Shelf Manager CLI
Fortinet Technologies Inc.
# clia activate 90 0
Pigeon Point Shelf Manager Command Line Interpreter
Command issued via IPMB, status = 0 (0x0)
Command executed successfully
alarm
clia alarm [clear | info| minor | major | critical]
This command provides access to the TELCO alarm outputs.
Enter
clia alarm
without parameters to view the current status of TELCO alarm outputs:
# clia alarm
Pigeon Point Shelf Manager Command Line Interpreter
alarm mask: 0x00
Alarm mask 0x00 means no alarm.
Clearing alarms
Enter
clia alarm clear
to clear the minor and major alarm outputs. By default, critical alarm outputs can be
cleared because the
shelfman.conf
file contains the following lines:
# ALLOW_CLEARING_CRITICAL_ALARM: This parameter of boolean type enables the
# ability to clear the critical alarm condition without the alarm cutoff
# button. Default is FALSE.
#
ALLOW_CLEARING_CRITICAL_ALARM = TRUE
If you change
ALLOW_CLEARING_CRITICAL_ALARM
to
FALSE
the
clia alarm clear command
does not
clear critical alarms.
Enter
clia alarm info
to display information about the last alarm that occurred:
# clia alarm info
Pigeon Point Shelf Manager Command Line Interpreter
Last saved alarm information:
Alarm mask: 0x00
Alarm date/time: Sun Jun 8 21:56:47 2009
Alarm source: Schroff Carrier
Alarm reason: Cooling state alert
Clearing the alarm changes the information displayed by the
clia alarm
command but not
the information displayed by the
clia alarm info
command
FortiGate-5144C 6.2.3 Chassis Guide
45