![Fortinet FortiAP S322CR Information Download Page 10](http://html.mh-extra.com/html/fortinet/fortiap-s322cr/fortiap-s322cr_information_2322204010.webp)
Cautions and Warnings
Environmental Specifications
Refer to specific Product Model Data Sheet for Environmental
Specifications (Operating Temperature, Storage Temperature,
Humidity, and Altitude).
Safety
Grounding — To prevent damage to your equipment, connections
that enter from outside the building should pass through a
lightning / surge protector, and be properly grounded. Use
an electrostatic discharge workstation (ESD) and/or wear an
anti-static wrist strap while you work. In addition to the grounding
terminal of the plug, on the back panel, there is another, separate
terminal for earthing.
Mise à la terre — Pour éviter d’endommager votre matériel,
assurez-vous que les branchements qui entrent à partir de l’ex-
térieur du bâtiment passent par un parafoudre / parasurtenseur
et sont correctement mis à la terre. Utilisez un poste de travail
de décharge électrostatique (ESD) et / ou portez un bracelet
anti-statique lorsque vous travaillez. Ce produit possède une
borne de mise à la terre qui est prévu à l’arrière du produit, à ceci
s’ajoute la mise à la terre de la prise.
Power over Ethernet (PoE) — Do not connect this device to PoE
networks with routing to the outside plant. Use this equipment
in a Network Environment 0 per IECTR 62101. Do not use PoE
injectors that are not IEEE 802.3af compliant. They may damage
your device.
Alimentation par Ethernet — Ce matériel doit être utilisé dans
un Environnement Réseau 0 par IECTR 62101. Ce matériel est
uniquement connecté aux réseaux PoE sans installation externe
de routage. Cet appareil est conforme aux normes IEEE 802.3af.
Ne pas utiliser d’autres injecteurs d’alimentation non conformes
sous peine d’endommager votre matériel.
The connecting cable between the outdoor equipment and the
indoor ITE devices should comply with Class 3 wiring methods as
listed in NEC, Table 725.154(G) for Class 3 Cable Substitutions
Le câble connectant l’équipement extérieur et ceux d’intérieur
de type ITE doit être conforme avec les méthodes de câblage
de classe 3 tel que listé dans le standard NEC, Table 725.154(G)
pour les câbles de substitutions de classe 3.
This product has a separate protective earthing terminal provided
on the back of the product in addition to the grounding terminal
of the attachment plug. This separate protective earthing terminal
must be permanently connected to earth with a green with yellow
stripe conductor minimum size # 14 AWG and the connection is
to be installed by a qualified service personnel.
Ce produit possède une borne de mise à la terre qui est prévu à
l’arrière du produit, à ceci s’ajoute la mise à la terre de la prise.
Cette séparation protège la borne de mise à la terre qui doit être
en permanence reliée au conducteur à rayure verte et jaune de
taille minimum #14 AWG. Seul un technicien qualifié est autorisé à
effectuer le raccordement.
Regulatory Compliance
Federal Communication Commission (FCC) – USA
This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equip-
ment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. How-
ever, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful inter-
ference to radio or television reception, which can be determined
by turning the equipment off and on, the user is encouraged to try
to correct the interference by one of the following measures:
1. Reorient or relocate the receiving antenna.
2. Increase the separation between the equipment and receiver
3. Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
4. Consult the dealer or an experienced radio/TV technician
for help.
FCC Caution: Any changes or modifications not expressly
approved by the party responsible for compliance could void the
user’s authority to operate this equipment.
This device complies with Part 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause
undesired operation.
This transmitter must not be co-located or operating in conjunc-
tion with any other antenna or transmitter.
The antenna must be installed vertically as described in the
manual for all outdoor use condition for ensuring that all emission
above 30 degree elevation will not exceed FCC 21dBm eirp limit.
This device meets all the other requirements specified in Part 15E,
Section 15.407 of the FCC Rules.
IMPORTANT NOTE:
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set
forth for an uncontrolled environment. This equipment should be
installed and operated with minimum distance 42cm between the
radiator & your body.
Industry Canada Equipment Standard for Digital
Equipment (ICES) – Canada
CAN ICES-3 (B) / NMB-3 (B)
This device complies with RSS-247 of the Industry Canada Rules.
Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that
may cause undesired operation.
Ce dispositif est conforme à la norme CNR-247 d’Industrie
Canada applicable aux appareils radio exempts de licence.
Son fonctionnement est sujet aux deux conditions suivantes:
(1) le dispositif ne doit pas produire de brouillage préjudiciable,
et (2) ce dispositif doit accepter tout brouillage reçu, y compris
un brouillage susceptible de provoquer un fonctionnement
indésirable.
Caution :
(i) the device for operation in the band 5150-5250 MHz is only
for indoor use to reduce the potential for harmful interference to
co-channel mobile satellite systems;
(ii) the maximum antenna gain permitted for devices in the bands
5250-5350 MHz and 5470-5725 MHz shall be such that the
equipment still complies with the e.i.r.p. limit;
(iii) the maximum antenna gain permitted for devices in the band
5725-5850 MHz shall be such that the equipment still complies
with the e.i.r.p. limits specified for point-to-point and non-point-to-
point operation as appropriate; and
(iv) the worst-case tilt angle(s) necessary to remain compliant with
the e.i.r.p. elevation mask requirement set forth in Section 6.2.2(3)
shall be clearly indicated.
(v) Users should also be advised that high-power radars are
allocated as primary users (i.e. priority users) of the bands 5250-
5350 MHz and 5650-5850 MHz and that these radars could
cause interference and/or damage to LE-LAN devices.
Avertissement:
Le guide d’utilisation des dispositifs pour réseaux locaux
doit inclure des instructions précises sur les restrictions
susmentionnées, notamment :
(i) les dispositifs fonctionnant dans la bande 5150-5250 MHz
sont réservés uniquement pour une utilisation à l’intérieur afin de
réduire les risques de brouillage préjudiciable aux systèmes de
satellites mobiles utilisant les mêmes canaux;
(ii) le gain maximal d’antenne permis pour les dispositifs utilisant
les bandes de 5250 à 5 350 MHz et de 5470 à 5725 MHz doit
être conforme à la limite de la p.i.r.e;
(iii) le gain maximal d’antenne permis (pour les dispositifs utilisant
la bande de 5 725 à 5 850 MHz) doit être conforme à la limite de
la p.i.r.e. spécifiée pour l’exploitation point à point et l’exploitation
non point à point, selon le cas;
(iv) les pires angles d’inclinaison nécessaires pour rester
conforme à l’exigence de la p.i.r.e. applicable au masque
d’élévation, et énoncée à la section 6.2.2 3), doivent être
clairement indiqués.
(v) De plus, les utilisateurs devraient aussi être avisés que
les utilisateurs de radars de haute puissance sont désignés
utilisateurs principaux (c.-à-d., qu’ils ont la priorité) pour les
bandes 5250-5350 MHz et 5650-5850 MHz et que ces radars
pourraient causer du brouillage et/ou des dommages aux
dispositifs LAN-EL.
Radiation Exposure Statement:
This equipment complies with IC radiation exposure limits set
forth for an uncontrolled environment. This equipment should be
installed and operated with minimum distance 42cm between the
radiator & your body.
Déclaration d’exposition aux radiations:
Cet équipement est conforme aux limites d’exposition aux ray-
onnements IC établies pour un environnement non contrôlé. Cet
équipement doit être installé et utilisé avec un minimum de 42cm
de distance entre la source de rayonnement et votre corps.
European Conformity (CE) - EU
This is a Class B product. In a domestic environment, this product
may cause radio interference, in which case the user may be
required to take adequate measures.
Professional installation instruction
1. Installation personal
This product is designed for specific application and needs to
be installed by a qualified personal who has RF and related rule
knowledge. The general user shall not attempt to install or change
the setting.
2. Installation location
The product shall be installed at a location where the radiating an-
tenna can be kept 42cm from nearby person in normal operation
condition to meet regulatory RF exposure requirement.
3. External antenna
Use only the antennas which have been approved by the man-
ufacturer. The non-approved antenna(s) may produce unwanted
spurious or excessive RF transmitting power which may lead to
the violation of FCC/IC limit and is prohibited.
4. Installation procedure
Please refer to user’s manual for the detail.
5. Warning
Please carefully select the installation position and make sure
that the final output power does not exceed the limit set force
in relevant rules. The violation of the rule could lead to serious
federal penalty.
Instructions d’installation professionnelle
1. Installation
Ce produit est destine a un usage specifique et doit etre installe
par un personnel qualifie maitrisant les radiofrequences et les
regles s’y rapportant. L’installation et les reglages ne doivent pas
etre modifies par l’utilisateur final.
2. Emplacement d’installation
En usage normal, afin de respecter les exigences reglementaires
concernant l’exposition aux radiofrequences, ce produit doit
etre installe de facon a respecter une distance de 42cm entre
l’antenne emettrice et les personnes.
3. Antenn externe.
Utiliser uniiquement les antennes approuvees par le fabricant.
L’utilisation d’autres antennes peut conduire a un niveau de
rayonnement essentiel ou non essentiel depassant les niveaux
limites definis par FCC/IC, ce qui est interdit.
4. Procedure d’installation
Consulter le manuel d’utilisation.