Starting Up the Automatic Feeder
The thermostat for minimum operating temperature is activated as soon as the water tempe-
rature in the boiler falls below the preset temperature.
The minimum operating temperature has always to be 3
E
C below the boiler heating tempe-
rature, in order to avoid overlapping in the adjustment range.
The marks are intended to help the operator setting the temperature. Nevertheless, he has to
check the set values on his own authority.
For cold--soluble milk powders, a temperature of approx. 38
E
C will be sufficient.
For those milk powders containing fats with higher melting point, the outlet temperature has
to be between 42
E
C and 43
E
C.
4.5 Avoiding Measurement Errors
The temperature has always to be set very carefully!
Too low temperatures may cause digestive troubles due to undissolved fats.
Too high temperatures may cause inflammation of the mucosa in the abomasum that on its
part may lead to flatulences.
4.6 Measuring the Temperature
Turn the program switch to
1
.
Wait until the yellow pilot lamp for heating goes out.
Turn the program switch to
3
.
Wait until the water dispense is interrupted by the pressure switch.
Immediately afterwards measure the temperature by means of a precise
thermometer.
Measure the temperature carefully and, if necessary, adjust the thermo-
stats until the desired temperature is reached.