Fourgroup DUPLEX-UP Use And Installation Manual Download Page 14

 

14

 
 
 
 

Our products are guaranteed for a year from the date of commissioning; this applies 
only to products purchased from our offices or from our authorized retailers. The 
warranty does not extend beyond 15 months from the date of shipping. If the 
shipping documentation is missing, the date of manufacture is given in the code on 
the nameplate or fused into the interior of the terminal box. The warranty covers all 

manufacturing defects of material manufactured by us; it covers replacement and 
repair only, at our premises and by our staff, of the defective panel or part. The 
warranty does not provide for any claims by the customer. The warranty does not 
cover damage caused by faulty electrical connections, lack of adequate protection, 
incorrect assembly, incorrect use or any negligence in installing and operating the 
plant. 

The WARRANTY is also void in the following circumstances: 
- damage due to corrosion or abrasion of any type or nature; 
- malfunction due to improper installation; 
- repair, disassembly or tampering by unauthorized persons; 
- failure by the customer to pay due amounts. 

The defective product must be returned to our factory carriage paid. We reserve the 
sole right to determine the cause of the defect and whether it is covered by the 
warranty or not. After the repair, the goods will be returned to the Customer carriage 
forward. 
WE DECLINE all liability for damages and injury caused by our products. 

Fourgroup S.r.l. reserves the right to modify its products without notifications. Any 
controversy arising from the terms of this warranty shall be resolved in the Padua 
Court, even if payment is agreed by bank’s draft. 
For any further information, refer to the sales contract. 
 

 
 
 
 
 
 

Always state the exact model identification number and construction number when 
requesting technical information or spare parts from our sales and service centre. 
 
 

Use only original spare parts when replacing any faulty components. 

 
 
 

The use of unsuitable spare parts can cause malfunctions, personal injury 

 

and damage to property. 

 

 
 
 
 
 
 

 
 
 

13. WARRANTY 

14. SPARE PARTS 

 

 

Summary of Contents for DUPLEX-UP

Page 1: ...TION HANDBOOK DUPLEX UP CONTROL PANEL FOR 2 ELECTRIC PUMPS WITH CURRENT CONTROL PR T FG006172 Date 10 02 14 Rev 01 Via Enrico Fermi 8 35020 Polverara PD Tel 049 9772407 Fax 049 9772289 www fourgroup i...

Page 2: ...6 6 Installation page 7 8 7 Electrical connection page 9 10 8 Regulation and calibration page 11 9 Stop of the pumps page 12 10 Lights and push buttons page 12 11 Maintenance page 13 12 Waste disposal...

Page 3: ...rt them CAUTION The control panel must be connected by a qualified electrician in compliance with the electrical regulations in force CAUTION The electric pump or the motor and the panel must be conne...

Page 4: ...our customer service Our units must be installed in sheltered well ventilated non hazardous environments and must be used at a maximum temperature of 40 C and minimum of 5 C DANGER WARNING The panel m...

Page 5: ...2 pumps Possibility to exclude a damaged pump Internal selector for exclusion of pumps exchanger Push buttons for AUTO OFF MANUAL motor operation MANUAL temporary Green led for power on N 2 green led...

Page 6: ...function the second pump starts after 4 5 second G A input is used as LEVEL ALARM function when switches on the 12Vcc SIREN output is ON with a MAXIMUM absorption 30 mA The green pilot lights Motor O...

Page 7: ...switch measured in accordance with the regulations locally in force Line of motor power supply Connect the unit at ground before carrying out any other operation The voltage input corresponds to the...

Page 8: ...ANEL TO A WALL AS IN PICTURE N 1 WITH SCREWS AND SCREW ANCHOR USING THE HOLES ARRANGED IN THE BOX OR THE FIXING BRACKET IF PRESENT AFTER THE FIXING REMOVE EVERY PLASTIC OR METALLIC SURPLUS ex Pieces o...

Page 9: ...WITH JUMPER IN ON POSITION PUMPS EXCHANGE IS ACTIVES WITH JUMPER IN OFF POSITION PUMPS EXCHANGE IS NOT ACTIVES G1 IS ONLY THE FLOAT SWITCH FOR PUMP 1 G2 IS ONLY THE FLOAT SWICTH FOR PUMP 2 JP1 JUMPER...

Page 10: ...PUMP 1 G2 IS ONLY THE FLOAT SWICTH FOR PUMP 2 JP1 JUMPER AUTORIT WITH JUMPER CONNECTED AUTORITENUTA IS ACTIVE G MIN IS USED AS STOP LEVEL FLOAT WITH JUMPER DISCONNECTED AUTORITENUTA IS NOT ACTIVE G MI...

Page 11: ...e current protection cut in delay time by CONNECTING the E T TA JUMPER Set the maximum value with the internal regulator on the Protection tripping current panel turn clockwise Turn the motor on and w...

Page 12: ...S ON RED LIGHT INDICATES THAT THE MOTOR IS RUNNING GREEN LIGHT CONTEMPORARY LIGHTING INDICATES THAT THE OVERLOAD PROTECTION IS ON RED LIGHTS INDICATES THAT THE CLICSON THERMAL PROTECTIONS IS ON RED LI...

Page 13: ...trol panel has been installed and started the customer must provide for the appropriate elimination disposal of the waste materials according to the legislation locally in force If the control panel o...

Page 14: ...f any type or nature malfunction due to improper installation repair disassembly or tampering by unauthorized persons failure by the customer to pay due amounts The defective product must be returned...

Page 15: ...wing European directives and with the national directives of actuation Machine 2006 42 CEE European Directive 2006 95 CE Electromagnetic compatibility 2004 108 CEE and the following technical rules EN...

Page 16: ...16 16 CONNECTION DIAGRAMS CONNECTIONS DUPLEX UP M CONNECTIONS DUPLEX UP T...

Reviews: