background image

4

WWW.FORNEYIND.COM

General Operations

1. The sensitivity control is designed to make the filter lens more responsive to different light levels.  

Use toggle switch to adjust as required for application.

2. The delay control is used to adjust the hold time of the filter lens after welding is completed. Use 

toggle switch to adjust as required for application.

3. Variable Shade Control - The shade number can be set from 9 to 13 by turning the shade control 

knob until the arrow points to the desired shade number and/or toggle switch.

 

Care and Maintenance

•  Keep the sensors and solar cells clean. Clean the filter cartridge using a soapy water solution and 

soft cloth which should be damp but not saturated.

•  Do not use solvents or abrasive cleaning detergent.

•  Replace parts with only genuine Forney

®

 replacement parts.  

•  Do not immerse the filter in water. 

 

WARRANTY INFORMATION: Reference www.forneyind.com/support/warranty-information

TROUBLE SHOOTING

PROBLEM

POSSIBLE CAUSE

SOLUTION

Auto-darkening filter lens flickers and/or 

does not darken

Sensors are blocked

Clean the sensors with a soft cloth

Front cover lens is dirty

Clean cover lens with a soft cloth. Replace if necessary

Sensitivity is set too low

Adjust the sensitivity switch/knob. 

Auto-darkening filter lens will not turn ON Batteries are low or dead

Try replacing both batteries with new batteries, then 

check the low battery indicator

Auto-darkening filter lens turns dark 

when others are welding nearby

Sensitivity is set to high

Reduce sensitivity

Irregular darkening or dimming

Headband has been set unevenly on 

both sides of helmet (unequal distances 

from the eyes to filter's lens)

Reset headband to reduce difference in distances to 

filter, if necessary

WARNING: The welding helmet should be adjusted to ensure it is positioned over the eyes and 

face to ensure adequate protection

TECHNICAL SPECIFICATIONS

Viewing Area

5.97 Sq in.  

Variable Shade Selection

DIN 9 to 13

Shade Selector

External shade selector knob

Grind Mode

None

Number of Arc Sensors

2

Optical Clarity Rating

1/1/1/2

Shell

Lightweight (16.57 oz), impact resistant, fireproof

Sensitivity Control Adjustment

Low-High, Internal, adjust by switch button

Delay Control Adjustment

Low-High, Internal, adjust by switch button

Switching Speed

1/25,000 per second

Low TIG amps rated

5 AMP

Power Supply

Solar cells with 2-each non-replaceable 3V lithium batteries and automatic on/off technology

Meets Standards

All related CE standards (DIN and ISO), and ANSI Z87.1 safety standards

Summary of Contents for Easy Weld series

Page 1: ...EASY WELD SERIES AUTO DARKENING WELDING HELMET USER GUIDE OWNER S MANUAL WWW FORNEYIND COM ENGLISH ...

Page 2: ......

Page 3: ...ucture of the helmet and or auto darkening filter Before First Use Inspect the welding helmet for the following 1 The front and inside cover lenses are secure under all the tabs 2 Damage to the inner and outer cover lenses e g cracks scratches pitted welding spatter 3 Test your shade cartridge prior to welding by directing the front of the cartridge toward a bright source of light Then using your ...

Page 4: ...loth Replace if necessary Sensitivity is set too low Adjust the sensitivity switch knob Auto darkening filter lens will not turn ON Batteries are low or dead Try replacing both batteries with new batteries then check the low battery indicator Auto darkening filter lens turns dark when others are welding nearby Sensitivity is set to high Reduce sensitivity Irregular darkening or dimming Headband ha...

Page 5: ...5 WWW FORNEYIND COM FRANÇAIS EASY WELD SERIES GUIDE D UTILISATION POUR LES CASQUES AUTO OBSCURCISSANTS GUIDE DU PROPRIÉTAIRE ...

Page 6: ...e repérer les éléments suivants 1 Les couvre lentilles avant et intérieur sont bien en place sous toutes les languettes 2 Dommages sur les couvre lentilles intérieur et extérieur p ex fissures éraflures piqûres ou projection de soudage 3 Testez votre cartouche teintée avant de souder en dirigeant l avant vers une source lumineuse intense Ensuite couvrez et découvrez rapidement tous les capteurs av...

Page 7: ... Remplacez le au besoin Le réglage de la sensibilité est trop faible Réglez l interrupteur le bouton de sensibilité La lentille filtrante auto obscurcissante ne se met pas en marche Les batteries sont faibles ou épuisées Essayez de remplacer les deux batteries par des batteries neuves puis vérifiez l indicateur de batterie faible La lentille filtrante auto obscurcissante s assombrit lorsque d autr...

Page 8: ...8 WWW FORNEYIND COM MANUAL DEL PROPIETARIO ESPAÑOL EASY WELD SERIES GUÍA DEL USUARIO PARA CASCO FOTOSENSIBLE ...

Page 9: ...ontal e interior están colocadas firmemente en todas las pestañas 2 Daño en las lentes de la cubierta interior y exterior p ej grietas rayones roturas salpicaduras de soldadura 3 Pruebe el cartucho de sombra antes de soldar dirigiendo la parte frontal del cartucho hacia una fuente de luz brillante A continuación cubra y descubra los sensores rápidamente con los dedos El cartucho se oscurecerá mome...

Page 10: ...stán bloqueados Limpie los sensores con un paño suave La lente de la cubierta frontal está sucia Limpie la lente de la cubierta frontal con un paño suave Reemplace la lente de ser necesario La sensibilidad tiene un ajuste demasiado bajo Regule el interruptor perilla de sensibilidad Las lentes con filtro fotosensible no se activan Las baterías están bajas o agotadas Trate de reemplazar las baterías...

Page 11: ...__________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ _________________________________________...

Page 12: ...Forney Industries Inc 2057 Vermont Drive Fort Collins CO 80525 800 521 6038 www forneyind com ...

Reviews: