1.2. Technical characteristics 

1.2.1. The technical characteristics of the RS are provided in Table 1.1. 

Table 1.1 – The technical characteristics of the RS.

 

No. 

Characteristic  

Meaning 

Power supply voltage  

5 V (USB-port) 

Consumption current, no less than 

150 mА 

Maximum data transmission speed  

57600 bit/s 

USB interface specification  

2.0 

Compatibility with the operation system 

Windows XP… Windows 10 

Network topology RS-485 

Point-to-point 

Communication line length RS-485, no longer than 

1000 m 

Operating temperature range  

From - 40 to + 50

С 

 

1.2.2   The technical characteristics of the BL are stated in Table 1.2 

Table 1.2 – The technical characteristics of the BL  

No. 

Characteristic 

Meaning 

Power supply voltage  

3.6 (internal accumulator) 

8…30 V (external source) 

Consumption current, no more than 

80 mА 

Battery capacity, no less than  

850 mA per hour 

The time of operation of the transformer from fully 

charged battery, no less than  

8 hrs 

Battery charge time, no more than  

3 hrs 

Data transmission speed 

57600 bit/s 

Network topology RS-485 

Point-to-point 

The length of the communication line RS-485, no 

more than 

1000 m 

Bluetooth interface specification  

2.1 + EDR 

 

10 

   Bluetooth receiver sensitivity 

-92 dBm 

11 

Bluetooth transmitter capacity 

19 dBm (Class 1) 

12 

Bluetooth operating distance, no less than  

100 m 

13 

Operating temperature range  

From -20 to +50

С 

14 

Temperature range when the battery is charging  

From 0 to +45

С 

Summary of Contents for RS-BL

Page 1: ...JSC FORTEZA FORTEZA RS BL Please visit our internet sites www forteza com or www forteza eu Page 1 Converter RS BL Manual 2016 ...

Page 2: ...roperability with the FMC series detectors devices and Tribo M detector over the wire communication line only A personal computer PC or an Android based device may be used as the control panel 1 1 2 The converter consists of two independent converters Converter RS 485 in a USB hereinafter referred to as RS ensuring the connection of the detector to the PC or Android device over the wire communicat...

Page 3: ...cal characteristics of the BL are stated in Table 1 2 Table 1 2 The technical characteristics of the BL No Characteristic Meaning 1 Power supply voltage 3 6 internal accumulator 8 30 V external source 2 Consumption current no more than 80 mА 3 Battery capacity no less than 850 mA per hour 4 The time of operation of the transformer from fully charged battery no less than 8 hrs 5 Battery charge time...

Page 4: ...kage 1 Technical certificate 1 1 4 Installation and operation 1 4 1 The converter s operation principle The RS converter converts the electrical and time based characteristics of the RS 485 interface into the signals of the universal consecutive bus of the USB The BL converter transforms the electrical and time based characteristics of the RS 485 interface into signals of the Bluetooth wireless pe...

Page 5: ...FORTEZA JSC FORTEZA RS BL Please visit our internet sites www forteza com or www forteza eu Page 5 ...

Page 6: ...n to Bluetooth The proper power supply to BL is indicated by periodic synchronous flashings of both indicators in case of absence of exchange along the respective lines During the battery s discharge the RS and BL indicators are lighted in succession 2 1 5 The CHG light indicator of the charging device the red indicator reflects the state of the battery during the charging if the light is constant...

Page 7: ...l source of 8 30 V The external source must be connected to the terminals and 2 2 4 For connecting the control panel to the detector with the help of wire connection it is necessary to do the following Connect the FMC RS cable it is applied in a set to the RS converter s terminals a b a red wire a black b Connect the plug of the FMC RS cable to the detector s RS 485 socket Connect the micro USB US...

Page 8: ... the converter if The product is mechanically or thermally damaged or filled with water The failures caused by operational parameters set out in this manual failure to comply Send complaints to the following address JSC Forteza Tilzes str 38 91112 Klaipeda Lithuania Tel 370 46 411353 Fax 370 46 412231 E mail forteza forteza com ...

Reviews: