Programmes
Load
(kg)
Energy
con‐
sump‐
tion
(kWh)
Water
con‐
sump‐
tion (li‐
tre)
Approxi‐
mate
pro‐
gramme
duration
(mi‐
nutes)
Remain‐
ing
mois‐
ture
(%)
1)
Cottons 60°C
8
1,40
70
210
53
Cottons 40°C
8
1,20
69
205
53
Synthetics 40°C
3
0,60
56
140
35
Delicates 40°C
3
0,55
59
95
35
Wool/Silk 30°C
1,5
0,45
62
75
30
Standard cotton programmes
Standard 60°C cotton
8
0,81
52
275
53
Standard 60°C cotton
4
0,57
40
228
53
Standard 40°C cotton
4
0,51
40
226
53
1) At the end of spin phase.
Off Mode (W)
Left On Mode (W)
0.30
0.30
The information given in the chart above is compliant with the EU Commission regulation
1015/2010 implementing directive 2009/125/EC
TECHNICAL DATA
Dimension
Width/ Height/ Depth/ To‐
tal depth
600 mm/ 850 mm/ 571 mm/ 600 mm
Electrical connection
Voltage
Overall power
Fuse
Frequency
230 V
2200 W
10 A
50 Hz
Level of protection against ingress of solid particles
and moisture ensured by the protective cover, except
where the low voltage equipment has no protection
against moisture
IPX4
Water supply pressure
Minimum
Maximum
0,5 bar (0,05 MPa)
8 bar (0,8 MPa)
31