GE...

Page 2: ...evice or cause data loss Supplemental instruction for operation contents Format Description Illustration 1 Format of Graphics Interface means button name such as click Confirm button means window name...

Page 3: ...ion 15 3 3 5 Web Users Timeout 17 3 3 6 Backup System Configuration Information 17 3 3 7 Restoring the Configuration Information 17 2 4 Cable Connection 2 1 4 Device Connection 2 2 4 Configuration Cab...

Page 4: ...ation process Support high speed data forwarding perfectly designed for large flow of video data forwarding in security surveillance Support one key recovery of IP address user password Quick fixing e...

Page 5: ...truction 1 4 Specification Item Description Products Products 24 Ports PoE Ethernet Switch 16 Ports PoE Ethernet Switch Power Power Supply Mains on load Voltage Range AC 100 240V Consumption 420W 300W...

Page 6: ...n it is working the switch may be affected by external interference outside the system through the ways of radiation and conduction Please pay attention to the followings AC power supply is TN system...

Page 7: ...can put this product on clean stable grounded workbench The installation procedure as below 1 Carefully put the device upside down clean the grooves on the chassis backplane with soft cloth to make s...

Page 8: ...ion steps take Windows XP as sample 3 1 Computer Requirements Make sure the management PC has already been installed with Ethernet adapter 3 2 Set Up Network Connection 1 You need to set the IP of the...

Page 9: ...255 0 Click OK to finish the configuration 3 2 2 Confirm the Network Connection by Ping Command Operation Steps below 2 Input ping 192 168 1 200 click confirm button If there is equipment response sho...

Page 10: ...s the Enter key the user login page will show in front of you as follows http 192 168 1 200 The browser version recommend IE7 and later Firefox browser Chrome 360 browser IE7 and later Please follow t...

Page 11: ...d Rate Auto negotiation Port duplex mode Auto negotiation Flow Control Open Trunking Port does not converge Port Speed Limitation No limitation for Speed Port Link Type Access VLAN Management VLAN VLA...

Page 12: ...escription Word Time Zone Display different time zones around the world For example select Automatically Adjust Daylight Saving Time in daylight saving time zone Time Configuration You can select loca...

Page 13: ...oid packet loss and ensure normal operation of network services By default the flow control function of the port is enabled 24 Ports Managed Ethernet Switch PoE Ethernet Switch Web Port 1 2 3 4 5 6 7...

Page 14: ...pe is Broadcast packet 4 3 VLAN Setting Switch supports two VLAN modes 1 Port based VLAN mode define VLAN members according to device port After you specify the port to a VLAN specified VLAN Packets c...

Page 15: ...e VLAN ID and default VLAN ID is different and is allowed to pass through the port maintain the original tag and send the message 4 2 3 VLAN Forwarding Enter 1 10 within the port range or click on the...

Page 16: ...k avoiding declined processing capacity and receiving same messages repeatly Caution Configuration Guide Such as connect the switch A s 1 2 ports with switch B s 1 2 ports Enable a convergence group i...

Page 17: ...ation on the switch shown in figure 4 6 Figure 4 6 RSTP Instruction The meaning of main parameters of the pages as below Table 4 8 Parameters description 4 4 2 3 RSTP Introduction Parameters Descripti...

Page 18: ...y Path cost enter 0 is automatically detected Port priority choose 128 Point to point choose yes Edge port choose No Click save operation switch A B C RSTP function finished Enable static address latc...

Page 19: ...de selection compulsory licensing maximum number of users input 10 Click setting and save Operation finished Instruction 1 Between the applicant and the authentication system using MD5 inquiry do not...

Page 20: ...rs Caution The meanings of main parameters of the pages are as below table Table 4 12 Parameters description On the Network management Email alarm page you can turn on off Email alarm service shown in...

Page 21: ...n Guidance Such as port 3 monitor port 2 Import data traffic 1 This feature must be turned off in normal use otherwise all based on advanced management capabilities port can use such as RSTP IGMP SNOO...

Page 22: ...C table page you could check MAC address of each port as the figure 4 14 shows Parameters Description Receive Package Frame singlecast The r the unicast address eceived address is the number of packet...

Page 23: ...just shown in figure 4 15 Network Id and Host Id Parameter Description Inquiry by physical port Enter detailed physical MAC address to check Inquiry by MAC address type MAC address type consists of st...

Page 24: ...at cfg Software Update Select the software you want to upgrade Restore Factory Defaults Recover all configuration except for IP address user name and password System Reboot Restart system and return t...

Page 25: ...Please note that when insert a new PD equipment the power will be distributed based on the detected PD power level instead of the actual power of inserted PD for example when surplus power is 20W the...

Page 26: ...lowest priority queue Priority 2 and 3 mapped to the second priority queue 4 and 5 priority priority mapping to the third queue 6 and 7 mapped to the highest priority priority queue is the highest pr...

Page 27: ...This product design is environmental friendly and the product should be stored used and dicarded in accordance with relevant national legal regulatory requirements Environment protection 47...

Reviews: