background image

F2X14-DK Series IP Modem User Manual

Xiamen Four-Faith Smart Power Technology Co.,Ltd

.

Add

Floor 11, Area A06, No 370, chengyi street, Jimei, Xiamen.China

Page 5 of 33

Hotline

400-8838-199

Tel

0592-6300320

Fax

0592-5912735

https://en.four-faith.net/

Content

Chapter1 Introduction of Product...................................................................................................

7

1.1 General..............................................................................................................................

7

1.2 Product Features...............................................................................................................

7

1.3 Product Specification........................................................................................................

8

Chapter 2 Installation...................................................................................................................

11

2.1 General............................................................................................................................

11

2.2 Encasement List...............................................................................................................

11

2.3 Installation and Cable Connection...................................................................................

11

2.4 Power introduction..........................................................................................................

14

2.5 Indicator...........................................................................................................................

14

Chapter 3 Configuration................................................................................................................

15

3.1 Interface specification.....................................................................................................

15

3.2 Configuration options......................................................................................................

17

3.2.1 “Local serial port Settings”..................................................................................

17

3.2.2 “Local serial port 2 Settings”...............................................................................

17

3.2.3 “DTU Working mode Setting”.............................................................................

17

3.2.4 “GPRS dial parameter setting”.............................................................................

18

3.2.5 “Support platform related Settings”.....................................................................

18

3.2.6

Enterprise gateway related Settings

..............................................................

19

3.2.7 “Multi IP data center”..........................................................................................

19

3.2.8 “Multi connection strategy”.................................................................................

19

3.2.9 “Other configuration”...........................................................................................

20

3.2.10 “ Related settings of network management platform”.......................................

20

3.2.11 “Administrator login Settings”...........................................................................

20

3.2.12 “ICMP parameter setting”..................................................................................

20

3.2.13 “User-defined UDP frame format”....................................................................

20

Summary of Contents for F2 14-DK Series

Page 1: ... is suitable for the following model Model Product Type F2114 DK GPRS IP MODEM F2414 DK WCDMA IP MODEM F2614 DK EVDO IP MODEM F2814 DK FDD LTE IP MODEM Xiamen Four Faith Smart Power Technology Co Ltd Hotline 400 8838 199 Tel 86 592 6300320 Fax 86 592 5912735 Web https en four faith net Add 11th Floor A 06 Area No 370 Chengyi Street Jimei Xiamen Fujian China ...

Page 2: ...yi street Jimei Xiamen China Page 2 of 33 Hotline 400 8838 199 Tel 0592 6300320 Fax 0592 5912735 https en four faith net Files Revised Record Date Version Remark Author 2016 9 27 V1 0 0 Initial version WSP 2017 9 23 V2 0 0 Update the address and add 4G function Faine 2020 4 15 V2 0 0 Contents translation and layout Zoe ...

Page 3: ...echnology Co Ltd Without written permission all commercial use of the files from Four Faith are forbidden such as copy distribute reproduce the files etc but non commercial purpose downloaded or printed by individual all files shall be not revised and the copyright and other proprietorship notice shall be reserved are welcome Trademark Notice Four Faith 四信 are all registered trademarks of Xiamen F...

Page 4: ...r Manual Xiamen Four Faith Smart Power Technology Co Ltd Add Floor 11 Area A06 No 370 chengyi street Jimei Xiamen China Page 4 of 33 Hotline 400 8838 199 Tel 0592 6300320 Fax 0592 5912735 https en four faith net Product appearance ...

Page 5: ...Connection 11 2 4 Power introduction 14 2 5 Indicator 14 Chapter 3 Configuration 15 3 1 Interface specification 15 3 2 Configuration options 17 3 2 1 Local serial port Settings 17 3 2 2 Local serial port 2 Settings 17 3 2 3 DTU Working mode Setting 17 3 2 4 GPRS dial parameter setting 18 3 2 5 Support platform related Settings 18 3 2 6 Enterprise gateway related Settings 19 3 2 7 Multi IP data cen...

Page 6: ...th net 3 3 Read Write configuration 21 3 4 Modification configuration 23 Chapter 4 Use Description 24 4 1 Working mode description 24 4 1 1 DC mode 24 4 2 Connection mode description 24 4 2 1 Long connection mode 24 4 2 2 Short connection mode 25 4 3 Check system and connection status 26 4 4 Remote upgarde 26 4 5 Local serial upgrade 27 Charpter 5 Test 29 5 1 DC Test 29 5 1 1 DCUDP mode 29 5 1 2 D...

Page 7: ...elligent substation intelligent distribution network smart electricity meters intelligent interactive terminal intelligent scheduling intelligent home appliances intelligent electricity building power grids for smart cities intelligent power generation system smart grids Such as new energy storage systems and so on 1 2 Product Features Design for Industrial Application High powered industrial cell...

