background image

Step 7 - Attaching Cover Strips

Step 8 - Roof Battens

Step 9 - Attach Roof Supports to Roof 1

Front/Side Cover Strip

Size: 40x12x1915mm

Back Corner Cover Strip

Size: 28x12x1839mm

Front/Side Cover Strip

Size: 40x12x1915mm

Back Corner Cover Strip

Size:

x12x1839mm

40

Front/Side Cover Strip

Size: 40x12x1915mm

Front/Side Cover Strip

Size: 40x12x1915mm

Roof Support (2)

Size: 28x28x896mm

Roof Support (1)

Size: 28x28x1195mm

Roof Support (1)

Size: 28x28x1195mm

Roof Support (1)

Size: 28x28x1195mm

Roof Support (3)

Size: 28x28x2010mm

Roof Support (4)

Size: 28x28x1114mm

Roof 2

Size: 2070x1143mm

Step 10 Attach Roof Supports to Roof 2

OVER

HANG

PLEASE NOTE

ORIENTATION

NOTCH

DETAIL E

E

D

DETAIL F

F

3x

30mm

Screws

3x

30mm

Screws

4x

30mm

Screws

MUST PRE DRILL

3x

30mm

Screws

NOTE

GAP

Roof 1 

Size: 2070x928mm

3x

30mm

Screws

3x

30mm

Screws

MUST PRE DRILL

4x

30mm

Screws

4x

30mm

Screws

4x

30mm

Screws

4x

30mm

Screws

4x

30mm

Screws

4x

30mm

Screws

Roof Batten

Size: 45x x1900mm

45

1x

30mm

Screws

1x

30mm

Screws

‘Z’

Bracket

‘Z’

Bracket

2x

30mm

Screws

2x

30mm

Screws

Repeat process for both battens.

491mm

MUST PRE DRILL

ATTACH COVER STRIPS 

TOWARDS THE BOTTOM TO 

ALLOW SPACE FOR THE 

ROOF.

MUST PRE DRILL

Summary of Contents for TPC77

Page 1: ...5 00 pm Monday to Friday Fixing Pack TPCS77FP w e r c S m m 0 6 7 y t Q w e r c S m m 0 5 7 4 y t Q w e r c S m m 25 1 8 y t Q w e r c S m m 0 3 00 1 y t Q Felt Tacks 60 Qty T Hinge Qty 6 Casement Sta...

Page 2: ...the sections and causing the roof doors and windows to misalign There is more information on base preparation on our website www forestgarden co uk TOOLS NEEDED We recommend using the following tools...

Page 3: ...t temperatures above 5 C In cold temperatures extra care must be taken when handling and installing to prevent cracking and damage to the felt The felt should not be rolled folded or used in temperatu...

Page 4: ...t 1 Size 28x28x1195mm Qty 3 28281195P Back Corner Batten Size 28x28x1829mm Qty 1 28281829P Front Side Cover Strip Size 40x12x1915mm Qty 4 40121915PPT Roof Batten Size 45x x1900mm 45 Qty 2 45 1900P 45...

Page 5: ...Left Back Panels Step 4 Attaching Window Panels DETAIL B B DETAIL A A FINAL OUTCOME MUST PRE DRILL Step 5 Attaching Angled Door Frame Battens Step 6 Attaching The Door Frame Outside Inside 50mm Screw...

Page 6: ...pport 3 Size 28x28x2010mm Roof Support 4 Size 28x28x1114mm Roof 2 Size 2070x1143mm Step 10 Attach Roof Supports to Roof 2 OVER HANG PLEASE NOTE ORIENTATION NOTCH DETAIL E E D DETAIL F F 3x 30mm Screws...

Page 7: ...INTO OVER HANG INTO TOP OF THE FRAME Side Roof Fascia Size 90x12x1200mm Side Roof Fascia Size 90x12x1200mm Front Roof Fascia Size 90x12x1265mm Door Stop Strip Size 28x12x928mm MUST PRE DRILL 1000 mm...

Page 8: ...h the batten into the door frame as shown Attach the block onto the opposite door of which you attached the slamming strip 4x 0 m m 3 Screws Door Size 456x1820mm k c o l B r o o D Size 97x150x20mm 3x...

Reviews: