FORTEZA JSC 

                         

       FORTEZA RS-BL 

 
 

Please visit our internet sites:                        

www.forteza.com

    or    

www.forteza.eu

                   Page 7 

 

2.2.2.  While  the  battery  is  being  discharged,  the  indicators  RS  and  BL  will  light  in 

succession. 

In order to avoid deep discharge of the  battery and, as the consequence, reduction of 

its life cycle, it is necessary to disconnect the battery (press the button one more time). If it is 

necessary  to  continue  the  operation,  the  power  should  be  provided  to  the  terminals  as  per 

Paragraph 2.2.3. 

In  order  to  charge  the  battery,  it  is  necessary  to  connect  the  standard  +5V  network 

adapter with the permissible current load no less than 500 мА. 

After the charging is completed, the CHG will turn off. 

2.2.3.  It  is  possible  to  feed  the  converter  from  an  external  source  of  8…30  V.  The 

external source must be connected to the terminals “ + ” and ” – “. 

2.2.4. For connecting the control panel to the detector with the help of wire connection 

it is necessary to do the following: 

- Connect the FMC – RS cable (it is applied in a set) to the RS converter’s terminals 

“a-b” (a red wire – a, black – b); 

- Connect the plug of the FMC – RS cable to the detector’s RS-485 socket; 

- Connect the micro USB – USB cable to the socket of the USB converter RS-USB;  

- Connect the opposite cable plug to the PC’s USB port or to the Android device; 

- Wait till the drive activates (working with “Windows”);  

- Activate the application.  

 

                        3.  The manufacturer’s guarantee certificate  

 

 The 

manufacturer 

guarantees 

the 

conformity 

of 

the 

converter                                         

RS-BL     No  ______________  to  the conditions,  provided  in this  manual and  is  considered 

suitable for operation.  

                              Date of issue ______________   201                           

 

The guarantee operation period is 12 months as of the date of dispatch by the 
manufacturer. 

Summary of Contents for RS-BL

Page 1: ...JSC FORTEZA FORTEZA RS BL Please visit our internet sites www forteza com or www forteza eu Page 1 Converter RS BL Manual 2016 ...

Page 2: ...roperability with the FMC series detectors devices and Tribo M detector over the wire communication line only A personal computer PC or an Android based device may be used as the control panel 1 1 2 The converter consists of two independent converters Converter RS 485 in a USB hereinafter referred to as RS ensuring the connection of the detector to the PC or Android device over the wire communicat...

Page 3: ...cal characteristics of the BL are stated in Table 1 2 Table 1 2 The technical characteristics of the BL No Characteristic Meaning 1 Power supply voltage 3 6 internal accumulator 8 30 V external source 2 Consumption current no more than 80 mА 3 Battery capacity no less than 850 mA per hour 4 The time of operation of the transformer from fully charged battery no less than 8 hrs 5 Battery charge time...

Page 4: ...kage 1 Technical certificate 1 1 4 Installation and operation 1 4 1 The converter s operation principle The RS converter converts the electrical and time based characteristics of the RS 485 interface into the signals of the universal consecutive bus of the USB The BL converter transforms the electrical and time based characteristics of the RS 485 interface into signals of the Bluetooth wireless pe...

Page 5: ...FORTEZA JSC FORTEZA RS BL Please visit our internet sites www forteza com or www forteza eu Page 5 ...

Page 6: ...n to Bluetooth The proper power supply to BL is indicated by periodic synchronous flashings of both indicators in case of absence of exchange along the respective lines During the battery s discharge the RS and BL indicators are lighted in succession 2 1 5 The CHG light indicator of the charging device the red indicator reflects the state of the battery during the charging if the light is constant...

Page 7: ...l source of 8 30 V The external source must be connected to the terminals and 2 2 4 For connecting the control panel to the detector with the help of wire connection it is necessary to do the following Connect the FMC RS cable it is applied in a set to the RS converter s terminals a b a red wire a black b Connect the plug of the FMC RS cable to the detector s RS 485 socket Connect the micro USB US...

Page 8: ... the converter if The product is mechanically or thermally damaged or filled with water The failures caused by operational parameters set out in this manual failure to comply Send complaints to the following address JSC Forteza Tilzes str 38 91112 Klaipeda Lithuania Tel 370 46 411353 Fax 370 46 412231 E mail forteza forteza com ...

Reviews: