6
│
Installing the Forest Shuttle
®
S / M / L
Z-Wave
Connecting to port 1 or port 2 of the
FOREST SHUTTLE® S / M / L
Z-Wave
do-it-yourself plug
pin8 pin1 pin8 pin1
(CLOSE) (OPEN) (CLOSE) (OPEN)
MANUAL SWITCH CONNECTED TO DRY CONTACT INPUTS
A manual switch or a relay output of a Home Automation System can easily be connected to the Shuttle S or L. Be sure the
switch/relay is potential free. Use pins 1, 3 and 8 of PORT1 or PORT2.
OPEN: when pin 1 is connected to pin 3 (COMMON) the Shuttle will open the curtain.
CLOSE: when pin 8 is connected to pin 3 (COMMON) the Shuttle will close the curtain.
STOP: when pin 1 and 8 are connected to pin 3 (COMMON) the Shuttle will stop moving the curtain.
Different modes can be set:
-
Pulse: when short contact is made the curtain will open or close fully (default setting)
-
Continuous: the curtain will move as long as the contact is made (mostly used for Home Automation Systems)
-
Single button switch (doorbell principle)
: either one of the four inputs will act as following: open → stop → close → stop
→ open → stop → close → stop etc.
To change this setting see page 4.