FORTEZA JSC
FORTEZA RS-BL
Please visit our internet sites:
2.2.2. While the battery is being discharged, the indicators RS and BL will light in
succession.
In order to avoid deep discharge of the battery and, as the consequence, reduction of
its life cycle, it is necessary to disconnect the battery (press the button one more time). If it is
necessary to continue the operation, the power should be provided to the terminals as per
Paragraph 2.2.3.
In order to charge the battery, it is necessary to connect the standard +5V network
adapter with the permissible current load no less than 500 мА.
After the charging is completed, the CHG will turn off.
2.2.3. It is possible to feed the converter from an external source of 8…30 V. The
external source must be connected to the terminals “ + ” and ” – “.
2.2.4. For connecting the control panel to the detector with the help of wire connection
it is necessary to do the following:
- Connect the FMC – RS cable (it is applied in a set) to the RS converter’s terminals
“a-b” (a red wire – a, black – b);
- Connect the plug of the FMC – RS cable to the detector’s RS-485 socket;
- Connect the micro USB – USB cable to the socket of the USB converter RS-USB;
- Connect the opposite cable plug to the PC’s USB port or to the Android device;
- Wait till the drive activates (working with “Windows”);
- Activate the application.
3. The manufacturer’s guarantee certificate
The
manufacturer
guarantees
the
conformity
of
the
converter
RS-BL No ______________ to the conditions, provided in this manual and is considered
suitable for operation.
Date of issue ______________ 201
The guarantee operation period is 12 months as of the date of dispatch by the
manufacturer.