forlong DRT-341D User Manual Download Page 2

                                                        

DRS-341 series User Manual

 

                                                                                                                                                                                                                                                 
 
Shanghai Fengyilong Electronic CO.LTD                           

www.china-meters.com

                            Email:[email protected]

 

                                                                                                                                                                                86-21-62270763/ 62270963 

1.1 Foreword

 

Thank you for purchasing the FORLONG DRT- 341D series DIN rail three phase four wire energy meters. 
With the FORLONG product range we have provided a large scale of energy meters on the market suitable 
for  110V  AC  to  400V  AC  (50  or  60Hz).  Besides  the  normal  energy  meters  we  also  developed  our  own 
pre-paid meters with chip card, chip card re-loaders and a complete PC management control system. For 
more information on other products please contact our sales department at [email protected] 
 
Although we produce the Forlong DRT- 341Dseries meter according to IEC 62053-21 and our strict quality 
inspection, there might be possibilities that our product shows a fault or failure for which we do apologize.   
Under  normal  conditions  your  product  should  give  you  years  of  benefit  and  pleasure.  In  case  there  is  a 
problem with the energy meter you should contact your dealer immediately. All energy meters are sealed with 
a special seal. Once this seal is broken there is no possibility to claim for warranty. Therefore NEVER open 
meter by yourself or break the seal of the energy meter. The warranty time is 6 moths after installation, and 
only valid for construction faults. 

1.2General Technical Data 

1.2.1 Voltage (V)           

Voltage AC (Un)                                        230/400(3~) 
Voltage rang                                              161/279 to 300/500(3~) 

1.2.2 Current (A) 
        Base (Ib)                                                    10 
        Max (Imax)                                                100 

Starting current (mA)                              0.4% of Ib 

1.2.3 Power consumption of current            ≤2W /10VA per phase 
1.2.4 General data                                                       

  Frequency(Hz)                                        50(±10%) 
  Accuracy                                                  1.0 

1.2.5Standards                                                  IEC 62053-21 
1.2.6 Memory back-up                                      EEPROM   
1.2.7 Enclosure material                                       
    Upper                                                              Polycarbonate 
    Lower                                                              Polycarbonate/glass fibre 
 

Summary of Contents for DRT-341D

Page 1: ...eters com Email sale01 china meters com 86 21 62270763 62270963 DRT 341D Three phase four wires DIN rail energy meter LCD display One module 1 1 Foreword 1 2 General Technical Data 1 3 Basic errors 1 4 Dimension 1 5 Wiring diagram 1 6 Operating 1 7 Technical support User manual ...

Page 2: ...ere might be possibilities that our product shows a fault or failure for which we do apologize Under normal conditions your product should give you years of benefit and pleasure In case there is a problem with the energy meter you should contact your dealer immediately All energy meters are sealed with a special seal Once this seal is broken there is no possibility to claim for warranty Therefore ...

Page 3: ...1 2 12 Voltage withstand AC voltage withstand 2KV for 1 minute Impulse voltage withstand 6KV 1 2uS waveform 1 2 13 Current withstand 30Imax for 0 01s 1 2 14 Pulse output rate 400imp kWh 1 2 15 Data stored More than 20 years when power off To comply with the protection requirements the meter must be mounted in a class IP 51 enclosure or better according to IEC 60529 1 3 Basic errors 0 05Ib Cosφ 1 1...

Page 4: ...O LTD www china meters com Email sale01 china meters com 86 21 62270763 62270963 B C A D A Front panel B Cover C Base D Security hasp Material Front panel PC inflammable retarding Cover ABS inflammable retarding Base ABS inflammable retarding 1 5 wiring diagram ...

Page 5: ...g consumption and can t be reset to zero The reading accuracy is 1 100 kWh Record The DRT 341D series energy meter can separate records the total power phase A phase B phase C subentry power The total power phase A power phase B power phase C power Pulse output The DRT_341D Series DIN rail energy meter is equipped with a pulse output which is fully separated from the inside circuit That generates ...

Page 6: ...function Cycle display status the default is 5 seconds The display items as following The display item can be settled Display item Total power A B C Phase A power Phase B power Phase C power Serial number Software version SO Output 0 0025 kWh imp Default 0 0025 kWh imp 0 01kWh imp 0 1kWh imp 1kWh imp 5kWh imp 10kWh imp Optional 1 7 Technical support Please contact TEL 021 60975591 FAX 021 60975593...