Ford FG6250P Manual Download Page 9

 

FG6250P(E) - FG7750P(E) - FG9250P(E) 

EN 

Copyright © 2016 

P a g e

 | 

9

 

www.fordpowerequipment.co.uk 

 

Tie back or wear protective head covering to contain long hair. 

WARNING! 

 

 Keep  engine  away  from  flammable  objects  and  other 

hazardous materials. 

 

The fuel and its vapors used to power this unit are highly flammable and could explode resulting 
in serious injury or death. 

 

Never fill or drain fuel tank indoors. 

 

Never overfill fuel tank. If fuel spills, move the unit at least 30 feet away from the spill and wipe 
up any remaining fuel on the unit before starting the engine. 

 

Never smoke while operating or fueling this unit. 

 

Never operate or store this unit near an open flame, heat, or any other ignition source. 

 

Generator should have at least 5 feet of clearance from buildings or other equipment during 
operation. 

 

Keep engine free of grass, leaves, or grease which are flammable. 

 

When adding or draining fuel, unit should be turned off for at least 2 minutes to cool before 
removing fuel cap.  

 

If unit has been running then the fuel cap is under pressure, remove slowly. 

 

To keep fuel from spilling, secure unit so it cannot tip while operating or transporting. 

 

When transporting unit, disconnect the spark plug wire and make sure the fuel tank is empty with 
the fuel shut-off valve turned to the off position. 

WARNING! Pull cord recoils rapidly and pulls arm towards engine faster than you 
can let go which could result in injury. 

 

To avoid recoil, pull starter cord slowly until resistance is felt, then pull rapidly. 

WARNING! 

Avoid contacting hot areas of this unit. 

 

Use caution around the muffler, cylinder, and other engine parts as they can be extremely hot. 

 

Allow hot components to cool before touching. 

WARNING! 

 This  generator  produces  a  very  high  voltage  which  could 

result in burns or electrocution causing serious injury or death. 

 

Never handle the generator, electronic devices, or any cord while standing in water, while 
barefoot, or when hands or feet are wet. 

 

Always keep the generator dry. Never operate generator in rain or under wet conditions. 

 

Never plug electronic devices into generator having frayed, worn, or bare wires. Never touch bare 
wires or make contact with receptacles. 

 

Never permit a child or unqualified person to operate generator. Keep children a minimum of 10 
feet away from the generator at all times. 

 

If using the generator for back up power, notify the utility company. 

 

If connecting generator to a building’s electrical system for standby power, you must use a 
qualified electrician to install a transfer switch. Failure to isolate the generator from the power 
utility could result in serious injury or death to electric utility workers. 

Summary of Contents for FG6250P

Page 1: ...FG6250P E FG7750P E FG9250P E EN Copyright 2016 P a g e 1 www fordpowerequipment co uk Fig A1...

Page 2: ...FG6250P E FG7750P E FG9250P E EN Copyright 2016 P a g e 2 www fordpowerequipment co uk Fig A2...

Page 3: ...s Fig 5 13 6 6 Recoil starting Fig 6 FG6250P FG7750P FG9250P 13 7 BEFORE STARTING 14 7 1 Adding Checking Engine Oil See Fig 7 15 7 2 Adding Fuel See Fig 8 15 7 3 Connecting Generator to an Electrical...

Page 4: ...RK ARRESTOR SEE FIG 22 23 24 COOLING SYSTEM 23 25 CARBURETOR ADJUSTMENT 23 26 REPLACING FUEL FILTER SEE FIG 23 24 27 DRAINING FUEL TANK AND CARBURETOR 24 27 1 Draining the fuel tank 24 27 2 Draining t...

Page 5: ...FG6250P E FG7750P E FG9250P E EN Copyright 2016 P a g e 5 www fordpowerequipment co uk 35 2 Maintenance Fout Bladwijzer niet gedefinieerd 36 SERVICE 30...

Page 6: ...hting or serve as a back up power source during power outages It is not designed for professional use WARNING Please read and understand this operating manual before use and keep it for your future re...

Page 7: ...t Guide 1 Spark Plug Wrench 1 Toolkit Phillips screwdriver 1 Combination Wrench 2 Funnel 1 Handles 2 Bushings Flanged 4 Outlets 3 Description Qty M8 x 50mm Hex Bolts for Handle 2 M8 Flanged Nuts for H...

Page 8: ...pen Install a battery operated carbon monoxide alarm near bedrooms Keep exhaust from this unit from entering a confined area through windows doors vents or other openings When working in areas where v...

Page 9: ...ank is empty with the fuel shut off valve turned to the off position WARNING Pull cord recoils rapidly and pulls arm towards engine faster than you can let go which could result in injury To avoid rec...

Page 10: ...t rated frequency and voltage WARNING Only use this unit as intended or serious injury or death could result Do not bypass any safety device Moving parts are covered with guards Make sure all protecti...

Page 11: ...es 2 hair pins 2 washers 2 hub caps and 2 self tapping screws Raise or tilt generator so you can slide the wheel axle pin into the wheel the washer the wheel mounting hole located on the side of the f...

Page 12: ...through the eyelet and tighten the screw and make sure the terminal will not touch any part of the frame Install the Red protection boot Fig 4 Repeat these steps for the Black Terminal WARNING Be car...

Page 13: ...6250P E FG7750P E FG9250P E EN Copyright 2016 P a g e 13 www fordpowerequipment co uk 6 5 Installing the handles Fig 5 Fig 5 6 6 Recoil starting Fig 6 Attach the Recoil Starter Grip to the bracket Fig...

Page 14: ...Wear Eye Protection Never Reverse Pole Connections Never turn the battery upside down DO NOT Smoke near the battery If electrolyte contacts the skin wash the area immediately with clean water If you...

Page 15: ...vide space for fuel expansion Fig 8 CAUTION You must add oil before first operating this generator Always check oil level before each operation DO NOT USE E15 OR E85 FUEL IN THIS UNIT IT IS A VIOLATIO...

Page 16: ...s Fig 9 WARNING Generator must be properly grounded to prevent electrocution Only operate generator on a level surface Always connect the nut and ground terminal on the frame to an appropriate ground...

Page 17: ...Pull cord recoils rapidly and pulls arm towards engine faster than you can let go which could result in injury To avoid recoil pull starter cord slowly until resistance is felt then pull rapidly fig 1...

Page 18: ...enerator must be carried fold handle to the down position Never lift or carry generator by its handle CAUTION This product is heavy and requires several people to lift Lift and lower with your legs by...

Page 19: ...oltage V displays the operating voltage of the generator Frequency F displays the frequency in hertz at which the generator is running The Run Maintenance Timer displays the time in hours and minutes...

Page 20: ...heat created by the generator to prevent icing 1 Cut off all flaps 2 Cut off one of the long sides of the carton to expose the units muffler and exhaust Do not enclose the muffler exhaust 3 side of t...

Page 21: ...lent Service Fuel Valve Inspect Muffler and Spark Arrester Check and Clean Air Cleaner Replace Air Filter Clean Cooling System 19CHANGING OIL SEE FIG 19 Run the Generator until the Engine is warm Plac...

Page 22: ...ity for the engine Use the chart to select the best viscosity for the outdoor temperature range expected Note Below 40 F 4 C the use of SAE 30 will result in hard starting Above 80 F 27 C the use of 1...

Page 23: ...nd slowly adjust to 0 700 mm 0 800 mm 028 031 if necessary Reinstall spark plug and tighten to Torque 22 0 26 9 Nm 16 20 ft lb Reconnect spark plug wire If spark plug is worn replace only with an equi...

Page 24: ...ior to fill up Fig 22 Fig 23 27DRAINING FUEL TANK AND CARBURETOR To help prevent gum deposits in the fuel system drain the fuel from the tank and carburetor before storing the unit for long periods of...

Page 25: ...ris if obstructed For short term storage start generator once every 7 days For semi long term storage add fuel stabilizer to prevent stale fuel from causing acid and gum deposits in the fuel system an...

Page 26: ...500W 6500W 7500W Voltage 110V 230 240V AC Engine 420cc OHV 4 Stroke Air Cooled Engine Oil 10W30 1L Fuel Tank 25L Unleaded Gasoline 31NOISE Noise values measured according to relevant standard K 3 FG62...

Page 27: ...cted from spark plug 6 Bad spark plug 7 Water in fuel 8 Fuel valve is in OFF position 9 Over choking 10 Low oil level 11 Rich fuel mixture 12 Intake valve stuck open or closed 13 Loss of engine compre...

Page 28: ...ment co uk 33ELECTRICAL DIAGRAM RECOIL STARTER TYPE Alternator Alternator control panel control panel Engine Engine Engine switch connecting Bl Black Br Brown Y G Yellow Green 0 Orange Br R Brown Red...

Page 29: ...ment co uk 34ELECTRICAL DIAGRAM ELECTRIC START TYPE Alternator Alternator control panel control panel Engine Engine Engine switch connecting Bl Black Br Brown Y G Yellow Green 0 Orange Br R Brown Red...

Page 30: ...CE How to contact us To order parts receive warranty assistance or other services inquiries you can contact us by Please see contact data on the back of this manual Record the following information be...