RAID CONFIGURATION
90
Intel(R) Matrix Storage Manager option ROM v5.0.0.1011 ICH9R wRAID5
Copyright(C) 2003-04 Intel Corporation All Rights Reserved.
1. Create RAID Volume
4. Recover Volume Options
2. Delete RAID Volume
5. Acceleration Options
3. Reset Disks to Non-RAID
6. Exit
RAID Volume :
ID
Name
Level Stripe
Size Status Bootable
0
TryRAID5
RAID5(Parity) 64KB 149.1GB
Normal
Yes
Physical Disks:
Port Drive Model
Serial #
Size Type/Status(Vol ID)
0
Hitachi HDS72161
PVF904Z21G2JZM
149.0GB
Member Disk(0)
1
ST380811AS
5PS1TAGW
74.5GB
Member Disk(0)
2
SAMSUNG HD161HJ
S0V3J9APA30524
149.0GB
Non-RAID Disk
3
ST380815AS
5RW1CA37
74.5GB
Non-RAID Disk
Intel(R) Rapid Storage Technology - Uption ROM - 11.0.8.1204
Copyright(C) 2003-11 Intel Corporation. All Rights Reserved.
[
DISK/VOLUME INFORMATION
]
[
MAIN MENU
]
[↑↓]-Select [ESC]-Exit [ENTER]-Select Menu
"Degraded" volume and disk available for rebuilding detected. Selecting
a disk initiates a rebuild. rebuild completes in the operating system.
Select the port of the destination disk for rebuilding (ESC to exit):
Port Drive Model
Serial #
Size
2 SAMSUNG HD161HJ
S0V3J9APA30524
140.9GB
3 ST380815AS
5RW1CA37
74.5GB
[
DEGRADED VOLUME DETECTED
]
3 ST380815AS
5RW1CA37
74.5GB
[↑↓]-Previous/Next [ENTER]-Select [ESC]-Exit
5. It goes back to Main menu with a "Rebuild" status of RAID5 volume. Eventually, a replace-
ment hard disk has to join in and it always keeps three hard disks in the RAID5 system.
6. Operating System will perform the rebuilding later.
Intel(R) Matrix Storage Manager option ROM v5.0.0.1011 ICH9R wRAID5
Copyright(C) 2003-04 Intel Corporation All Rights Reserved.
1. Create RAID Volume
4. Recovery Volume Option
2. Delete RAID Volume
5. Acceleration Options
6. Exit
RAID Volume :
ID
Name
Level Stripe
Size Status Bootable
0
TryRAID5
RAID5(Parity) 64KB 149.1GB
Rebuild
Yes
Physical Disks:
Port Drive Model
Serial #
Size Type/Status(Vol ID)
0
Hitachi HDS72161
PVF904Z21G2JZM
149.0GB
Member Disk(0)
1
ST380811AS
5PS1TAGW
74.5GB
Member Disk(0)
2
SAMSUNG HD161HJ
S0V3J9APA30524
149.0GB
Non-RAID Disk
3
ST380815AS
5RW1CA37
74.5GB
Member Disk(0)
Volume with “Rebulid” status will be rebuilt within the operating system.
Intel(R) Rapid Storage Technology - Uption ROM - 11.0.8.1204
Copyright(C) 2003-11 Intel Corporation. All Rights Reserved.
[
DISK/VOLUME INFORMATION
]
[
MAIN MENU
]
3. Reset Disks to Non-RAID
[↑↓]-Select [ESC]-Exit [ENTER]-Select Menu