Page 8: ...t protocol conversion between ModBus and RTU TCP optional Support dual data center backup transmission and multiple data center synchronous transmission 5 data centers Support multi data centers and it can support 1 5 data centers at the same time Support protocol conversion between 101 and 104 optional Support standard TCP UDP protocol support data transfer transparently Support login security au...

Page 9: ...m F2814 DK FDD LTE IP MODEM Standard and Band LTE FDD 2600 2100 1800 900 800MHz 700 1700 2100MHz Optional DC HSPA HSPA HSDPA HSUPA UMTS 850 900 2100MHz 800 850 1900 2100MHz Optional EDGE GPRS GSM 850 900 1800 1900MHz GPRS CLASS 10 EDGE CLASS 12 Bandwidth LTE FDD Download speed100Mbps Upload speed 50Mbps DC HSPA Download speed42Mpbs Upload speed 5 76 Mbps HSPA Download speed21Mpbs Upload speed 5 76...

Page 10: ... https en four faith net Power supply Item Content Standard power DC 12V 0 5A Power range DC 5 36V Consumption Item Content Communication 45 90mA 12VDC Standby 10 15mA 12VDC Physical Characteristics Item Content Housing Metal IP30 Dimension 110x85x32mm Except antenna Weight About 290 g Other parameters Item Content Working temperature 40 75ºC 40 167 Storage temperature 40 85ºC 40 185 Relative humi...

Page 11: ...For transport safely proper packaging IP MODEM is usually required Please take good care of the packing materials when you unpack so that they can be used for future transportation IP MODEM include below components IP MODEM host 1 pcs According to customer s order User manual 1 pcs Car antenna 1 pcs SMA male interface Wiring terminal 1 pcs 8 pin 3 5mm Three core wiring line with terminal which use...

Page 12: ...320 Fax 0592 5912735 https en four faith net Antenna and SIM card installation IP MODEM antenna interface is for SMA female interface Rotate the SMA male header to the antenna interface of IP Modem make sure that the connection is good so as not to affect the signal quality When the SIM card is removed remove the SIM card block first When the SIM card is installed make sure the card is in place ...

Page 13: ... 6300320 Fax 0592 5912735 https en four faith net Terminal block definition 3 5mm interval 8PIN PIN Definition Description 1 V Power negative 2 V Power positive 3 TXD RS232 sending end of F2X14 DK 4 GND For signa 5 RXD RS232 receiving end of F2X14 DK 6 RXD2 Extended serial port 2 of F2X14 DK for receiving RS485_A 7 TXD2 Extended serial port 2 of F2X14 DK for sending RS485_B 8 GND For signal ...

Page 14: ...ater than 4W 12VDC 0 5A power supply is recommended 2 5 Indicator IP MODEM provides four indicators definition as below Power Module SIM Status States of indicators is as follows Through display of indicator light the user can see the system and connection status No Power Module SIM Status Definition Power Network SIM Card Operat ion 1 ON X Flash alternately Module is on and at AT mode 2 ON X OFF ...

Page 15: ...RS232 serial port line connect F2X14 DK to computer power on after chosing right serial configuration parameters the serial port can be used for system parameter configuration Note The configuration page can be entered with baudrates of 115200 and 8N1 in the first 3 seconds after booting Open configuration tool F2x14d_Soft15031718 exe showing as below Open the configuration tool after chosing righ...

Page 16: ...ts of the current PC these serial ports are listed in the select serial port Please be patient when you click this item because it is slow to automatically identify the currently available serial port please select the serial port that was connected to F2X14 DK and chose right parameter which be used Check the auto option configuration software can automatically detect the parameters that match th...

Page 17: ...9600 14400 19200 38400 57600 115200 bps Option 115200 Default Serial port data bits 8 Serial port stop bits 1 1 5 2 Option Serial port parity bits None odd Even Local serial port scan interval 100 ms 10 Default Packet response timeout seconds 5 Default Local serial port frame size bytes 1024 Default set optionally Range 10 1024 3 2 2 Local serial port 2 Settings Serial port baud rate 1200 2400 480...

Page 18: ...mode and when the time is up the network will be reconnected to realize the timing activation function Range 0 1440 Timing offline interval minutes According to this time the network will be unblocked and restarted value is 0 means the time is infinite Generally fill in 0 range 0 60 Whether the data flow and business flow are separated Yes Note In the state of short connection open at least one ac...

Page 19: ...ction mode TCP UDP DCTCP DCUDP Option Maximum number of retransmission allowed for transmission failure 0 TCP protocol retransmission utomatically Enterprise gateway heartbeat interval minutes Time interval of heartbeat pack range 1 60 DNS IP1 0 0 0 0 or fill in private domain name resolution server address DNS IP2 0 0 0 0 3 2 7 Multi IP data center When chose multi centers mode fill in the IP add...

Page 20: ...identify the device 15 bit string Factory defined can not be modified Working mode Only SMS mode SMS plus IP mode or disabled List of trust Numbers Only receive user SMS of trust list if the list is empty SMS from any user can be accepted Device number Device identification of gateway platform Factory defined can not be modified Gateway platform address IP address and port number of gateway platfo...

Page 21: ...frame For the enterprise gateway connection mode is pure UDP UDP drop out and response frame For the enterprise gateway connection mode is pure UDP Note This configuration is only valid if the enterprise gateway connection is pure UDP the login frame and the login response frame must be configured at the same time as well as other frames The purpose is to enable the enterprise gateway to know abou...

Page 22: ... download configuration also needs hardware detection is normal and log in as an administrator after the user has set the parameters click Download configuration if this step is successful Download configuration successfully will be displayed in the log contents information bar a prompt dialog box will pop up at the same time asks if you need to restart for the parameter to take effect immediately...

Page 23: ...nal configuration modify the corresponding configuration parameters and then write configuration to modify the required parameters Or you can export and save the configuration information on the first write to the configuration When you need to modify the configuration enter the save file then modify the corresponding configuration parameters and then write the configuration There is a default con...

Page 24: ... bottom device and the data center can be realized Function As a communication bridge between the bottom equipment and the data center Such as RTU PLC etc the data sent by the bottom device to the serial port is encapsulated into network packets and sent to the data center and he data from the data center can also be sent to the bottom device through the serial port 4 1 Working mode description 4 ...

Page 25: ...es 1 60 Note In this connection mode at least one of the three activation modes must be on In this connection mode users can control when to connect and when to disconnect For example set Timing off line interval 55 Timing activate interval 600 Phone activation open Local data activation close after networking it will automatically log off and enter the waiting activation state after 5 minutes wit...

Page 26: ...ot connected 6 ON X Flash in the same time APP is normal MP is normal WMMP is normal Note 1 ON means LED always bright hold for at least 3 seconds 2 OFF means LED always off hold for at least 3 seconds 3 Flash slowly means flash frequency is about 1 S If the center doesn t open it defaults to be normal state 4 4 Remote upgarde If you need to upgrade the program remotely please contact us to get th...

Page 27: ...graded ver Software version that needs to be upgraded For example 123456 RMTUPGRADE 00 0 16 120 42 46 98 9991 F2X64 STANDARD V1 0 1 Command STPUPGRADE Function Cancel this uograde Parameter None For example 123456 STPUPGRADE 4 5 Local serial upgrade 1 Open DTUDowanLoad exe multiplex download tool what our company provide Chose upgrade program file use RS232 serial port line to connect F2X14 DK to ...

Page 28: ...d Floor 11 Area A06 No 370 chengyi street Jimei Xiamen China Fax 0592 5912735 Tel 0592 6300320 Page 28 of 33 Hotline 400 8838 199 https en four faith net 3 When the upgrade is complete the red box showing as below will be displayed in the interface 4 Close download tool restart the device ...

Page 29: ...itions before your test 1 A computer with Internet access run the test software F2X14D_DC exe on this computer in order to listen for a certain TCP UDP port for communication 2 Use RS232 serial port line to connect the device to the computer 3 A SIM card that has already open data service 5 1 DC Test 5 1 1 DCUDP mode Open F2X14D_DC exe showing as below Working mode must be configurated to DCUDP Co...

Page 30: ... you want to open it again click Control Start service button to start listening on the port 3 When the device connect to data center successfully local device number login time corresponding IP information will list in the window showing as below 4 You can test communication with data center now Data that data center received will show up in infomation window Data that data center send will recei...

Page 31: ...ith net Data can be sent to the specified port through the center software Select the device number you want to send from the list local device number will be displayed in the corresponding window at the bottom and input data in the bottom of the right window click Send button data will be send out by software showing as below Data was sent by the center to the corresponding device will display in...

Page 32: ...imei Xiamen China Fax 0592 5912735 Tel 0592 6300320 Page 32 of 33 Hotline 400 8838 199 https en four faith net 5 1 2 DCTCP mode test Open test tool F2X14D_DC exe click TCP to enter TCP mode F2X14D_DC exe will work on TCP mode at this moment you can start test if you config the device to DCTCO mode Test steps is similar to UDP mode ...

Page 33: ...to the remote server Solution 1 Check parameter of F2X14 DK is right or not 2 Check SIMcard is insert correctly or not make sure the SIM card is not stopped Can be tested by dialing the card number 3 If the remote data server is within the LAN check that firewall port mapping Settings are correct or not Question 4 Unable to transmit data to field control equipment when connect to server data manag...

Reviews: