Ford FG6250P Manual Download Page 12

 

FG6250P(E) - FG7750P(E) - FG9250P(E) 

EN 

Copyright © 2016 

P a g e

 | 

12

 

www.fordpowerequipment.co.uk 

6.3

 

Installing Support Leg (See Fig.3) 

 

 

Parts needed - Support leg & M8 screw (2). 

 

Raise the front end of the generator high 
enough to gain access to the bottom of the 
frame. 

 

Securely position props underneath to 
support. 

 

Line up holes on the support leg bracket to 
the holes on the front of the generator 
frame. 

 

Attach the support leg using M8 screws (2). 

Installing the handles (See Fig.3) 

 

Fig.3 

6.4

 

Attaching the Battery Cable (See Fig.4)  

(FG6250PE / FG7750PE/ FG 9250PE ONLY)

 

 

Parts needed - Black and 
Red battery cable 

 

The Red (+) Connector 
should be attached to the 
battery first. 

 

Remove the screw from 
the battery terminal. 

 

Place the screw through 
the eyelet and tighten the 
screw and make sure the 
terminal will not touch any 
part of the frame. 

 

Install the Red protection 
boot. 

 

 

Fig.4 

Repeat these steps for the Black (-) Terminal. 

WARNING! Be careful not to short across the terminals when installing. Shorting 
the terminals together can cause sparks, damage to the battery or generator, or 
even burns or explosions. 

Cover the terminals with the rubber covers 
When removing the battery for replacement: Remove the nut and bolt first from the negative (Black) 
post,  then  from  the  positive  (Red)  post,  being  careful  not  to  short  across  the  terminals.  Always 
abide  by  the  safety  warnings  provided  with  the  battery.  Remove  the  battery  and  dispose  of  it 
according to your local and state regulations. 

WARNING!  Battery  posts,  terminals,  and  accessories  contain  lead  and  lead 
compounds known to cause | cancer and reproductive harm. 

 

Always wash hands after touching battery 

 

 

Summary of Contents for FG6250P

Page 1: ...FG6250P E FG7750P E FG9250P E EN Copyright 2016 P a g e 1 www fordpowerequipment co uk Fig A1...

Page 2: ...FG6250P E FG7750P E FG9250P E EN Copyright 2016 P a g e 2 www fordpowerequipment co uk Fig A2...

Page 3: ...s Fig 5 13 6 6 Recoil starting Fig 6 FG6250P FG7750P FG9250P 13 7 BEFORE STARTING 14 7 1 Adding Checking Engine Oil See Fig 7 15 7 2 Adding Fuel See Fig 8 15 7 3 Connecting Generator to an Electrical...

Page 4: ...RK ARRESTOR SEE FIG 22 23 24 COOLING SYSTEM 23 25 CARBURETOR ADJUSTMENT 23 26 REPLACING FUEL FILTER SEE FIG 23 24 27 DRAINING FUEL TANK AND CARBURETOR 24 27 1 Draining the fuel tank 24 27 2 Draining t...

Page 5: ...FG6250P E FG7750P E FG9250P E EN Copyright 2016 P a g e 5 www fordpowerequipment co uk 35 2 Maintenance Fout Bladwijzer niet gedefinieerd 36 SERVICE 30...

Page 6: ...hting or serve as a back up power source during power outages It is not designed for professional use WARNING Please read and understand this operating manual before use and keep it for your future re...

Page 7: ...t Guide 1 Spark Plug Wrench 1 Toolkit Phillips screwdriver 1 Combination Wrench 2 Funnel 1 Handles 2 Bushings Flanged 4 Outlets 3 Description Qty M8 x 50mm Hex Bolts for Handle 2 M8 Flanged Nuts for H...

Page 8: ...pen Install a battery operated carbon monoxide alarm near bedrooms Keep exhaust from this unit from entering a confined area through windows doors vents or other openings When working in areas where v...

Page 9: ...ank is empty with the fuel shut off valve turned to the off position WARNING Pull cord recoils rapidly and pulls arm towards engine faster than you can let go which could result in injury To avoid rec...

Page 10: ...t rated frequency and voltage WARNING Only use this unit as intended or serious injury or death could result Do not bypass any safety device Moving parts are covered with guards Make sure all protecti...

