5  

 
Air Temperature Probe Failure. 
 

Will be displayed. 

The alarm will sound but can be silenced by pressing any button. 
There is no further action that can be taken by the user in this instance. During this period the unit will continue to 
operate but have a reduced performance. 

Action: 

Replace Probe. 

 

Evaporator Temperature Probe Failure. (Automatic Defrost Cabinets Only)

 

 

Will be displayed. 

The alarm will sound but can be silenced by pressing any button. 
There is no further action that can be taken by the user in this instance. During this period the unit will continue to 
operate satisfactorily, but this failure will have an effect on the defrost and therefore efficiency if allowed to 
continue. 

Action: 

Replace Probe. 

 

Information Menu

 

 
Pressing and releasing 

activates the information menu. From this menu you can display the 

temperature relating to T1 (air probe), T2 (evaporator probe, if fitted) and T3 (condenser probe, if fitted). 
The maximum temperature (THI) and the minimum temperature (TLO) the cabinet has achieved since it was last 
re-set. 
The total operating time of the condenser (CND), since it was last cleaned, and the keyboard status (LOC). 
 
The information to be displayed can be selected sequentially by pressing 

repeatedly or scrolling 

 
through the menu using the 

or 

buttons. 

 
Once selected press 

to display the value 

 
Exit from the info menu by pressing 

or is automatic after 6 seconds if no buttons are pressed. 

 

To reset the temperature settings recorded in THI and TLO and the hours counted in CND, access the info  
 
menu press 

to display the value plus  

simultaneously for resetting to be completed. 

 
To check the LOC status scroll through to LOC, press 

to display status 

– YES to lock keys. – NO to 

leave keys accessible. 
NOTE: with the keys locked it is not possible to turn the unit OFF or ON or to check the set point 

 
Parameter Setting and Adjustment

 

 

It  is  strongly  advised  that  before  adjusting  any  Service  Parameters  a  thorough  understanding  of  the 
following instructions should be obtained. 

 
The parameters are accessed by pressing the following keys in

 

succession  

+  

“set”

 + 

and 

keeping them pressed for 5 seconds.  

 

After this period the first parameter 

„SCL‟

 will be displayed. 

 

 
Press button 

to pass from one parameter to the next and button 

to go back. 

 
Press 

to display the value + 

or 

to change it. 

 
Exit from set up is by pressing 

or is automatic if no buttons are pressed for 30 seconds 

 

NOTE:  

When receiving a replacement controller the unit will be set with the default settings. Change the settings to those 
relating to the particular model. After changing parameter „SCL‟ from „1‟ to „2‟ moving through parameters „SPL‟, 
„SP‟, „FDD‟, IISL‟ and  „IISP‟ you may find that „-or‟ will be displayed. „-or‟ indicates that the control setting is out of 
range. 
 
To get the parameter back into range, for example „SPL‟, press 

to display the value + 

E2 

E1 

Summary of Contents for LL1/2H

Page 1: ...Foster Low Level Counters with LCD28 Controller Service Manual Re Issued Version July 2010 ISO 14001 ISO 9001...

Page 2: ...formation Make sure the power supply is turned off before making any electrical repairs To minimise shock and fire hazards please do not plug or unplug the unit with wet hands During maintenance and c...

Page 3: ...w Guidance is available from the Environment Agency on how to comply with the waste management duty of care 3 The following waste must be stored of separately from other wastes as they are hazardous t...

Page 4: ...70x368 566x670x139 357x570x487 566x670x139 566x670x368 566x670x139 Nett Capacity litres 140 140 222 140 279 279 Number of Drawers 1 2 2 2 4 2 Maximum Weight Load per drawer 40kg 40kg 40kg 40kg 40kg 40...

Page 5: ...al operating temperature will automatically cancel the alarm Possible Causes Evaporator fan not working Restricted airflow through airduct Evaporator iced up Compressor not working Low temperature ala...

Page 6: ...ay the value Exit from the info menu by pressing or is automatic after 6 seconds if no buttons are pressed To reset the temperature settings recorded in THI and TLO and the hours counted in CND access...

Page 7: ...n cycle with PF1 0 10 6 min 6 cSd Compressor Stop delay after door open 0 30 1 min 1 dFr Defrost frequency I 0 24 3 1 24h 4 dLi Defrost end temperature 30 30 15 C 20 dto Maximum defrost duration 1 120...

Page 8: ...g NO oS3 Condenser Probe offset 12 5 12 5 0 K 0 tLd Logging Temp Delay 1 30 5 min 5 Sim Display slowdown 0 100 3 exp 3 Adr Unit address 1 255 1 exp 1 Unit Diagrams Standard Low Level Counter Condensin...

Page 9: ...t the condensing unit Check the insulation of the thermostat If problem persists change the thermostat Control contacts are stuck closed Change the control Check amperage load Defective or incorrect t...

Page 10: ...er are tightened The evaporator and or condenser fans are loose Check if the fans are securely fastened Also check if the fan blades are loose broken or crooked If so change the faulty blade Compresso...

Page 11: ...y Ensure gaskets are snapped in completely Remove gasket and wash with soap and water Check condition of gasket replace if necessary Dirty condenser coil Clean condenser coil Evaporator coil iced over...