Foster FKS 10-4 Technical Manual Download Page 12

CONDENSING UNIT TECHNICAL

 DA

TA

 

 

 

 

Receiver** 

HP

 

LP

 

 

  

 

 

*Max 

Max  

 

Cond  

Air  

 

***Unit  

Net 

 

Dimensions 

Liquid 

Suction

Model 

Nom

 

Refrigerant 

Gas

 

Capacity 

Setting 

Setting 

   Electrical supply       

 

*Abs 

   *Nom  

   Run 

Start

 

Fuse 

Fan Motor  

V

olume

 

Absorbed  

  Noise 

 k

gs

 

Ht x w x d 

Line 

Line

 

hp

 

 

Charge

 

Its 

Bar 

Bar 

V

olts 

    Phase 

Hz 

Kw

 

Amps 

Amps 

Amps

 

Rating 

x mm 

m3/hr

 

W

atts 

Level dBa 

W

eight

 

 mm 

mm 

mm

NOTE:

* Based on 40°C condensing temperature. ** Based on 80% liquid capacity at 40°C condensing temperature. *** Based on 3 metres from front of unit, 1.5 metres from fl

oor level.

DCU1-1H 

0.5 

R 404a 

1.00 

1.6 

28 

0.2 

230 

50 

0.5 

3.2 

6.3 

19 

13 

1 x 250 

750 

1 x 90 

59 

39 

368 x 660 x 330 

10 

12

DCU2-1H 

0.75 

R 404a 

1.00 

1.6 

28 

0.2 

230 

50 

0.7 

3.7 

7.8 

31 

20 

1 x 250 

750 

1 x 90 

60 

43 

368 x 660 x 330 

10 

16

DCU3-1H 

R 404a 

1.60 

2.5 

28 

0.2 

230 

50 

1.1 

5.1 

11.3 

32 

20 

1 x 300 

1400 

1 x 90 

60 

61 

458 x 880 x 400 

10 

16

DCU4-3H 

1.8 

R 404a 

2.00 

2.5 

28 

0.2 

400 

50 

1.7 

3.6 

6.6 

18 

16 

1 x 330 

1500 

1 x 120 

62 

62 

458 x 880 x 400 

10 

16

DCU5-3H 

2.3 

R 404a 

2.00 

2.5 

28 

0.2 

400 

50 

2.1 

4.4 

8.1 

25 

20 

1 x 330 

1500 

1 x 120 

63 

64 

458 x 880 x 400 

10 

22

DCU6-3H 

R 404a 

6.00 

6.5 

28 

0.2 

400 

50 

3.2 

6.2 

9.7 

27 

20 

1 x 400 

3100 

1 x 160 

64 

102 

595 x 1075 x 532 

10 

22

DCU1-1L

 

0.75 

R 404a 

1.50 

1.6 

28 

0.2 

230 

50 

0.8 

3.8 

28 

16 

1 x 250 

750 

1 x 90 

60 

46 

368 x 660 x 330 

10 

16

DCU2-1L

 

1.8 

R 404a 

1.60 

2.5 

28 

0.2 

230 

50 

1.4 

8.6 

16 

40 

20 

1 x 300 

1400 

1 x 90 

60 

60 

458 x 880 x 400 

10 

22

DCU3-3L

 

2.3 

R 404a 

1.60 

2.5 

28 

0.2 

400 

50 

1.8 

4.5 

6.2 

25 

16 

1 x 300 

1400 

1 x 90 

61 

65 

458 x 880 x 400 

10 

22

DCU4-3L

 

R 404a 

2.00 

2.5 

28 

0.2 

400 

50 

1.8 

4.8 

5.8 

30 

20 

1 x 350 

1500 

1 x 120 

61 

73 

458 x 880 x 400 

10 

22

DCU5-3L

 

R 404a 

6.00 

6.5 

28 

0.2 

400 

50 

3.8 

7.9 

12.7 

71 

25 

1 x 400 

3100 

1 x 160 

68 

120 

595 x 1075 x 532 

10 

28

DCU6-3L

 

7.5 

R 404a 

10.00 

12 

28 

0.2 

400 

50 

5.8 

12 

24.8 

80 

25 

1 x 450 

3100 

1 x 160 

72 

187 

654 x 1575 x 642 

12 

35

Duet Package Wiring Schematic

Fig 1.

Fig 2.

Fig 3.

Supply In: 400v—50—3

Control Panel

HP/LP Condenser Fan Pressure Switch

1mm

2

 3 core

Crankcase Heater – 1mm

2

 3 core

(Optional)

Interconnecting  Cables  for  three  phase  supply 

Condensing Unit

Unit Cooler

Evaporator Fan — 1mm

2

 3 core

Defrost Heaters (if fitted) – 1mm

2

 5 core

Drain Line Heater – 1mm

2

 3 core

Wiring Diagram 

00-838106-00 

(See page 11 for model reference)

Compressor/Fan – 2.5mm

2

 5 core

Supply In: 400v—50—3 + N

Control Panel

HP/LP Condenser Fan Pressure Switch

1mm

2

 3 core

Crankcase Htr. – 1mm

2

 3 core

(Optional)

Interconnecting  Cables  for  three  phase  supply 

Condensing Unit

Unit Cooler

Liq. Line Solenoid — 1mm

2

 3 core

Evaporator Fan — 1mm

2

 3 core

Defrost Heater (if fitted) – 1mm

2

 5 core

Drain Line Heater – 1mm

2

 3 core

Wiring Diagram 

00-838359-00

 

 

00-838362-00

(See page 11 for model reference)

Compressor/Fan – 2.5mm

2

 5 core

Supply In: 230v—50—1 + N

Control Panel

HP/LP Switch — 1mm

2

 3 core

(Optional Condenser Fan Pressure Switch)

Crankcase Heater – 1mm

2

 3 core

(Optional)

Interconnecting  Cables  for  single  phase  supply 

Condensing Unit

Unit Cooler

Evaporator Fan — 1mm

2

 3 core

Defrost Heaters (if fitted) – 1.5mm

2

 3 core

Drain Line Heater – 1mm

2

 3 core

Wiring Diagram 

00-838099-00

 

(off cycle 

defrost)
 

 

00-838101-00, 00-838102-

00

Compressor/Fan – 2.5mm

2

 5 core

Liquid Line Solenoid — 1mm

2

 3 core

Liquid Line Solenoid — 1mm

2

 3 core

12

5

Condensing Unit W

all Brackets 

The wall brackets are supplied in two sizes. 

The fi

rst bracket part number 00-876220-01, size 900 x 430 is used on models :- DCU1-1 H, DCU 2-1 H, DCU 3-1 H, DCU 4-3H, DCU 5-3H, 

DCU 6-3H, DCU 1-1L, DCU 2-1L, DCU 3-3L, DCU 4-3L. 

The second bracket part number 00-876221-01, size 1200 x 600 is used on models ;- DCU 5-3L, DCU6-3L. 

The brackets should be fi

tted approximately 150mm from each end of the unit at a height determined by site conditions. 

Impor

tant 

Allow adequate space around the unit for air circulation and easy removal of panels for service requirements 

Summary of Contents for FKS 10-4

Page 1: ...T e c h n i c a l M a n u a l Duet Condensing Unit Cooler ...

Page 2: ...al management Product Support and Installation contractors are required to 1 Ensure that wherever possible waste is removed from the client s site where arrangements are in place all waste should be retumed to Foster Refrigerator s premises In certain circumstances waste may be disposed of on the clients site if permission is given if the client has arrangements in place for the type of waste 2 If...

Page 3: ...defrost heaters FKS Range with and without defrost heaters Control Panel Microprocessor Controller c w function indicators Ten metre sensing probes Component contactors Component circuit breakers Not included Interconnecting pipework Pipe installation Mechanical fasteners screws pipe clamps etc Refrigerant Mains supply wiring Lockable isolator switch White enclosure Remote alarm contacts Ancillari...

Page 4: ...4 Cooler Specification ...

Page 5: ... 50 3 2 6 2 9 7 27 20 1 x 400 3100 1 x 160 64 102 595 x 1075 x 532 10 22 DCU1 1L 0 75 R 404a 1 50 1 6 28 0 2 230 1 50 0 8 3 8 7 28 16 1 x 250 750 1 x 90 60 46 368 x 660 x 330 10 16 DCU2 1L 1 8 R 404a 1 60 2 5 28 0 2 230 1 50 1 4 8 6 16 40 20 1 x 300 1400 1 x 90 60 60 458 x 880 x 400 10 22 DCU3 3L 2 3 R 404a 1 60 2 5 28 0 2 400 3 50 1 8 4 5 6 2 25 16 1 x 300 1400 1 x 90 61 65 458 x 880 x 400 10 22 ...

Page 6: ...FKS Cooler Dimensions 6 ...

Page 7: ... pipe size should be determined by application Recommended maximum vertical change 5 metres The suction lines have been selected to achieve a pressure drop of 2psi or less whilst maintaining refrigerant velocity in the horizontal plane of 3 5m s 700ft min and in the vertical plane of 7 0m s 1500ft min to achieve oil return Model 43 C Ambient Liquid Line Pipe Size Suction Line Pipe Size Horizontal ...

Page 8: ... a single line appears on the display for 3 seconds to indicate the autotest period After this period the air temperature measured by the T1 probe is displayed It is strongly advised that before adjusting any Service Parameters a thorough understanding of the following instructions should be obtained LDU 15 CONTROLLER lae aux Check temperature set point Check set point by pressing the set button T...

Page 9: ...is 1 30 mins dEF is displayed during defrost and until the set time has elapsed after defrosting or until air temperature falls below the value setpoint hysteresis dtY Defrost type FAn Off cycle defrost ELE Electric heater defrost GAS Hot gas defrost doP Defrost optimisation con At regular intervals of drE hrs Acc Defrost timer only runs while evaporator temperature is below 0 C defrosting occurs ...

Page 10: ...lternate between ALM and air temperature while the alarm condition persists Display Parameter LDU151E B Duet High Temp Default Values Used in Panels F H L SCL Readout Scale 2 C 2 C SPL Minimum Temperature Set Point 05 0 SPH Maximum Temperature Set Point 01 8 SP Effective Temperature Set Point 03 2 HYS Hysteresis 3 3 CRT Compressor Rest Time minutes 10 2 CDC Compressor Regulation with T1 Fail 20 7 ...

Page 11: ... 23 24 25 26 DUET C F M L AND IC SERIES 00 OFF 01 Te FrS 02 Always ON Units Deg Deg Deg Min Min Sec Hrs Deg Min Min Min Flag Flag Min Deg Flag Deg Deg Min Flag Deg Deg Deg Flag 01 Mnemonic SPL SPh hYS coF con cdc crS drE dLi dto drP diS dtY doP Fct FrS Fid ALo Ahi AdL Ain oS1 oS2 oS3 SiM Adr Min Limit 50 SPL 01 00 00 00 00 01 01 00 00 01 FAn con 01 50 00 50 SPh 01 01 20 20 20 00 1 ELE 00 01 00 02 ...

Page 12: ...Cables for three phase supply Condensing Unit Unit Cooler Liq Line Solenoid 1mm2 3 core Evaporator Fan 1mm2 3 core Defrost Heater if fitted 1mm2 5 core Drain Line Heater 1mm2 3 core Wiring Diagram 00 838359 00 00 838362 00 See page 11 for model reference Compressor Fan 2 5mm2 5 core Supply In 230v 50 1 N Control Panel HP LP Switch 1mm2 3 core Optional Condenser Fan Pressure Switch Crankcase Heater ...

Page 13: ... of an oil separator should be considered especially on low temperature applications plus the position of the oil P trap and the size of the suction line to maximise oil return to the compressor 4 EVAPORATORS COOLERS FTG Range Ceiling Mounted These are used for small coldroom applications and are available for both high and low temperature conditions The low temperature models have defrost heaters...

Page 14: ...r Oldmedow Road King s Lynn Norfolk PE30 4JU England Tel 01553 691122 Fax 01553 691447 Website www fosterrefrigerator co uk E mail sales foster uk com a Division of ITW UK Ltd DUET TM 05 05 T e c h n i c a l M a n u a l ...