1.

 

L1, L2, L3 show phase A, phase B, phase C in lord.   

2.

 

L1, L2, L3 show phase A, phase B, phase C are electric.   

Display function 

Cycle display status, the default is 5 seconds. The display items as following: 
The display item can be settled: 
 
Display item 
Total power (A+B+C) 
Phase A power 
Phase B power 
Phase C power 
Serial number 
Software version 

SO Output 

0.0025 kWh/imp (Default) 
0.0025 kWh/imp, 0.01kWh/imp, 0.1kWh/imp, 1kWh/imp, 5kWh/imp, 10kWh/imp (Optional) 

1.7 Technical support 

Please contact 

TEL: 

021-60975591 

FAX: 

021-60975593 

Email: 

[email protected] 

www.china-metes.com                   

 
 
 
 

 

Summary of Contents for DRT-341D

Page 1: ...eters com Email sale01 china meters com 86 21 62270763 62270963 DRT 341D Three phase four wires DIN rail energy meter LCD display One module 1 1 Foreword 1 2 General Technical Data 1 3 Basic errors 1 4 Dimension 1 5 Wiring diagram 1 6 Operating 1 7 Technical support User manual ...

Page 2: ...ere might be possibilities that our product shows a fault or failure for which we do apologize Under normal conditions your product should give you years of benefit and pleasure In case there is a problem with the energy meter you should contact your dealer immediately All energy meters are sealed with a special seal Once this seal is broken there is no possibility to claim for warranty Therefore ...

Page 3: ...1 2 12 Voltage withstand AC voltage withstand 2KV for 1 minute Impulse voltage withstand 6KV 1 2uS waveform 1 2 13 Current withstand 30Imax for 0 01s 1 2 14 Pulse output rate 400imp kWh 1 2 15 Data stored More than 20 years when power off To comply with the protection requirements the meter must be mounted in a class IP 51 enclosure or better according to IEC 60529 1 3 Basic errors 0 05Ib Cosφ 1 1...

Page 4: ...O LTD www china meters com Email sale01 china meters com 86 21 62270763 62270963 B C A D A Front panel B Cover C Base D Security hasp Material Front panel PC inflammable retarding Cover ABS inflammable retarding Base ABS inflammable retarding 1 5 wiring diagram ...

Page 5: ...g consumption and can t be reset to zero The reading accuracy is 1 100 kWh Record The DRT 341D series energy meter can separate records the total power phase A phase B phase C subentry power The total power phase A power phase B power phase C power Pulse output The DRT_341D Series DIN rail energy meter is equipped with a pulse output which is fully separated from the inside circuit That generates ...

Page 6: ...function Cycle display status the default is 5 seconds The display items as following The display item can be settled Display item Total power A B C Phase A power Phase B power Phase C power Serial number Software version SO Output 0 0025 kWh imp Default 0 0025 kWh imp 0 01kWh imp 0 1kWh imp 1kWh imp 5kWh imp 10kWh imp Optional 1 7 Technical support Please contact TEL 021 60975591 FAX 021 60975593...