INSTALLATION/ OPERATION

IMPORTANT! PLEASE READ BEFORE INSTALLATION

• 

If the unit has recently been transported please let unit stand still for a minimum of 24 hours before plugging it in.

• 

Make sure that the unit drops down to desired temperature before loading the unit with product.

• 

Make sure that there is proper ventilation around the unit in the area where it will operate.

• 

Make sure all accessories are installed (i.e. shelves, shelf clips, casters) before plugging the unit in.

• 

Please read through the manual in its entirety. 

CABINET LOCATION GUIDELINES

• 

Install the unit on strong and leveled surfaces

- unit may make unpleasant noises if surface is uneven
- unit may malfunction if surface is uneven

• 

Install the unit in an indoor, well-ventilated area

- unit performs more efficiently in a well-ventilated area
- for best performance, please maintain clearance of 100 mm on the back of the unit
- outdoor use may cause decreased efficiency and damage to the unit

• 

Avoid installation in a high humidity and/or dusty area

- humidity could cause unit to rust and decrease efficiency of the unit
- dust collected on condenser coil will cause unit to malfunction. Clean the condenser at least once a month with a brush 
or clean cloth
- malfunction due to dirty condenser will void warranty

• 

Select a location away from heat and moisture-generating equipment

- high ambient temperatures will cause the compressor to overwork, leading to higher energy bills and gradual breakdown 
of the unit
- malfunction due to high ambient temperature will void warranty

More than 100 mm

Figure 2.

Figure 1.

Please dispose of all waste packaging appropriately and in accordance with all local recycling 

laws.

Summary of Contents for FG07035

Page 1: ...USER S MANUAL Modele Models FG07035 FG07135 FG08035 FG08135 FG07060 FG07160 FG08060 FG08160 Przed rozpocz ciem wprowadzania nastaw urz dzenia jego obs ug i konserwacj dok adnie zapozna si z niniejsz i...

Page 2: ...mieszczeniu urz dzenie dzia a sprawnie w dobrze wentylowanych pomieszczeniach w celu zapewnienia jak najlepszej wydajno ci nale y pozostawi 100 mm odst p od tylnej cz ci urz dzenia u ytkowanie urz dze...

Page 3: ...e na swoich miejscach Wa ne jest aby p ki zosta y dok adnie wyr wnane przed rozpocz ciem umieszczania na nich produkt w W celu zapewnienia poprawnego przep ywu powietrza wewn trz urz dzenia nale y upe...

Page 4: ...dzenie od sieci zasilaj cej WYMAGA SI ODPOWIEDNIEGO UZIEMIENIA W celu ograniczenia ryzyka pora enia pr dem i po aru nale y upewni si e urz dzenie jest prawid owo uziemione ZAKAZ Nie wolno podejmowa pr...

Page 5: ...regularnie my uszczelki drzwiowe zaleca si mycie raz w tygodniu Po prostu nale y wyj uszczelk z ramy drzwi zanurzy w ciep ej wodzie z myd em na 30 minut osuszy mi kk szmatk i ponownie zamontowa Sprawd...

Page 6: ...s poprawnie u o one Wyj uszczelk i umy w ciep ej wodzie z myd em Sprawdzi stan uszczelki i wymieni w razie konieczno ci Wyczy ci cewk skraplacza Od czy urz dzenie i odczeka a cewka si rozmrozi Upewni...

Page 7: ...ventilated area unit performs more efficiently in a well ventilated area for best performance please maintain clearance of 100 mm on the back of the unit outdoor use may cause decreased efficiency an...

Page 8: ...f clips are completely fastened in their correct locations It is important that all shelves rest completely level before stocking your cabinet with product In order to maintain correct air flow inside...

Page 9: ...R GROUNDING REQUIRED To minimize shock and fire hazards make sure that the unit is properly grounded PROHIBITION Nie wolno podejmowa pr b usuwania lub naprawiania komponent w chyba e stosowne instrukc...

Page 10: ...gaskets on a regular basis preferably weekly Simply remove door gasket from the frame of the door soak in warm water and soap for thirty 30 minutes dry with soft cloth and replace Check door gaskets...

Page 11: ...e Ensure gaskets are snapped in completely Remove gasket and wash with soap and water Check condition of gasket and replace if necessary Clean the condenser coil Unplug unit and allow coil to defrost...

Page 12: ...Sprawd wi cej produkt w na Check out more products on www forgast pl Kontakt Contact 48 327 508 130 info forgast pl...

Page 13: ...j cy traci uprawnienia z tytu u gwarancji w zakresie wady okre lonej w ust 2 OWU Przedmiotowe postanowienie nie ma zastosowania do um w zawieranych z kupuj cymi konsumentami 4 Gwarant ponosi odpowiedz...

Page 14: ...ntaktowania z kupuj cym w terminie 7 dni roboczych od dnia otrzymania prawid owego zg oszenia okre lonego w ust 8 OWG 10 W razie stwierdzenia zasadno ci zg oszenia gwarancyjnego Gwarant zobowi zuje si...

Page 15: ...ce z gwarancji wygasaj 21 Gwarant nie ponosi odpowiedzialno ci za straty oraz utrat mo liwo ci osi gania korzy ci przez kupuj cego powsta w wyniku wyst pienia wady w sprzedanym Produkcie 22 Do oceny...

Reviews: