5.7. Time Set
The detector has a back-up battery, edit precise time to save. The detector will remain
in accurate operation after the power is turned off.
6. INSTALLATION GUIDE
6.1 Installation Location Considerations
Installing this industrial gas detector will depend on the application. For isolated rooms,
ensure the detector is located at head level to allow for visual inspection of the display
screen. Locate away from ducts and vents, air turbulence (i.e. doors that may dilute air
quality in the room) and in a location that represents the “general” target area air
quality. Some gas (depending if they are light of heavy) may be best mounted very high
on the ceiling or low closer to the ground. Email us for a recommendation.
•
Do not install in areas where the temperature is close to detector extreme
specifications for example in very cold or very hot environment 0-122F.
•
Do not install within 5 ft. of heating or cooking appliances.
•
Do not install near vents, flues, chimneys or air ventilation openings.
•
Do not install near ceiling fans, doors, windows or areas directly exposed to the
weather so external air, water or rain reaches the detector.
•
Do not install in dead air spaces, such as peaks of vaulted ceilings or gabled roofs,
where toxic air may not reach the sensor in time to provide early warning.
•
Do not install on a switched or dimmer-controlled outlet.
•
Do not obstruct the vents located on the alarm. Do not place the alarm where
drapes, furniture or other objects block the flow of air to the vents or limit the visual
and audible alarms.
6.2 Detector Installation
The detector is designed to be wall mounted. Depending on local code, conduit for
power wires / RELAY lines may be required, so please ensure a qualified electrical
technician undertakes the installation. The below figure shows a typical conduit
installation. Most installation are custom installations, hence please install detectors
using qualified technical personnel.