Page 11: ...es 2 hair pins 2 washers 2 hub caps and 2 self tapping screws Raise or tilt generator so you can slide the wheel axle pin into the wheel the washer the wheel mounting hole located on the side of the f...

Page 12: ...through the eyelet and tighten the screw and make sure the terminal will not touch any part of the frame Install the Red protection boot Fig 4 Repeat these steps for the Black Terminal WARNING Be car...

Page 13: ...6250P E FG7750P E FG9250P E EN Copyright 2016 P a g e 13 www fordpowerequipment co uk 6 5 Installing the handles Fig 5 Fig 5 6 6 Recoil starting Fig 6 Attach the Recoil Starter Grip to the bracket Fig...

Page 14: ...Wear Eye Protection Never Reverse Pole Connections Never turn the battery upside down DO NOT Smoke near the battery If electrolyte contacts the skin wash the area immediately with clean water If you...

Page 15: ...vide space for fuel expansion Fig 8 CAUTION You must add oil before first operating this generator Always check oil level before each operation DO NOT USE E15 OR E85 FUEL IN THIS UNIT IT IS A VIOLATIO...

Page 16: ...s Fig 9 WARNING Generator must be properly grounded to prevent electrocution Only operate generator on a level surface Always connect the nut and ground terminal on the frame to an appropriate ground...

Page 17: ...Pull cord recoils rapidly and pulls arm towards engine faster than you can let go which could result in injury To avoid recoil pull starter cord slowly until resistance is felt then pull rapidly fig 1...

Page 18: ...enerator must be carried fold handle to the down position Never lift or carry generator by its handle CAUTION This product is heavy and requires several people to lift Lift and lower with your legs by...

Page 19: ...oltage V displays the operating voltage of the generator Frequency F displays the frequency in hertz at which the generator is running The Run Maintenance Timer displays the time in hours and minutes...

Page 20: ...heat created by the generator to prevent icing 1 Cut off all flaps 2 Cut off one of the long sides of the carton to expose the units muffler and exhaust Do not enclose the muffler exhaust 3 side of t...

Page 21: ...lent Service Fuel Valve Inspect Muffler and Spark Arrester Check and Clean Air Cleaner Replace Air Filter Clean Cooling System 19CHANGING OIL SEE FIG 19 Run the Generator until the Engine is warm Plac...

Page 22: ...ity for the engine Use the chart to select the best viscosity for the outdoor temperature range expected Note Below 40 F 4 C the use of SAE 30 will result in hard starting Above 80 F 27 C the use of 1...

Page 23: ...nd slowly adjust to 0 700 mm 0 800 mm 028 031 if necessary Reinstall spark plug and tighten to Torque 22 0 26 9 Nm 16 20 ft lb Reconnect spark plug wire If spark plug is worn replace only with an equi...

Page 24: ...ior to fill up Fig 22 Fig 23 27DRAINING FUEL TANK AND CARBURETOR To help prevent gum deposits in the fuel system drain the fuel from the tank and carburetor before storing the unit for long periods of...

Page 25: ...ris if obstructed For short term storage start generator once every 7 days For semi long term storage add fuel stabilizer to prevent stale fuel from causing acid and gum deposits in the fuel system an...

Page 26: ...500W 6500W 7500W Voltage 110V 230 240V AC Engine 420cc OHV 4 Stroke Air Cooled Engine Oil 10W30 1L Fuel Tank 25L Unleaded Gasoline 31NOISE Noise values measured according to relevant standard K 3 FG62...

Page 27: ...cted from spark plug 6 Bad spark plug 7 Water in fuel 8 Fuel valve is in OFF position 9 Over choking 10 Low oil level 11 Rich fuel mixture 12 Intake valve stuck open or closed 13 Loss of engine compre...

Page 28: ...ment co uk 33ELECTRICAL DIAGRAM RECOIL STARTER TYPE Alternator Alternator control panel control panel Engine Engine Engine switch connecting Bl Black Br Brown Y G Yellow Green 0 Orange Br R Brown Red...

Page 29: ...ment co uk 34ELECTRICAL DIAGRAM ELECTRIC START TYPE Alternator Alternator control panel control panel Engine Engine Engine switch connecting Bl Black Br Brown Y G Yellow Green 0 Orange Br R Brown Red...

Page 30: ...CE How to contact us To order parts receive warranty assistance or other services inquiries you can contact us by Please see contact data on the back of this manual Record the following information be...

Reviews: