1
Sides
↔ wall
Mind. 30cm
Door opening angle
Mind. 132°
SPACE REQUIREMENT INCL. MINIMUM DISTANCES FOR PROPER VENTILATION:
A 1= Depth / B 1 = Width / C 1 = Depth (when the doors are open) /
D 1 = Space requirement of the doors
A1
B1
C1
D1
Mind. 620mm
Mind. 870mm
Mind. 1038mm
Mind. 300mm
Door opening angle: mind. 132°
These minimum distances may be less, but to do so can increase the power consumption of
the appliance.
Leveling
>Use the adjustable supporting feet for proper leveling and for proper air circulation in the lower
sectors of the appliance. Adjust the supporting feet / foot using a suitable spanner.
The figure above is an example only. Modifications are possible
>You can adjust an inclination of 0.5 ° to allow the doors to close by themselves.
>If you have to move the appliance, set the adjustable feet to minimum position so the appliance
can be moved on its rollers (depending on model) easily. Re-adjust the appliance when
transport has been completed.
NOTICE!
The rollers are no castors and intended to move the appliance forward and
backwards only. Lateral movements can damage your floor and the rollers.