F8L10T LoRa Terminal User Manual 

 

Xiamen Four-Faith Communication Technology Co.,Ltd.

 

                         

Page 14 of 18 

     

Add

  11th Floor, A-06 Area, No.370, Chengyi Street, Jimei, Xiamen, Fujian, China.                                                                   

http://en.four-faith.com

                                Tel

  +86 592-5907276                          Fax

+86 592-5912735 

Power adapter and communication cable connection chart as following: 

 

2.4  Power 

The power range of the LoRa Terminal is DC 5~36V. 

Warning: When we use other power, we should make sure that the power can supply 

power above 4W. 

We recommend user to use the standard DC 12V/0.5A power. 

2.5  Indicator Lights Introduction 

The LoRa Terminal provides three indicator lights: “Power”, “ACT”, “Online”. 

Indicator Light 

State 

Introduction 

Power 

ON 

LoRa Terminal is powered on 

OFF 

LoRa Terminal is powered off 

ACT 

BLINK Data 

is 

communicating 

OFF No 

data 

Online 

ON 

LoRa Terminal has logged on network 

OFF 

LoRa Terminal hasn’t logged on network 

F8L10T 

 

F8L10T 

 

User Device 
(DB9M) 

User Device 

1

2

3

4

5

6

7

8

9

10

11

12

RX 

GND 

TX 

IO1 
IO2 
IO3 
IO4 

PWR 

GND 

IO5 

GND 

TX 

RX 

+

 

Anode 

-

 

Cathode 

RX 

1

2

3

4

5

6

7

9

10

11

12

RX 

GND 

TX 

IO1 
IO2 
IO3 
IO4 

PWR 

GND 

IO5 

+

 

Anode 

-

 

Cathode 

 

Connect via RS232 

Connect via RS485 

Summary of Contents for F8L10T

Page 1: ...ge V1 1 2 Product Name F8L10T Total 18 F8L10T LoRa Terminal User Manual Xiamen Four Faith Communication Technology Co Ltd Add 11th Floor A 06 Area No 370 Chengyi Street Jimei Xiamen Fujian China Tel 86 592 5907276 Fax 86 592 5912735 Web en four faith com ...

Page 2: ...sed Record Date Version Remark Author 2016 12 19 V1 0 0 Initial version WSP 2017 02 20 V1 1 0 According to the product line modify the radio frequency description Adjust the parameter configuration section with multiple details ZDD 2017 08 17 V1 1 1 Add Formulas to calculate collected value of ADC YSL 2017 11 09 V1 1 2 Add Fcc Warning Add Working Principle Modify Communication Frequency Band Modif...

Page 3: ...logy Co Ltd Without written permission all commercial use of the files from Four Faith are forbidden such as copy distribute reproduce the files etc but non commercial purpose downloaded or printed by individual all files shall be not revised and the copyright and other proprietorship notice shall be reserved are welcome Trademark Notice Four Faith 四信 are all registered trademarks of Xiamen Four F...

Page 4: ...rminal User Manual Xiamen Four Faith Communication Technology Co Ltd Page 4 of 18 Add 11th Floor A 06 Area No 370 Chengyi Street Jimei Xiamen Fujian China http en four faith com Tel 86 592 5907276 Fax 86 592 5912735 ...

Page 5: ...provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause ...

Page 6: ... 2 Features and Benefits 7 1 4 Specifications 8 Chapter 2 Installation Introduction 10 2 1 General 10 2 2 Encasement List 10 2 3 Installation and Cable Connection 10 2 4 Power 14 2 5 Indicator Lights Introduction 14 Chapter 3 Configuration 15 3 1 Configure connection 15 3 2 Introduction of parameter configuration 15 3 3 Detailed parameters 16 3 3 1 serial port configuration 16 3 3 2 serial port wo...

Page 7: ...e counting function It has been widely used on M2M fields such as electric power intelligent trafic wireless metering industrial automation telemetry water supply environment protection weather and so on 1 2 Features and Benefits Design for Industrial Application High powered industrial LoRa chip and MCU High powered industrial 32 bits CPU Support low power consumption mode including multi sleep a...

Page 8: ...pply 5 I O channels can achieve the analog input of the 3 channels the digital input and output of the 2 channels compatible with the pulse count function of the 2 channels 1 3 Specifications LoRa Specification Item Content Module Industrial LoRa module Communication Frequency Band The product family supports a wide range of frequency bands ISM 903 927MHz Indoor Urban Communication Distance F8L10T...

Page 9: ...l block interface reverse voltage and overvoltage protection Power supply Item Content Standard Power DC 12V 0 5A Power range DC 5 36V Consumption Item Working condition Consumption F8L10T Sleep 3 1 3 2mA 12 VDC Receive data 13 2 13 4mA 12 VDC Transmit data 60 3 61 2mA 12 VDC Sleep 7 3 7 4mA 5 VDC Receive data 26 1 26 2mA 5 VDC Transmit data 107 3 115 1mA 5 VDC Physical Characteristics Item Conten...

Page 10: ... 2 This device will not be sold to the general public it will be sold to dealers only 3 This device requires controlled installation location by professional installers 4 This device requires prfessional configuration for use 5 Be sure to install the original antenna the installation of other antenna it will cause disputes need to bear the relevant legal responsibility 2 2 Encasement List Name Qua...

Page 11: ...nterface of the Device with sign LoRa Warning The cellular antenna and the LoRa antenna can not be connected wrongly And the antennas must be screwed tightly or the signal quality of antenna will be influenced Antenna Installation Instructions 1 Install the antenna far away from the large area metal and ground 2 Keep the antennas visual 3 Minimize obstructions between the antennas 4 Antenna extens...

Page 12: ...om Tel 86 592 5907276 Fax 86 592 5912735 Figure 2 2 Installation antenna mode User Interface Signal Definition Pin Number Signal Name Default Function Extensible Function 1 PWR Power input anode N A 2 GND Power Ground N A 3 GND Power Ground N A 4 RX RS232 RX N A 5 TX RS232 TX N A 6 A RS485 anode N A 7 B RS485 cathode N A 8 IO1 GPIO sleep control 9 IO2 GPIO N A 10 IO3 ADC analog input GPIO ...

Page 13: ...mulas to calculate collected value of ADC Voltage collected value 3 3 20 16 4095 12 1 V Current collected value 3 3 1000 4095 150 mA Installation of cable IP MODEM adopts industrial terminal block interface The recommendatory cable Is 28 16AWG The detail description of standard layout adapter and communication cables as is following Adapter Rating Output 12VDC 0 5A Cable Color Power Output Polarit...

Page 14: ...d user to use the standard DC 12V 0 5A power 2 5 Indicator Lights Introduction The LoRa Terminal provides three indicator lights Power ACT Online Indicator Light State Introduction Power ON LoRa Terminal is powered on OFF LoRa Terminal is powered off ACT BLINK Data is communicating OFF No data Online ON LoRa Terminal has logged on network OFF LoRa Terminal hasn t logged on network F8L10T F8L10T Us...

Page 15: ...in two ways Through the Four Faith configuration software LoRaConfig all configuration is configured with the corresponding entry software interface this configuration is only suitable for professional Installer to facilitate the configuration of PC Case By extending the at command hereinafter referred to as the AT command way to deploy in this configuration the professional Installer only needs t...

Page 16: ...rial port The serial port parameter settings column if the right button is displayed as closed serial That serial port has been opened otherwise please open the serial port The equipment again after power configuration software f8l10t into the configuration state and automatically load the current configuration parameters of equipment in the area on the right side of the display parameters thus ca...

Page 17: ...dule data transmission frequency different hardware modules can work different frequency bands Typical operating frequency band is 903 927 MHz 1000 kHz spacing for a channel Different application areas have different frequency band restrictions as well as different channel interference factors the error rate is different so need to adjust the value according to the actual situation The default val...

Page 18: ...h com Tel 86 592 5907276 Fax 86 592 5912735 In regular sleep keep the device dormant time unit MS when the device sleep over this time will wake up in a normal working state 3 3 7 Debug level Debug level control module log display can be divided into three debugging levels which 0 do not output any log information 1 output Key log information 2 output detailed log information Default 1 ...

Reviews: