Forterra Bio Clean ARS Installation Manual Download Page 11

INSTRUCTIONS

11

Loosen the lateral screw with an Allen Key and 
adjust tension

Tighten the tension by moving the screw to the left

Secure the screw into place once adjustment is 
complete

1.

3.

4.

Step 5 - Adjusting the Bio Clean ARS Tension

Loosen the tension by moving the screw to the 

With the Allen Key still attached to the screw, move the screw to the 
right to have the tension loosened to your liking.  The tension depends 
on the county, project drawings, or engineer recommendations.

With the Allen Key still attached to the screw, move teh screw to 
the left to have the tension tightened to your liking. 

Once adjustment is complete, tighten the screw using an Allen Key.

Locate the screw attached to the side plate with a slot that is 
attached to the mounting block, and loosen it using an Allen Key. 

2.

Summary of Contents for Bio Clean ARS

Page 1: ...BIO CLEAN ARS Installation Manual English Play Setup Video ...

Page 2: ...e structure retrofit applications or surrounding infrastructure that may need to be repaired to allow for proper installation of the ARS shall be considered incidental and to be paid for at no cost to the client Bio Clean does offer installation services in certain areas Please contact Bio Clean for more information on pre authorized 3rd party contractors that can provide install service in your a...

Page 3: ...e mainframe of your entire assembly Center Hydra ARS Assembly x1 Left Hydra ARS Assembly x1 Right Hydra ARS Assembly x1 Cable Slide Member x1 Center Connector Plate x1 Aperture Connection Spring x1 Hinged Adjustable End Mount x1 Hydra Blade Amount Varies Tension Regulators Optional x1 Right End Plate x1 Left End Plate x1 Mounting Block x1 ...

Page 4: ...our Bio Clan ARS These are crucial components that will be the mainframe of your entire assembly 3 8 x 2 3 4 Anchors x1 1 4 x 20 Bolt Washer x1 125 x 20 Bolt x1 Tamper Proof Screws Depends on the county Quick Release Pin x1 Pivot Rod Support x1 Pressure Mount x1 Spring Stud x1 ...

Page 5: ...r this installation Caulking Gun x1 9 16 Wrench x1 Hand Level x1 Safety Glasses x1 Square Straight Edge x1 Impact Drill with Socket x1 Sharpie x1 Tape Measure x1 Roto Hammer x1 Sledge Hammer x1 Working Gloves x1 1 8 and 1 4 Allen Key x1 Grinder With Cutting Disk x1 ...

Page 6: ... end mount will attach to the curb of the basin for easy installation with specific hardware included Ensure that the tools mentioned in the The aperture connection spring adjusts the gaps and tensions of the hydrablades depending on your preference The cable slide member adjusts the hydrablades so that they can be attached or detached on the center connector plate The Bio Clean Blades are patent ...

Page 7: ...using a roto hammer drill Place the Left Bio Clean ARS unit back into position and secure teh bolt into the hole using an impact wrench with a 9 16 socket Place the Left Bio Clean ARS into the left most section of the basin as shown The left angle can be adjusted depending on the corner of the basin Some basins may have straight corner edges or some may have curved edges Adjust the left side hinge...

Page 8: ...nt installation methods from the previous step and if your unit came with multiple panels simply repeat these steps and attach them all as needed 1 3 4 Step 2 Installing the Center Bio Clean ARS Secure the connection plate with the hardware provided Depending on the county you are located in you may need to install temper proof screws Please check your project drawings to verify the hardware neede...

Page 9: ...anchor bolt and proceed to drill into the marked area using a marker then drill the hole using a roto hammer drill Place the Right Bio Clean ARS unit back into position and secure the bolt into the hole using an impact wrench with a 9 16 socket Begin Step Three by locating the Right Bio Clean ARS and attach the adjustable hinge to fit accordingly to the right corner of the basin and push into plac...

Page 10: ...t Simply pull the quick release pin out so you can detach the excess hydrablades Wiggle the center plate back and forth until it becomes loose enough to be easily removed Set the center plate aside once it becomes loose enough Using a grinder with a cutting disk cut the measured length of the tension spring and remove the excess hydrablades from the unit until the amount measured is properly remov...

Page 11: ...Allen Key still attached to the screw move the screw to the righttohavethetensionloosenedtoyourliking Thetensiondepends on the county project drawings or engineer recommendations With the Allen Key still attached to the screw move teh screw to the left to have the tension tightened to your liking Once adjustment is complete tighten the screw using an Allen Key Locate the screw attached to the side...

Page 12: ...Technical support 855 566 3938 stormwater forterrabp com Bio Clean Corporate Office 5796 Armada Drive Suite 250 Carlsbad CA 92008 https biocleanenvironmental com BioClean 2020 All Rights Reserved ...

Reviews: