background image

SCREW MUST GO

TROUGH FLOOR PANEL

AND INTO THE BATTENS

OF FLOOR PANEL

3x

50mm

Screws

4x

50mm

Screws

4x

50mm

Screws

Into

Floor

Into

Floor

Connect

Walls

OVER-

LAPPING

Left Back Panel

Size: 1900x1944mm

3x

50mm

Screws Connect

Walls

2x

50mm

Screws

Into

Floor

Window Panel

Size: 1100x1945mm

2x

50mm

Screws

Into

Floor

3x

50mm

Screws

Into

Floor

3x

50mm

Screws

Connect

Walls

3x

50mm

Screws

Connect

Walls

INSIDE VIEW

Window Panel

Size: 1100x1945mm

Window Panel

Size: 1100x1945mm

OVER-

LAPPING

E

DI

S

BAC

K

Step 3 - Attaching Right & Left Back Panels

Step 4 - Attaching Window Panels

DETAIL B

B

DETAIL A

A

FINAL OUTCOME

MUST PRE DRILL

Step 5 - Attaching Angled Door Frame Battens

Step 6 - Attaching The Door Frame

Outside

Inside

50mm

Screw

Into

Batten

4x

50mm

Screws

Into

Batten

Into

Frame

Into

Frame

3x

50mm

Screws

4x

50mm

Screws

Connect

Walls

2x

50mm

Screws

Into

Floor

3x

50mm

Screws

Connect

Walls

MUST PRE DRILL

MUST PRE DRILL

Angled Door Batten

Size: 32x32x1930mm

Door Frame

Size: 1170x1945mm

Angled Door Batten

Size: 32x32x1930mm

SCREW MUST GO TROUGH FLOOR PANEL

AND INTO THE BATTENS OF FLOOR PANEL

MUST PRE DRILL

Right Back Panel

Size: 1900x1944mm

Back Corner Batten

Size: 28x28x1829mm

Angled Door Batten

Size: 32x32x1930mm

Door Frame

Size: 1170x1945mm

Summary of Contents for TPC77

Page 1: ...5 00 pm Monday to Friday Fixing Pack TPCS77FP w e r c S m m 0 6 7 y t Q w e r c S m m 0 5 7 4 y t Q w e r c S m m 25 1 8 y t Q w e r c S m m 0 3 00 1 y t Q Felt Tacks 60 Qty T Hinge Qty 6 Casement Sta...

Page 2: ...the sections and causing the roof doors and windows to misalign There is more information on base preparation on our website www forestgarden co uk TOOLS NEEDED We recommend using the following tools...

Page 3: ...t temperatures above 5 C In cold temperatures extra care must be taken when handling and installing to prevent cracking and damage to the felt The felt should not be rolled folded or used in temperatu...

Page 4: ...t 1 Size 28x28x1195mm Qty 3 28281195P Back Corner Batten Size 28x28x1829mm Qty 1 28281829P Front Side Cover Strip Size 40x12x1915mm Qty 4 40121915PPT Roof Batten Size 45x x1900mm 45 Qty 2 45 1900P 45...

Page 5: ...Left Back Panels Step 4 Attaching Window Panels DETAIL B B DETAIL A A FINAL OUTCOME MUST PRE DRILL Step 5 Attaching Angled Door Frame Battens Step 6 Attaching The Door Frame Outside Inside 50mm Screw...

Page 6: ...pport 3 Size 28x28x2010mm Roof Support 4 Size 28x28x1114mm Roof 2 Size 2070x1143mm Step 10 Attach Roof Supports to Roof 2 OVER HANG PLEASE NOTE ORIENTATION NOTCH DETAIL E E D DETAIL F F 3x 30mm Screws...

Page 7: ...INTO OVER HANG INTO TOP OF THE FRAME Side Roof Fascia Size 90x12x1200mm Side Roof Fascia Size 90x12x1200mm Front Roof Fascia Size 90x12x1265mm Door Stop Strip Size 28x12x928mm MUST PRE DRILL 1000 mm...

Page 8: ...h the batten into the door frame as shown Attach the block onto the opposite door of which you attached the slamming strip 4x 0 m m 3 Screws Door Size 456x1820mm k c o l B r o o D Size 97x150x20mm 3x...

Reviews: